Literature DB >> 9054755

Long-term follow-up of cardioverter-defibrillator implanted under conscious sedation in prepectoral subfascial position.

A Pacifico1, K R Wheelan, N Nasir, P J Wells, T K Doyle, S A Johnson, P D Henry.   

Abstract

BACKGROUND: Implantable cardioverter-defibrillators (ICDs) with intravenous electrode systems and downsized generators can be implanted by use of operative techniques similar to those employed for the insertion of permanent pacemakers. However, the safety, efficacy, and long-term follow-up of simplified implantation procedures remain to be evaluated. This report is a prospective long-term evaluation of nonselected patients receiving ICDs in the prepectoral subfascial position under conscious sedation. METHODS AND
RESULTS: Clinical characteristics of the 231 consecutive patients included a mean age of 63 years, a male-to-female ratio of 6.4, a left ventricular ejection fraction of 0.34, a mild-to-moderate heart failure in 91%, coronary artery disease in 84%, and a history of aborted sudden cardiac death or refractory ventricular tachyarrhythmias. Insertion of transvenous leads and prepectoral subfascial ICD implantation were performed in electrophysiology laboratories under local anesthesia and conscious sedation with intravenous midazolam and propofol. Successful implantation in all patients (operation time, 80 +/- 32 minutes, mean +/- SD) irrespective of body size and skin thickness was free of major complications, including need for emergency intubation. After surgery, 1 pocket hematoma, 1 seroma, and 1 pneumothorax required treatment. There was no operative or first-month mortality. During long-term follow-up averaging 453 +/- 296 days, six leads required repositioning, but pocket erosions or infections did not occur. First-year total survival was 97%.
CONCLUSIONS: Implantation under conscious sedation of ICDs in the prepectoral subfascial position is a safe and effective procedure with low operative and postoperative morbidity and favorable long-term outcome.

Entities:  

Mesh:

Year:  1997        PMID: 9054755     DOI: 10.1161/01.cir.95.4.946

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  9 in total

1.  A comparison of pectoral and abdominal transvenous defibrillator implantation: analysis of costs and outcomes.

Authors:  M R Gold; D Froman; N G Kavesh; R W Peters; A H Foster; S R Shorofsky
Journal:  J Interv Card Electrophysiol       Date:  1998-12       Impact factor: 1.900

Review 2.  [Implantation of cardioverter-defibrillators. How much anesthesia is necessary?].

Authors:  T Sellmann; M Winterhalter; U Herold; P Kienbaum
Journal:  Anaesthesist       Date:  2010-06       Impact factor: 1.041

3.  Effects of propofol sedation on pacing thresholds : Results from an observational cohort study.

Authors:  Jakob Lüker; Arian Sultan; Tobias Plenge; Samuel Lee; Jan-Hendrik van den Bruck; Daniel Steven
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2017-11-14

4.  Subpectoral cardioverter-defibrillator implantation using a lateral approach.

Authors:  X F Costeas; P G Strembelas; D X Markou; C I Stefanadis; P K Toutouzas
Journal:  J Interv Card Electrophysiol       Date:  2000-12       Impact factor: 1.900

5.  Endovascular extraction techniques: Part 3: Results and indications in patients with an ICD.

Authors:  F A Bracke; A Meijer; B van Gelder
Journal:  Neth Heart J       Date:  2001-06       Impact factor: 2.380

6.  Intravenous sedation for cardiac procedures can be administered safely and cost-effectively by non-anesthesia personnel.

Authors:  Anna Kezerashvili; John D Fisher; Jessica DeLaney; Savi Mushiyev; Eileen Monahan; Vanessa Taylor; Soo G Kim; Kevin J Ferrick; Jay N Gross; Eugen C Palma; Andrew K Krumerman
Journal:  J Interv Card Electrophysiol       Date:  2008-02-14       Impact factor: 1.900

7.  Complications and mortality of single versus dual chamber implantable cardioverter defibrillators.

Authors:  Ataallah Bagherzadeh; Zahra Emkanjoo; Majid Haghjoo; Maryam Moshkani Farahani; Abolfath Alizadeh; Mohammad Ali Sadr-Ameli
Journal:  Indian Pacing Electrophysiol J       Date:  2006-04-01

8.  Efficacy and feasibility of the submuscular implantation technique for an implantable cardiac electrical device.

Authors:  Shinichi Asamura; Takashi Kurita; Koichiro Motoki; Ryobun Yasuoka; Takahiro Hashimoto; Noritaka Isogai
Journal:  Eplasty       Date:  2014-10-30

Review 9.  Perioperative management for the prevention of bacterial infection in cardiac implantable electronic device placement.

Authors:  Katsuhiko Imai
Journal:  J Arrhythm       Date:  2015-08-08
  9 in total