Literature DB >> 9061143

Phosphorylcholine coating of ePTFE grafts reduces neointimal hyperplasia in canine model.

C Chen1, A B Lumsden, J C Ofenloch, B Noe, E J Campbell, P W Stratford, Y P Yianni, A S Taylor, S R Hanson.   

Abstract

This study attempts to prevent neointimal hyperplasia by coating the graft luminal surface with a derivative of phosphorylcholine (PC), thereby providing a biocompatible surface with the assumption of limiting pannus tissue ingrowth from the graft anastomoses. Bilateral carotid artery bypass grafts were placed in six dogs using expanded polytetrafluoroethylene (ePTFE). In each animal, one carotid arterial-arterial conduit was constructed using a graft having a PC coating over the entire luminal surface of the graft. On the contralateral side, uncoated graft served as a control. The processed specimens were analyzed for graft neointimal area and neointimal thickness. Cell proliferation was assessed by staining for bromodeoxyuridine (BrdU) incorporation. All grafts were patent except one control graft that was occluded at 4 weeks. There was a significant reduction in the anastomotic graft neointimal area between the treated and control groups (0.27 +/- 0.17 mm2 versus 0.53 +/- 0.13 mm2, respectively; p = 0.008). Furthermore, the BrdU labeling index in the graft neointimal tissues was significantly smaller (p < 0.001) in the treated group (2.64 +/- 0.77%) as compared with the control group (5.07 +/- 0.83%). These data demonstrate that PC coating of ePTFE significantly reduces graft neointimal hyperplasia and cell proliferation in a canine carotid artery bypass model. The application of PC within the ePTFE graft effectively blocks tissue ingrowth from the adjacent native vessel, thereby preserving the anastomosis luminal diameter.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9061143     DOI: 10.1007/s100169900013

Source DB:  PubMed          Journal:  Ann Vasc Surg        ISSN: 0890-5096            Impact factor:   1.466


  10 in total

1.  Biocompatibility of phosphorylcholine coated stents in normal porcine coronary arteries.

Authors:  D M Whelan; W J van der Giessen; S C Krabbendam; E A van Vliet; P D Verdouw; P W Serruys; H M van Beusekom
Journal:  Heart       Date:  2000-03       Impact factor: 5.994

Review 2.  New advances in endovascular technology.

Authors:  J C Palmaz
Journal:  Tex Heart Inst J       Date:  1997

3.  In-vitro thrombogenicity assessment of flow diversion and aneurysm bridging devices.

Authors:  Gaurav Girdhar; Junwei Li; Larisa Kostousov; John Wainwright; Wayne L Chandler
Journal:  J Thromb Thrombolysis       Date:  2015-11       Impact factor: 2.300

4.  Significant correlation between ankle-brachial index and vascular access failure in hemodialysis patients.

Authors:  Szu-Chia Chen; Jer-Ming Chang; Shang-Jyh Hwang; Jer-Chia Tsai; Chuan-Sheng Wang; Hsiu-Chin Mai; Feng-Hsien Lin; Ho-Ming Su; Hung-Chun Chen
Journal:  Clin J Am Soc Nephrol       Date:  2009-01       Impact factor: 8.237

5.  Engineering an endothelialized vascular graft: a rational approach to study design in a non-human primate model.

Authors:  Deirdre E J Anderson; Jeremy J Glynn; Howard K Song; Monica T Hinds
Journal:  PLoS One       Date:  2014-12-19       Impact factor: 3.240

6.  Thrombogenicity of flow diverters in an ex vivo shunt model: effect of phosphorylcholine surface modification.

Authors:  Matthew W Hagen; Gaurav Girdhar; John Wainwright; Monica T Hinds
Journal:  J Neurointerv Surg       Date:  2016-10-31       Impact factor: 5.836

7.  An Increase in Mean Platelet Volume/Platelet Count Ratio Is Associated with Vascular Access Failure in Hemodialysis Patients.

Authors:  Dong Ho Shin; So Yon Rhee; Hee Jung Jeon; Ji-Young Park; Shin-Wook Kang; Jieun Oh
Journal:  PLoS One       Date:  2017-01-17       Impact factor: 3.240

8.  Analysis of neointima development in flow diverters using optical coherence tomography imaging.

Authors:  Yoshikazu Matsuda; Joonho Chung; Demetrius K Lopes
Journal:  J Neurointerv Surg       Date:  2017-06-07       Impact factor: 5.836

9.  Prospective study to assess the tissue response to HPC-coated p48 flow diverter stents compared to uncoated devices in the rabbit carotid artery model.

Authors:  Tim Lenz-Habijan; Pervinder Bhogal; Catrin Bannewitz; Ralf Hannes; Hermann Monstadt; Andreas Simgen; Ruben Mühl-Benninghaus; Wolfgang Reith; Hans Henkes
Journal:  Eur Radiol Exp       Date:  2019-12-05

10.  Hydrophilic Stent Coating Inhibits Platelet Adhesion on Stent Surfaces: Initial Results In Vitro.

Authors:  Tim Lenz-Habijan; P Bhogal; Marcus Peters; Albrecht Bufe; Rosa Martinez Moreno; Catrin Bannewitz; Hermann Monstadt; Hans Henkes
Journal:  Cardiovasc Intervent Radiol       Date:  2018-07-23       Impact factor: 2.740

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.