Literature DB >> 9059272

Diurnal variations in human corneal thickness.

C L Harper1, M E Boulton, D Bennett, B Marcyniuk, J H Jarvis-Evans, A B Tullo, A E Ridgway.   

Abstract

AIM: To elucidate the diurnal variation in human corneal thickness over a 48 hour period.
METHOD: Changes in central corneal thickness were monitored in eight healthy subjects (four male, four female) aged between 10 and 63 years using an ultrasonic pachymeter. Measurements were made over a 48 hour period-immediately before sleep, immediately upon waking and at 15, 30, 45 minutes, 1, 1.5, 2, 2.5, 3 hours, and at 2 hour intervals thereafter throughout the remainder of each day.
RESULTS: The mean corneal thickness for the group (SD) was 546 (14) microns, with a mean overnight increase of 5.5% (2.9%) (range 1.9-12.6%) and a maximum diurnal increase of 7.2% (2.8%) (range 2.1-14.3%). Individual differences in the extent of diurnal and overnight variation occurred within the group. For three subjects, the first reading taken on waking was not the highest and corneal thickness continued to increase.
CONCLUSION: These data confirm an increase of corneal thickness during sleep, but also reveal considerable variation during waking hours. Thus, the overnight changes in corneal thickness are not truly representative of diurnal variations in human corneal thickness and, in fact, much greater diurnal variation occurs than the 3.0-4.4% previously reported.

Entities:  

Mesh:

Year:  1996        PMID: 9059272      PMCID: PMC505705          DOI: 10.1136/bjo.80.12.1068

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  22 in total

1.  Effect of humidity on the deswelling function of the human cornea.

Authors:  S Bourassa; W J Benjamin; R L Boltz
Journal:  Curr Eye Res       Date:  1991-06       Impact factor: 2.424

2.  Corneal hydration control in Fuchs' dystrophy.

Authors:  R B Mandell; K A Polse; R J Brand; D Vastine; D Demartini; R Flom
Journal:  Invest Ophthalmol Vis Sci       Date:  1989-05       Impact factor: 4.799

3.  Positive correlation of corneal thickness and endothelial cell loss. Serial measurements after cataract surgery.

Authors:  H Cheng; A K Bates; L Wood; K McPherson
Journal:  Arch Ophthalmol       Date:  1988-07

4.  Corneal thinning syndromes.

Authors:  M S Insler; J D Baumann
Journal:  Ann Ophthalmol       Date:  1986-02

5.  Diurnal variation of intraocular pressure and the overriding effects of sleep.

Authors:  P Frampton; D Da Rin; B Brown
Journal:  Am J Optom Physiol Opt       Date:  1987-01

6.  Thinning of the human cornea on awakening.

Authors:  R B Mandell; I Fatt
Journal:  Nature       Date:  1965-10-16       Impact factor: 49.962

7.  Temporary corneal oedema after acute intake of alcohol.

Authors:  T Shiono; Y Asano; T Hashimoto; K Mizuno
Journal:  Br J Ophthalmol       Date:  1987-06       Impact factor: 4.638

8.  Corneal hydration control in diabetes mellitus.

Authors:  B C Weston; W M Bourne; K A Polse; D O Hodge
Journal:  Invest Ophthalmol Vis Sci       Date:  1995-03       Impact factor: 4.799

9.  Corneal thickness changes following sleep and overnight contact lens wear in the primate (Macaca fascicularis).

Authors:  M C Madigan; S Gillard-Crewther; P M Kiely; D P Crewther; N A Brennan; N Efron; B A Holden
Journal:  Curr Eye Res       Date:  1987-06       Impact factor: 2.424

10.  Contact lens-induced edema in vitro. Pharmacology and metabolic considerations.

Authors:  J W Huff
Journal:  Invest Ophthalmol Vis Sci       Date:  1991-02       Impact factor: 4.799

View more
  35 in total

1.  Corneal thickness and endothelial density before and after cataract surgery.

Authors:  A C Ventura; R Wälti; M Böhnke
Journal:  Br J Ophthalmol       Date:  2001-01       Impact factor: 4.638

2.  Intraobserver and interobserver reproducibility in the evaluation of ultrasonic pachymetry measurements of central corneal thickness.

Authors:  S Miglior; E Albe; M Guareschi; G Mandelli; S Gomarasca; N Orzalesi
Journal:  Br J Ophthalmol       Date:  2004-02       Impact factor: 4.638

3.  Diurnal variations of central corneal thickness and intraocular pressure in dogs from 8:00 am to 8:00 pm.

Authors:  Eva Martín-Suárez; Carolina Molleda; Rodrigo Tardón; Alba Galán; José Gallardo; José Molleda
Journal:  Can Vet J       Date:  2014-04       Impact factor: 1.008

4.  Is there any association between primary hyperparathyroidism and ocular changes, such as central corneal thickness, retinal thickness, and intraocular pressure?

Authors:  Husniye Baser; Neslihan Cuhaci; Oya Topaloglu; Fatma Yulek; Nagihan Ugurlu; Reyhan Ersoy; Nurullah Cagil; Bekir Cakir
Journal:  Endocrine       Date:  2015-08-29       Impact factor: 3.633

5.  Comparison of clear corneal incision injuries between torsional and conventional phacoemulsification.

Authors:  Xu Chen; Yinghong Ji; Yi Lu
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-07-20       Impact factor: 3.117

6.  Circadian variations in central corneal thickness and intraocular pressure in patients with glaucoma.

Authors:  P Fogagnolo; L Rossetti; F Mazzolani; N Orzalesi
Journal:  Br J Ophthalmol       Date:  2006-01       Impact factor: 4.638

7.  Effects of Corneal Hydration on Brillouin Microscopy In Vivo.

Authors:  Peng Shao; Theo G Seiler; Amira M Eltony; Antoine Ramier; Sheldon J J Kwok; Giuliano Scarcelli; Roberto Pineda Ii; Seok-Hyun Yun
Journal:  Invest Ophthalmol Vis Sci       Date:  2018-06-01       Impact factor: 4.799

8.  Quantitative trait loci associated with murine central corneal thickness.

Authors:  Geoffrey D Lively; Demelza Koehn; Adam Hedberg-Buenz; Kai Wang; Michael G Anderson
Journal:  Physiol Genomics       Date:  2010-04-27       Impact factor: 3.107

9.  Reproducibility of Central Corneal Thickness Measurements in Healthy and Glaucomatous Eyes.

Authors:  Tony Realini; Matthew J Gurka; Robert N Weinreb
Journal:  J Glaucoma       Date:  2017-09       Impact factor: 2.503

10.  South African Eye Study (SAES): ethnic differences in central corneal thickness and intraocular pressure.

Authors:  S O Baboolal; D P Smit
Journal:  Eye (Lond)       Date:  2018-01-12       Impact factor: 3.775

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.