Verification of radiosurgery target point alignment with an electronic portal imaging device (EPID).

L Dong1, A Shiu, S Tung, A Boyer.   

Abstract

A procedure has been developed using an electronic portal imaging device (EPID) to verify that the center of a patient's lesion is aligned with the center of a treatment cone prior to treatment in a linac-based stereotactic radiosurgery procedure. The coordinates of the lesion center are set on the Brown-Roberts-Wells phantom base using a target simulator. A 3 mm tungsten ball, mounted on the target simulator, is used as the reference point for the planned isocenter. The target simulator is then attached to an adapter mounted on the linac couch, and an EPID image of the simulated target is acquired. The center of the circular-shaped radiation field is calculated from the centroid of the segmented EPID image, and the center of the tungsten ball is identified by an automated computer search algorithm. A summation filter is used to find the position of the lowest radiation intensity coincident with the center of the ball. The alignment error is defined as the difference between the center of the radiation field and the center of the ball. The accuracy of this method was tested and found to be within 0.2 mm. The advantage of the EPID-based procedure is that it can give quantitative offset values quickly for immediate readjustment. We have found that the method is also a convenient tool for testing room laser alignment and the accuracy of the treatment cones.

Entities:  

Mesh:

Year:  1997        PMID: 9048367     DOI: 10.1118/1.598070

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  12 in total

1.  Fast internal marker tracking algorithm for onboard MV and kV imaging systems.

Authors:  W Mao; R D Wiersma; L Xing
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

2.  Development of a QA phantom and automated analysis tool for geometric quality assurance of on-board MV and kV x-ray imaging systems.

Authors:  Weihua Mao; Louis Lee; Lei Xing
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

3.  A fiducial detection algorithm for real-time image guided IMRT based on simultaneous MV and kV imaging.

Authors:  Weihua Mao; Nadeem Riaz; Louis Lee; Rodney Wiersma; Lei Xing
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

4.  A novel method to determine linac mechanical isocenter position and size and examples of specific QA applications.

Authors:  Jacek M Chojnowski; Jonathan R Sykes; David I Thwaites
Journal:  J Appl Clin Med Phys       Date:  2021-05-30       Impact factor: 2.102

5.  Guide to clinical use of electronic portal imaging.

Authors:  M G Herman; J J Kruse; C R Hagness
Journal:  J Appl Clin Med Phys       Date:  2000       Impact factor: 2.102

6.  On the selection of gantry and collimator angles for isocenter localization using Winston-Lutz tests.

Authors:  Weiliang Du; Jennifer L Johnson; Wei Jiang; Rajat J Kudchadker
Journal:  J Appl Clin Med Phys       Date:  2016-01-08       Impact factor: 2.102

7.  Theoretical foundation for real-time prostate localization using an inductively coupled transmitter and a superconducting quantum interference device (SQUID) magnetometer system.

Authors:  John E McGary
Journal:  J Appl Clin Med Phys       Date:  2004-10-01       Impact factor: 2.102

Review 8.  Isocenter verification for linac-based stereotactic radiation therapy: review of principles and techniques.

Authors:  Pejman Rowshanfarzad; Mahsheed Sabet; Daryl J O'Connor; Peter B Greer
Journal:  J Appl Clin Med Phys       Date:  2011-11-15       Impact factor: 2.102

9.  A quality assurance method with submillimeter accuracy for stereotactic linear accelerators.

Authors:  Jimm Grimm; Shu-Ya Lisa Grimm; Indra J Das; Yunping Zhu; Inhwan Yeo; Jinyu Xue; Larry Simpson; Dayee Jacob; Abhirup Sarkar
Journal:  J Appl Clin Med Phys       Date:  2010-12-08       Impact factor: 2.102

10.  Portal dosimetry scripting application programming interface (PDSAPI) for Winston-Lutz test employing ceramic balls.

Authors:  Yao Hao; Matthew C Schmidt; Yu Wu; Nels C Knutson
Journal:  J Appl Clin Med Phys       Date:  2020-10-24       Impact factor: 2.243

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.