Clinically silent microemboli in patients with artificial prosthetic aortic valves are predominantly gaseous and not solid.

M Kaps1, J Hansen, M Weiher, K Tiffert, I Kayser, D W Droste.   

Abstract

BACKGROUND AND
PURPOSE: Microembolic signals (MES) are frequently observed by transcranial Doppler ultrasound after prosthetic heart valve implantation. Whether these MES are due to solid or gaseous particles is uncertain. We hypothesized that MES are gaseous and that if they are due to cavitation effects, their occurrence should respond to changes of dissolved oxygen concentration in the blood.
METHODS: Transcranial monitoring of MES was performed in five patients with prosthetic aortic valves, who inspired 100% oxygen through a facial mask. In one patient 100% oxygen was administered under hyperbaric (2.5 kPa) conditions in a hyperbaric chamber.
RESULTS: Inspiration of 100% oxygen reduced the total number of MES from 96/30 min to 2/30 min. Increasing the concentration of dissolved oxygen in the hyperbaric chamber led to an increase from 0.3 MES per minute (1.0 kPa) to 0.9 MES per minute (2.5 kPa).
CONCLUSIONS: The dependence of occurrence of MES in patients with prosthetic cardiac valves on the oxygen partial pressure in blood provides strong evidence that these microemboli are gaseous.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9040683     DOI: 10.1161/01.str.28.2.322

Source DB:  PubMed          Journal:  Stroke        ISSN: 0039-2499            Impact factor:   7.914


  6 in total

1.  Prevalence of microembolic signals in patients with different types of mono-leaflet and bi-leaflet prosthetic heart valves.

Authors:  M Del Sette; S Angeli; L Badano; M Caudullo; G Bellagamba; R Moccheggiani; C Finocchi; A Focacci; C Gandolfo
Journal:  Ital J Neurol Sci       Date:  1998-10

2.  Oxygen or nitrogen: which is the lesser of two evils?

Authors:  Gary Grist
Journal:  J Extra Corpor Technol       Date:  2013-03

3.  Microembolic Signals Detected by Transcranial Doppler Predict Future Stroke and Poor Outcomes.

Authors:  Alvin S Das; Robert W Regenhardt; Sarah LaRose; Andrew D Monk; Pedro M Castro; Faheem G Sheriff; Farzaneh A Sorond; Henrikas Vaitkevicius
Journal:  J Neuroimaging       Date:  2020-07-10       Impact factor: 2.486

4.  Evaluation of micro-emboli in a patient with ventricular assist device support with hemolysis.

Authors:  Osamu Seguchi; Kozue Saito; Kazuki Fukuma; Keiko Shimamoto; Takuma Sato; Seiko Nakajima; Haruki Sunami; Kensuke Kuroda; Takamasa Sato; Takuya Watanabe; Hiroki Hata; Masanobu Yanase; Tomoyuki Fujita; Junjiro Kobayashi; Kazuyuki Nagatsuka; Takeshi Nakatani
Journal:  J Artif Organs       Date:  2015-03-22       Impact factor: 1.731

5.  Brain Embolism Monitoring with Transcranial Doppler Ultrasound.

Authors:  Viken L. Babikian; Christine A. Wijman
Journal:  Curr Treat Options Cardiovasc Med       Date:  2003-07

6.  Microemboli monitoring by trans-cranial doppler in patient with acute cardioemboliogenic stroke due to atrial myxoma.

Authors:  Gregory Telman; Orit Mesica; Efim Kouperberg; Oved Cohen; Gil Bolotin; Yoram Agmon
Journal:  Neurol Int       Date:  2010-06-21
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.