Literature DB >> 9015167

Jet-cutting supported by high frequency current: new technique for hepatic surgery.

H G Rau1, E R Buttler, G Baretton, H M Schardey, F W Schildberg.   

Abstract

To reduce blood loss incurred during liver resection, techniques that separate vessels from liver parenchyma, such as the CUSA or the jet-cutter, are in clinical use. By conducting high frequency current through the jet beam using hypertonic NaCl cutting solution, we developed a new method enabling simultaneous coagulation during selective cutting. In this study we examined the effects of this method on liver resection in a rabbit model. With the three techniques-jet-cutting, CUSA, and high frequency-supported jet-cutting (HF-jet)-we performed liver resection of the ventral lobe in six animals per group. We compared velocity of resection, blood loss, tissue trauma, selectivity (number of isolated vessels per area), electrolytes, and vital signs. Histopathology was carried out with the resectate and after 7 days with the remaining liver. Velocity of resection procedure and selectivity were significantly reduced in the HF-jet group. Histopathology showed coagulated vessels and a deeper zone of necrosis. Accordingly, the liver enzymes transiently showed distinctly higher values in the HF-jet group. Electrolyte disturbances or differences of vital signs could not be detected. Transferring our results to patient care we expect that with major resections the hilus clamping time, blood loss, and number of blood transfusions can be reduced. In our opinion the additional application of high frequency through the jet beam is a helpful improvement of the jet-cutter.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9015167     DOI: 10.1007/s002689900225

Source DB:  PubMed          Journal:  World J Surg        ISSN: 0364-2313            Impact factor:   3.352


  10 in total

1.  Two-surgeon technique for hepatic parenchymal transection of the noncirrhotic liver using saline-linked cautery and ultrasonic dissection.

Authors:  Thomas A Aloia; Daria Zorzi; Eddie K Abdalla; Jean-Nicolas Vauthey
Journal:  Ann Surg       Date:  2005-08       Impact factor: 12.969

2.  Clamp-crush technique vs. radiofrequency-assisted liver resection for primary and metastatic liver neoplasms.

Authors:  Spiros Delis; Andreas Bakoyiannis; Nikos Tassopoulos; Kostas Athanassiou; John Papailiou; Elisa N Brountzos; Juan Madariaga; Pavlos Papakostas; Christos Dervenis
Journal:  HPB (Oxford)       Date:  2009-06       Impact factor: 3.647

3.  [Hydrodissection for tonsillectomy. Results of a pilot study--intraoperative blood loss, postoperative pain symptoms and risk of secondary hemorrhage].

Authors:  K J Lorenz; A Kresz; H Maier
Journal:  HNO       Date:  2005-05       Impact factor: 1.284

4.  Hepatic resections using a water-cooled, high-density, monopolar device: a new technology for safer surgery.

Authors:  Isidoro Di Carlo; Francesco Barbagallo; Adriana Toro; Maria Sofia; Tommaso Guastella; Ferdinando Latteri
Journal:  J Gastrointest Surg       Date:  2004 Jul-Aug       Impact factor: 3.452

5.  Hepatic resection in 170 patients using saline-cooled radiofrequency coagulation.

Authors:  David A Geller; Allan Tsung; Vivek Maheshwari; Lisa A Rutstein; John J Fung; J Wallis Marsh
Journal:  HPB (Oxford)       Date:  2005       Impact factor: 3.647

6.  The use of water-jet dissection in open and laparoscopic liver resection.

Authors:  H G Rau; A P Duessel; S Wurzbacher
Journal:  HPB (Oxford)       Date:  2008       Impact factor: 3.647

7.  Tissue damage with different surgical techniques in a porcine model of liver resection: implications for living-donor liver transplantation?

Authors:  Armin Dietmar Goralczyk; Aiman Obed; Angelika Grosse Beilage; Burckhardt Sattler; Laszlo Füzesi; Thomas Lorf
Journal:  J Hepatobiliary Pancreat Sci       Date:  2011-05       Impact factor: 7.027

8.  Interactive decision support in hepatic surgery.

Authors:  Martin Dugas; Rolf Schauer; Andreas Volk; Horst Rau
Journal:  BMC Med Inform Decis Mak       Date:  2002-05-10       Impact factor: 2.796

9.  Efficacy of high-intensity focused ultrasound-assisted hepatic resection (HIFU-AR) on blood loss reduction in patients with liver metastases requiring hepatectomy: study protocol for a randomized controlled trial.

Authors:  Aurélien Dupré; David Pérol; Ellen Blanc; Patrice Peyrat; Valéria Basso; Yao Chen; Jérémy Vincenot; Anthony Kocot; David Melodelima; Michel Rivoire
Journal:  Trials       Date:  2017-02-06       Impact factor: 2.279

10.  Research and development of a new RF-assisted device for bloodless rapid transection of the liver: computational modeling and in vivo experiments.

Authors:  Fernando Burdío; Enrique J Berjano; Ana Navarro; José M Burdío; Luis Grande; Ana Gonzalez; Ignacio Cruz; Antonio Güemes; Ramón Sousa; Jorge Subirá; Tomás Castiella; Ignasi Poves; Juan L Lequerica
Journal:  Biomed Eng Online       Date:  2009-03-18       Impact factor: 2.819

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.