Literature DB >> 9055222

Time-resolved projection angiography after bolus injection of contrast agent.

J Hennig1, K Scheffler, J Laubenberger, R Strecker.   

Abstract

A method for MR angiography after bolus injection of a normal dose (0.1 mmol/kg) of contrast agent is presented. Projection angiograms are acquired with a non-slice selective Snapshot FLASH sequence with a time resolution of 1 s per image or better. Typically 40 to 60 images are acquired consecutively after bolus injection of a contrast agent. The signal from vessels can be separated from background by postprocessing based on the observed temporal evolution of the signal intensities during bolus passage. The subsecond projection MR-DSA is a reliable and robust technique to produce high resolution anatomical images of the vascular system avoiding the necessity of exact timing of the contrast agent bolus. It also supplies functional information about the hemodynamics in the observed region including perfusion.

Mesh:

Substances:

Year:  1997        PMID: 9055222     DOI: 10.1002/mrm.1910370306

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  28 in total

Review 1.  Contrast-enhanced pulmonary MR imaging.

Authors:  O Haraldseth; T Amundsen; P A Rinck
Journal:  MAGMA       Date:  1999-08       Impact factor: 2.310

2.  Functional MRA.

Authors:  J Hennig; R Strecker
Journal:  MAGMA       Date:  2000-11       Impact factor: 2.310

3.  The emergence of time-resolved contrast-enhanced MR imaging for intracranial angiography.

Authors:  Timothy J Carroll
Journal:  AJNR Am J Neuroradiol       Date:  2002-03       Impact factor: 3.825

Review 4.  Neurovascular MRI with dynamic contrast-enhanced subtraction angiography.

Authors:  S C Coley; J M Wild; I D Wilkinson; P D Griffiths
Journal:  Neuroradiology       Date:  2003-09-20       Impact factor: 2.804

Review 5.  MR-guided endovascular interventions: a comprehensive review on techniques and applications.

Authors:  Sebastian Kos; Rolf Huegli; Georg M Bongartz; Augustinus L Jacob; Deniz Bilecen
Journal:  Eur Radiol       Date:  2007-12-11       Impact factor: 5.315

6.  Dynamic CT angiography and CT perfusion employing a 320-detector row CT: protocol and current clinical applications.

Authors:  Eric J Salomon; Joe Barfett; Peter W A Willems; Sasikhan Geibprasert; Susanna Bacigaluppi; Timo Krings
Journal:  Klin Neuroradiol       Date:  2009-08-23

7.  Reliability and accuracy of time-resolved contrast-enhanced magnetic resonance angiography in hypervascular spinal metastases prior embolization.

Authors:  Kévin Premat; Eimad Shotar; Robert Burns; Natalia Shor; Gauthier Eloy; Évelyne Cormier; Mehdi Drir; Laetitia Morardet; Stéphanie Lenck; Nader Sourour; Jacques Chiras; Didier Dormont; Raphaël Bonaccorsi; Frédéric Clarençon
Journal:  Eur Radiol       Date:  2021-01-15       Impact factor: 5.315

8.  Dynamic contrast enhancement of paragangliomas of the head and neck: evaluation with time-resolved 2D MR projection angiography.

Authors:  Sebastian M Arnold; Ralph Strecker; Klaus Scheffler; Joachim Spreer; Jörg Schipper; Hartmut P H Neumann; Joachim Klisch
Journal:  Eur Radiol       Date:  2002-11-01       Impact factor: 5.315

9.  Time-resolved 3D contrast-enhanced MRA with GRAPPA on a 1.5-T system for imaging of craniocervical vascular disease: initial experience.

Authors:  Stephan Meckel; Ralf Mekle; Christian Taschner; Sven Haller; Klaus Scheffler; Ernst-Wilhelm Radue; Stephan G Wetzel
Journal:  Neuroradiology       Date:  2006-03-11       Impact factor: 2.804

10.  Pediatric head and neck lesions: assessment of vascularity by MR digital subtraction angiography.

Authors:  Weng Kong Chooi; Neil Woodhouse; Stuart C Coley; Paul D Griffiths
Journal:  AJNR Am J Neuroradiol       Date:  2004-08       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.