Screening for glaucomatous visual field loss with frequency-doubling perimetry.

C A Johnson1, S J Samuels.   

Abstract

PURPOSE: To conduct a preliminary evaluation of the efficacy of the frequency-doubling contrast test as a means of screening for glaucomatous visual field loss.
METHODS: Contrast thresholds for frequency-doubled stimuli were obtained under four test conditions: superior hemifield, inferior hemifield, and central (5 degrees radius) targets using a method of adjustment (MOA); superior hemifield, inferior hemifield, and central targets using a modified binary search (MOBS); four quadrant stimuli and the central target using MOBS; and 16 stimuli (four per quadrant) and the central target using MOBS. One eye each of 36 patients with early (12), moderate (12), and advanced (12) glaucomatous visual field loss was tested, as was one eye each of 36 age-matched normal control subjects.
RESULTS: For hemifield stimuli, the MOBS test procedure had better test-retest reliability, lower individual variation, and greater separation of the normal population and the population with glaucoma than did the MOA procedure. The use of progressively smaller, more localized stimuli produced successively better separation of glaucomatous and age-matched normal control eyes. Area under the Receiver Operating Characteristic curve was 0.81 for hemifield stimuli (sensitivity and specificity, 70% to 75%), 0.91 for quadrant stimuli (sensitivity and specificity, 83% to 85%), and 0.965 for the 16 stimuli (sensitivity 93%, specificity 100%). Test time was approximately 1.3 minutes for hemifields, 1.5 minutes for quadrants, and 5 minutes for the 16 targets.
CONCLUSIONS: Preliminary results indicate that the frequency-doubled contrast test provides a quick, efficient means of screening for glaucomatous visual field loss. Test time is relatively short, test-retest reliability is good, and sensitivity and specificity for detection of glaucomatous visual field loss is very good. The use of the MOBS staircase procedure and small, localized stimuli result in the best performance for screening purposes. An expanded normative database and the use of more rapid suprathreshold screening strategies should enhance further the efficacy of this test.

Entities:  

Mesh:

Year:  1997        PMID: 9040475

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  73 in total

1.  Retinal ganglion cell death in experimental glaucoma.

Authors:  J E Morgan; H Uchida; J Caprioli
Journal:  Br J Ophthalmol       Date:  2000-03       Impact factor: 4.638

2.  Clinical comparison of frequency doubling technology perimetry and Humphrey perimetry.

Authors:  R Casson; B James; A Rubinstein; H Ali
Journal:  Br J Ophthalmol       Date:  2001-03       Impact factor: 4.638

3.  African Descent and Glaucoma Evaluation Study (ADAGES): III. Ancestry differences in visual function in healthy eyes.

Authors:  Lyne Racette; Jeffrey M Liebmann; Christopher A Girkin; Linda M Zangwill; Sonia Jain; Lida M Becerra; Felipe A Medeiros; Christopher Bowd; Robert N Weinreb; Catherine Boden; Pamela A Sample
Journal:  Arch Ophthalmol       Date:  2010-05

4.  Correlation between frequency doubling technology perimetry and temporal frequency characteristics in early glaucoma.

Authors:  Joseph Jy-Haw Yu; Motohiro Kiyosawa; Nobuyuki Nemoto; Keiko Momose; Hiroshi Mori; Manabu Mochizuki
Journal:  Doc Ophthalmol       Date:  2003-09       Impact factor: 2.379

5.  Relative hypersensitivity in healthy eye by frequency doubling perimetry in patients with severely damaged contralateral eye.

Authors:  N Fujimoto; D W Zhang; K Minowa; T Hanawa; O Miyauchi; E Adachi-Usami
Journal:  Br J Ophthalmol       Date:  2003-06       Impact factor: 4.638

6.  Psychophysical characterisation of early functional loss in glaucoma and ocular hypertension.

Authors:  E A Ansari; J E Morgan; R J Snowden
Journal:  Br J Ophthalmol       Date:  2002-10       Impact factor: 4.638

7.  Responses of primate retinal ganglion cells to perimetric stimuli.

Authors:  William H Swanson; Hao Sun; Barry B Lee; Dingcai Cao
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-02-09       Impact factor: 4.799

8.  The distribution of visual field defects per quadrant in standard automated perimetry as compared to frequency doubling technology perimetry.

Authors:  Wadih M Zein; Ziad F Bashshur; Rola F Jaafar; Baha' N Noureddin
Journal:  Int Ophthalmol       Date:  2010-10-06       Impact factor: 2.031

9.  Probing glaucoma visual damage by rarebit perimetry.

Authors:  P Brusini; M L Salvetat; L Parisi; M Zeppieri
Journal:  Br J Ophthalmol       Date:  2005-02       Impact factor: 4.638

10.  Predicting progression of glaucoma from rates of frequency doubling technology perimetry change.

Authors:  Daniel Meira-Freitas; Andrew J Tatham; Renato Lisboa; Tung-Mei Kuang; Linda M Zangwill; Robert N Weinreb; Christopher A Girkin; Jeffrey M Liebmann; Felipe A Medeiros
Journal:  Ophthalmology       Date:  2013-11-26       Impact factor: 12.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.