Literature DB >> 9004353

TLD extrapolation for skin dose determination in vivo.

T Kron1, M Butson, F Hunt, J Denham.   

Abstract

Prediction of skin reactions requires knowledge of the dose at various depths in the human skin. Using thermoluminescence dosimeters of three different thicknesses, the dose can be extrapolated to the surface and interpolated between the different depths. A TLD holder was designed for these TLD extrapolation measurements on patients during treatment which allowed measurements of entrance and exit skin dose with a day to day variability of +/-7% (S.D. of mean reading). In a pilot study on 18 patients undergoing breast irradiation, it was found that the angle of incidence of the radiation beam is the most significant factor influencing skin entrance dose. In most of these measurements the beam exit dose contributed 50% more to the surface dose than the entrance dose.

Entities:  

Mesh:

Year:  1996        PMID: 9004353     DOI: 10.1016/s0167-8140(96)01795-1

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  6 in total

1.  Dose discrepancies in the buildup region and their impact on dose calculations for IMRT fields.

Authors:  Shu-Hui Hsu; Jean M Moran; Yu Chen; Ravi Kulasekere; Peter L Roberson
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

2.  Superficial dosimetry imaging based on Čerenkov emission for external beam radiotherapy with megavoltage x-ray beam.

Authors:  Rongxiao Zhang; Adam K Glaser; David J Gladstone; Colleen J Fox; Brian W Pogue
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

3.  Development of an applicator for eye lens dosimetry during radiotherapy.

Authors:  J M Park; J Lee; H S Kim; S-J Ye; J-I Kim
Journal:  Br J Radiol       Date:  2014-08-11       Impact factor: 3.039

4.  Superficial dosimetry imaging of Čerenkov emission in electron beam radiotherapy of phantoms.

Authors:  Rongxiao Zhang; Colleen J Fox; Adam K Glaser; David J Gladstone; Brian W Pogue
Journal:  Phys Med Biol       Date:  2013-07-24       Impact factor: 3.609

5.  Beam and tissue factors affecting Cherenkov image intensity for quantitative entrance and exit dosimetry on human tissue.

Authors:  Rongxiao Zhang; Adam K Glaser; Jacqueline Andreozzi; Shudong Jiang; Lesley A Jarvis; David J Gladstone; Brian W Pogue
Journal:  J Biophotonics       Date:  2016-08-10       Impact factor: 3.207

6.  Assessment of Thyroid Lobe Dose in Breast Cancer Intraoperative Radiotherapy.

Authors:  R Ramezani Farkhani; H Gholamhosseinian; K Anvari; M N Forghani
Journal:  J Biomed Phys Eng       Date:  2021-02-01
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.