Literature DB >> 30205719

The Flexor Pollicis Longus Tendon Does Not Lie Parallel to the Thumb Metacarpal.

Jonathan Lans1, Jan Jonas van Hernen1, Beatriz Eusamio1, Chris Langhammer1, Kyle R Eberlin1, Neal C Chen1.   

Abstract

BACKGROUND: Repair of the flexor pollicis longus (FPL) tendon by tendon retriever can be challenging because of uncertainty of the optimal direction. This study aims to describe the FPL tendon path in the thenar eminence.
METHODS: In 18 hands of 9 cadavers, the angle of the FPL tendon was, after dissection, measured in relation to the axis formed between the metacarpophalangeal (MCP) joint of the thumb and the dorsal carpometacarpal joint (MC1-axis) and the axis formed between the second MCP joint and the distal edge of the trapezium (MC2-axis).
RESULTS: The FPL does not follow the angle of the thumb metacarpal. The FPL runs ulnarly from the MC1-axis at a median of 32.5° in abduction and 30.6° in adduction. In relation to the MC2-axis, it runs at a median of 47.5° in abduction and 25° in adduction.
CONCLUSIONS: The FPL tendon path can be preoperatively marked using: (1) the MC1-axis from which it runs ulnarly approximately at an angle of 30° in both abduction and adduction; or (2) the MC2-axis from which it runs radially at an angle of 47.5° in abduction and at an angle of 25° in adduction. We conclude that the FPL tendon path can be preoperatively marked using these axes and does not parallel the metacarpal axes of the thumb.

Entities:  

Keywords:  flexor pollicis longus; flexor tendon injury; hand anatomy

Mesh:

Year:  2018        PMID: 30205719      PMCID: PMC6346359          DOI: 10.1177/1558944718798852

Source DB:  PubMed          Journal:  Hand (N Y)        ISSN: 1558-9447


  17 in total

1.  A simple, semirigid, and surgeon-friendly tendon retriever and flexor sheath dilator.

Authors:  B Jagannath Kamath; Praveen Bhardwaj
Journal:  J Hand Surg Am       Date:  2007-02       Impact factor: 2.230

2.  A modification of the catheter method for retrieval of divided flexor tendons.

Authors:  O G Titley
Journal:  J Hand Surg Br       Date:  1996-06

3.  The flexor pollicis longus and its relation to the anterior and posterior interosseous nerves.

Authors:  S Shirali; M Hanson; G Branovacki; M Gonzalez
Journal:  J Hand Surg Br       Date:  1998-04

4.  A further tendon retrieval trick.

Authors:  M J Sandow
Journal:  J Hand Surg Br       Date:  1997-02

5.  A relatively atraumatic method of retrieving retracted digital flexor tendons.

Authors:  A Adeniran; A Z Babar
Journal:  J Hand Surg Br       Date:  1997-02

6.  Varied anatomy of the thumb pulley system: implications for successful trigger thumb release.

Authors:  Manuel F Schubert; Vandan S Shah; Clifford L Craig; John L Zeller
Journal:  J Hand Surg Am       Date:  2012-11       Impact factor: 2.230

7.  Retrieval of the retracted flexor tendon.

Authors:  S G Sourmelis; D A McGrouther
Journal:  J Hand Surg Br       Date:  1987-02

8.  Retrieval of the retracted flexor tendon.

Authors:  M K Abouzahr
Journal:  Plast Reconstr Surg       Date:  1995-08       Impact factor: 4.730

9.  The use of skin hooks and hypodermic needles in tendon surgery.

Authors:  R J Morris; D L Martin
Journal:  J Hand Surg Br       Date:  1993-02

10.  The prevalence and anatomical characteristics of the accessory head of the flexor pollicis longus muscle: a meta-analysis.

Authors:  Joyeeta Roy; Brandon M Henry; Przemysław A Pękala; Jens Vikse; Piravin Kumar Ramakrishnan; Jerzy A Walocha; Krzysztof A Tomaszewski
Journal:  PeerJ       Date:  2015-10-01       Impact factor: 2.984

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.