Literature DB >> 9015078

Saccular intracranial aneurysms: endovascular treatment with mechanical detachable spiral coils.

A Tournade1, P Courtheoux, C Sengel, S Ozgulle, T Tajahmady.   

Abstract

PURPOSE: To evaluate endovascular treatment of saccular intracranial aneurysms with mechanical detachable spiral coils.
MATERIALS AND METHODS: Fifty-three patients with 56 saccular aneurysms underwent endovascular treatment with spiral coils. All but five had symptomatic subarachnoid hemorrhage staged according to the Hunt and Hess classification as follows: stage IV or V (n = 20), stage III (n = 10), stage I or II (n = 20), and stage 0 (asymptomatic [n = 6]).
RESULTS: Forty-seven aneurysms were occluded (100% occlusion) on follow-up angiograms with the following time distribution: 24 months for six aneurysms (six patients), 12 months for 14 aneurysms (11 patients), 6 months for 13 aneurysms (13 patients), 4 months for four aneurysms (four patients), and only immediate postprocedure study for 16 aneurysms (16 patients) (excludes two deaths and one failure).
CONCLUSION: In this relatively small group, endovascular treatment with mechanical detachable spiral coils had a success rate of 90%, and it appears to be a rapid, reliable, and relatively safe technique in the treatment of life-threatening subarachnoid hemorrhage.

Entities:  

Mesh:

Year:  1997        PMID: 9015078     DOI: 10.1148/radiology.202.2.9015078

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  8 in total

1.  Retrieval of malpositioned, dislocated or fractured guglielmi detachable coils from intracranial vessels. A report of seven cases.

Authors:  L E Lampmann; M Sluzewski; W J Van Rooij
Journal:  Interv Neuroradiol       Date:  2001-05-15       Impact factor: 1.610

2.  Detachable coil for cerebral aneurysms: in vitro evaluation of magnetic field interactions, heating, and artifacts at 3T.

Authors:  Frank G Shellock; Matthew Gounis; Ajay Wakhloo
Journal:  AJNR Am J Neuroradiol       Date:  2005-02       Impact factor: 3.825

3.  A report of the clinical use of the detach-18 mechanical detachable platinum coil in 41 patients.

Authors:  K J Murph; E Houdart; K T Szopinski; O Levrier; L Guimaraens; D Kühne; L Solymosi; N J Bartholdy; K Sugiu; D A Rüfenacht
Journal:  AJNR Am J Neuroradiol       Date:  2001-02       Impact factor: 3.825

4.  Multiple intracranial aneurysms. Angiographic study and endovascular treatment.

Authors:  F Mont'alverne; A Tournade; C Riquelme; M Musacchio
Journal:  Interv Neuroradiol       Date:  2004-10-20       Impact factor: 1.610

5.  Broad-based intracranial aneurysms: thrombosis induced by stent placement.

Authors:  Ritva Vanninen; Hannu Manninen; Antti Ronkainen
Journal:  AJNR Am J Neuroradiol       Date:  2003-02       Impact factor: 3.825

6.  Endovascular Treatment of Berry Intracranial Aneurysms Using a New Detachable Coil System. (DCS ((R)) - Detachable Coil System Cook).

Authors:  A Tournade; C Riquelme; M Musacchio; F Mont'alverne
Journal:  Interv Neuroradiol       Date:  2001-07-15       Impact factor: 1.610

7.  Follow-up of a Patient Treated by the Mechanical Detachable System (MDS) of Tungsten Spirals. Our Experience.

Authors:  P Kolasa; Z Kaurzel
Journal:  Interv Neuroradiol       Date:  2001-07-15       Impact factor: 1.610

Review 8.  Giant spinal perimedullary fistula in hereditary haemorrhagic telangiectasia: diagnosis, endovascular treatment and review of the literature.

Authors:  F Mont'Alverne; M Musacchio; V Tolentino; F Belzile; C Riquelme; A Tournade
Journal:  Neuroradiology       Date:  2003-10-14       Impact factor: 2.804

  8 in total