Literature DB >> 9066428

Prevention of air leaks after pulmonary wedge resection.

C C Vaughn1, E Wolner, M Dahan, D Grunenwald, C C Vaughn1, W Klepetko, M Filaire, P L Vaughn, R A Baratz.   

Abstract

Prolonged air leak after a lung volume reduction operation for pulmonary emphysema is a major cause of morbidity and prolonged hospital stay. Staple line reinforcement is recognized as an effective adjunctive technique for decreasing the occurrence of air leaks after pulmonary wedge resection. Numerous materials have been used for staple-line reinforcement. We use expanded polytetrafluoroethylene sleeves that fit over the arms of surgical staplers to facilitate staple-line reinforcement in both thoracoscopic and open lung volume reduction procedures. The expanded polytetrafluoroethylene sleeves do not require rinsing or special handling; they are easy to use and effective in preventing air leaks. We had no prolonged air leaks or infections in any of the cases in which we used the sleeves.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9066428     DOI: 10.1016/s0003-4975(96)01151-4

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  6 in total

1.  Efficacy and effectiveness of suture bolster with Seamguard.

Authors:  Raffaele Pugliese; Dario Maggioni; Fabio Sansonna; Giovanni Carlo Ferrari; Stefano Di Lernia; Antonello Forgione; Carmelo Magistro
Journal:  Surg Endosc       Date:  2009-02-28       Impact factor: 4.584

2.  Decreasing anastomotic and staple line leaks after laparoscopic Roux-en-Y gastric bypass.

Authors:  Terrence M Fullum; Kanaychukwu J Aluka; Patricia L Turner
Journal:  Surg Endosc       Date:  2009-03-05       Impact factor: 4.584

3.  The effect of mesh reinforcement of a stapled transection line on the rate of pancreatic occlusion failure after distal pancreatectomy: review of a single institution's experience.

Authors:  Fabian Mc Johnston; Antonino Cavataio; Steven M Strasberg; Nicholas A Hamilton; Peter O Simon; Kathryn Trinkaus; M B Majella Doyle; Brent D Mathews; Matthew R Porembka; David C Linehan; William G Hawkins
Journal:  HPB (Oxford)       Date:  2009-02       Impact factor: 3.647

4.  Absorbable mesh reinforcement of a stapled pancreatic transection line reduces the leak rate with distal pancreatectomy.

Authors:  Reuben I Thaker; Brent D Matthews; David C Linehan; Steven M Strasberg; J Chris Eagon; William G Hawkins
Journal:  J Gastrointest Surg       Date:  2007-01       Impact factor: 3.452

5.  Double stapling method for closure of intraoperative alveolar air leakage adjacent to the staple line: a randomized experimental study on ex vivo porcine lungs.

Authors:  Takahiro Suzuki; Keisuke Asakura; Takumi Egawa; Masahiro Kawauchi; Yu Okubo; Kyohei Masai; Kaoru Kaseda; Tomoyuki Hishida; Hisao Asamura
Journal:  J Thorac Dis       Date:  2022-06       Impact factor: 3.005

6.  Clinical outcomes of pre-attached reinforced stapler reloads in thoracic surgery: a prospective case series.

Authors:  Eric Lim; Jean-Marc Baste; Michael Shackcloth
Journal:  J Thorac Dis       Date:  2022-08       Impact factor: 3.005

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.