Literature DB >> 9031068

Comparison of the Chiron Quantiplex branched DNA (bDNA) assay and the Abbott Genostics solution hybridization assay for quantification of hepatitis B viral DNA.

G E Kapke1, G Watson, S Sheffler, D Hunt, C Frederick.   

Abstract

Several assays for quantification of DNA have been developed and are currently used in research and clinical laboratories. However, comparison of assay results has been difficult owing to the use of different standards and units of measurements as well as differences between assays in dynamic range and quantification limits. Although a few studies have compared results generated by different assays, there has been no consensus on conversion factors and thorough analysis has been precluded by small sample size and limited dynamic range studied. In this study, we have compared the Chiron branched DNA (bDNA) and Abbott liquid hybridization assays for quantification of hepatitis B virus (HBV) DNA in clinical specimens and have derived conversion factors to facilitate comparison of assay results. Additivity and variance stabilizing (AVAS) regression, a form of non-linear regression analysis, was performed on assay results for specimens from HBV clinical trials. Our results show that there is a strong linear relationship (R2 = 0.96) between log Chiron and log Abbott assay results. Conversion factors derived from regression analyses were found to be non-constant and ranged from 6-40. Analysis of paired assay results below and above each assay's limit of quantification (LOQ) indicated that a significantly (P < 0.01) larger proportion of observations were below the Abbott assay LOQ but above the Chiron assay LOQ, indicating that the Chiron assay is significantly more sensitive than the Abbott assay. Testing of replicate specimens showed that the Chiron assay consistently yielded lower per cent coefficients of variance (% CVs) than the Abbott assay, indicating that the Chiron assay provides superior precision.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9031068     DOI: 10.1046/j.1365-2893.1997.00127.x

Source DB:  PubMed          Journal:  J Viral Hepat        ISSN: 1352-0504            Impact factor:   3.728


  8 in total

1.  A dose ranging study of the pharmacokinetics, safety, and preliminary efficacy of lamivudine in children and adolescents with chronic hepatitis B.

Authors:  E M Sokal; E A Roberts; G Mieli-Vergani; P McPhillips; M Johnson; J Barber; N Dallow; E Boxall; D Kelly
Journal:  Antimicrob Agents Chemother       Date:  2000-03       Impact factor: 5.191

2.  Assessment of the COBAS Amplicor HBV Monitor Test for quantitation of serum hepatitis B virus DNA levels.

Authors:  Vincent A Lopez; Eric J Bourne; Michael W Lutz; Lynn D Condreay
Journal:  J Clin Microbiol       Date:  2002-06       Impact factor: 5.948

Review 3.  Lamivudine. A review of its therapeutic potential in chronic hepatitis B.

Authors:  B Jarvis; D Faulds
Journal:  Drugs       Date:  1999-07       Impact factor: 9.546

4.  Comparison of the second-generation digene hybrid capture assay with the branched-DNA assay for measurement of hepatitis B virus DNA in serum.

Authors:  S K Ho; T M Chan; I K Cheng; K N Lai
Journal:  J Clin Microbiol       Date:  1999-08       Impact factor: 5.948

5.  Two sensitive PCR-based methods for detection of hepatitis B virus variants associated with reduced susceptibility to lamivudine.

Authors:  M I Allen; J Gauthier; M DesLauriers; E J Bourne; K M Carrick; F Baldanti; L L Ross; M W Lutz; L D Condreay
Journal:  J Clin Microbiol       Date:  1999-10       Impact factor: 5.948

6.  Development of a new ultra sensitive real-time PCR assay (ultra sensitive RTQ-PCR) for the quantification of HBV-DNA.

Authors:  Dimitrios Paraskevis; Apostolos Beloukas; Catherine Haida; Antigoni Katsoulidou; Zisis Moschidis; Helen Hatzitheodorou; Agoritsa Varaklioti; Vana Sypsa; Angelos Hatzakis
Journal:  Virol J       Date:  2010-03-12       Impact factor: 4.099

7.  Simultaneous, Single-Cell Measurement of Messenger RNA, Cell Surface Proteins, and Intracellular Proteins.

Authors:  Kah Teong Soh; Joseph D Tario; Sean Colligan; Orla Maguire; Dalin Pan; Hans Minderman; Paul K Wallace
Journal:  Curr Protoc Cytom       Date:  2016-01-06

8.  Fully automated, internally controlled quantification of hepatitis B Virus DNA by real-time PCR by use of the MagNA Pure LC and LightCycler instruments.

Authors:  Victoria Leb; Markus Stöcher; Elizabeth Valentine-Thon; Gabriele Hölzl; Harald Kessler; Herbert Stekel; Jörg Berg
Journal:  J Clin Microbiol       Date:  2004-02       Impact factor: 5.948

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.