Literature DB >> 9052536

Primary total hip arthroplasty with a porous-coated acetabular component. Seven-to-ten-year results.

G S Tompkins1, J J Jacobs, L R Kull, A G Rosenberg, J O Galante.   

Abstract

One hundred and eighty-four patients who had been managed, between 1984 and 1985, with a total of 204 consecutive primary total hip arthroplasties with insertion of a Harris-Galante type-I acetabular component without cement were prospectively studied. There were eighty-two men (45 per cent) and 102 women (55 per cent). The mean age at the time of the operation was fifty-two years (range, twenty to eighty-four years). One hundred and fifty-seven patients (173 hips) were available for clinical review at a mean of 104 months (range, seventy-eight to 126 months). At this time, the mean preoperative Harris hip score of 52 points (range, 12 to 79 points) had improved to a mean of 90 points (range, 44 to 100 points). Two patients (two hips) had an exchange of an excessively worn polyethylene liner. One patient (one hip) had debridement and grafting of an area of massive retroacetabular osteolysis. Two stable acetabular components (1 per cent) had been revised at the time of femoral revision. None of the cups had been revised because of aseptic loosening. Radiographic examination of 150 patients (165 hips) at a mean of 104 months (range, seventy-eight to 126 months) revealed that 156 cups (95 per cent) were stable. Eight cups (5 per cent) were considered to be possibly unstable, with a radiolucent line between the prosthesis and the bone that was one millimeter wide or less in at least four of five zones; two of the eight had a complete radiolucent line in all zones. One component, which had been implanted with a bulk allograft from a femoral head, migrated more than two millimeters in the first two years and then stabilized without complication. Osteolysis was seen in seven acetabula (4 per cent) and was limited to the periphery of the cup in six. Survivorship analysis at ten years revealed that the acetabular component had a 99 per cent chance of survival (95 per cent confidence interval, 0.98 to 1.0) with revision or aseptic loosening as the end point and a 97 per cent chance of survival (95 per cent confidence interval, 0.95 to 1.0) with revision, aseptic loosening, or reoperation because of a problem related to the acetabular component as the end point.

Entities:  

Mesh:

Year:  1997        PMID: 9052536     DOI: 10.2106/00004623-199702000-00002

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  12 in total

1.  Early polyethylene wear and osteolysis with ABG acetabular cups (7- to 12-year follow-up).

Authors:  Sachin Badhe; Peter Livesley
Journal:  Int Orthop       Date:  2005-11-08       Impact factor: 3.075

2.  Polyethylene Liner Dissociation Is a Complication of the DePuy Pinnacle Cup: A Report of 23 Cases.

Authors:  Andrew Yun; Emmanuel N Koli; John Moreland; Richard Iorio; John F Tilzey; J Wesley Mesko; Gwo-Chin Lee; Mark Froimson
Journal:  Clin Orthop Relat Res       Date:  2016-02       Impact factor: 4.176

3.  Successful long-term fixation and progression of osteolysis associated with first-generation cementless acetabular components retrieved post mortem.

Authors:  Robert M Urban; Deborah J Hall; Craig Della Valle; Markus A Wimmer; Joshua J Jacobs; Jorge O Galante
Journal:  J Bone Joint Surg Am       Date:  2012-10-17       Impact factor: 5.284

Review 4.  Hip resurfacing versus total hip arthroplasty: a systematic review comparing standardized outcomes.

Authors:  Deborah A Marshall; Karen Pykerman; Jason Werle; Diane Lorenzetti; Tracy Wasylak; Tom Noseworthy; Donald A Dick; Greg O'Connor; Aish Sundaram; Sanne Heintzbergen; Cy Frank
Journal:  Clin Orthop Relat Res       Date:  2014-04-04       Impact factor: 4.176

5.  Wear-corrosion synergism in a CoCrMo hip bearing alloy is influenced by proteins.

Authors:  Mathew T Mathew; Joshua J Jacobs; Markus A Wimmer
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

6.  Direct comparison of polyethylene wear in cemented and uncemented acetabular cups.

Authors:  Håvard Bjerkholt; Oystein Høvik; Olav Reikerås
Journal:  J Orthop Traumatol       Date:  2010-09-02

Review 7.  Early proximal migration of cups is associated with late revision in THA: a systematic review and meta-analysis of 26 RSA studies and 49 survivalstudies.

Authors:  Bart G Pijls; Marc J Nieuwenhuijse; Marta Fiocco; Josepha Wm Plevier; Saskia Middeldorp; Rob Ghh Nelissen; Edward R Valstar
Journal:  Acta Orthop       Date:  2012-11-05       Impact factor: 3.717

8.  Retrieval analysis of Harris-Galante I and II acetabular liners in situ for more than 10 years.

Authors:  Keisha French; Rebecca Moore; Heather Gawel; Steven M Kurtz; Matthew J Kraay; Ke Xie; Victor M Goldberg; Clare M Rimnac
Journal:  Acta Orthop       Date:  2012-08-10       Impact factor: 3.717

9.  Failure of dual radius hydroxyapatite-coated acetabular cups.

Authors:  Fabio D'Angelo; Mauro Molina; Giacomo Riva; Giovanni Zatti; Paolo Cherubino
Journal:  J Orthop Surg Res       Date:  2008-08-07       Impact factor: 2.359

10.  Total hip arthroplasty for intertrochanteric fracture fixation failure.

Authors:  Liyun Liu; Yongqiang Sun; Linlin Wang; Qiankun Gao; Ang Li; Jialin Wang; Yanzheng Gao
Journal:  Eur J Med Res       Date:  2019-12-27       Impact factor: 2.175

View more