A relatively atraumatic, simple and very reliable method of retrieving the proximal end of a severed flexor tendon of a finger or thumb is described. The technique involves passing a Silastic feeding tube into the flexor tendon sheath, placing the retracted tendon within its lumen, and securing it in place with a single stitch. The feeding tube is then withdrawn until the tendon presents within the distal wound. Hypodermic needle fixation and tendon repair is then carried out in the usual manner.Mesh:
Year: 1997 PMID: 9061546 DOI: 10.1016/s0266-7681(97)80037-x
Source DB: PubMed Journal: J Hand Surg Br ISSN: 0266-7681