Literature DB >> 9002826

Bacterial colonization on internal surfaces of Brånemark system implant components.

L G Persson1, U Lekholm, A Leonhardt, G Dahlén, J Lindhe.   

Abstract

The aim of the present study was to examine the microbiota on the internal surface of the components of 28 Brånemark implants in 10 partially edentulous patients who had been treated with 1 fixed partial prostheses each. The prostheses had been in function for 1 to 8 years. The fixed prostheses were checked for mobility and removed. The abutment screws were loosened and classified as stable, easily removed or loose. Then, bacterial samples were obtained from the various internal surfaces of the implant system. Estimation and identification of the most predominant species was performed on the blood agar plates. Identification was based on Gram reaction, oxygen sensitivity and biochemical tests. Internal surfaces of different components of the Brånemark implants, after varying periods of function in the oral cavity, consistently harboured a heterogeneous and primarily anaerobic microbiota. The individual samples showed a great variation. No relation could be seen between type and length of abutment, abutment stability, bone loss and type and number of microorganisms found in the samples. The flora consisted mainly of facultative and anaerobic streptococci, Gram-positive anaerobic rods such as Propionibacterium, Eubacterium and Actinomyces species and Gram-negative anaerobic rods including Fusobacterium, Prevotella and Porphyromonas species. There are reasons to suggest that this presence of bacteria is the result of (i) a contamination of the fixture and abutment components during the 1st and/or 2nd stage of implant installation and/or (ii) a transmission of microorganisms from the oral environment during function subsequent to bridge installation.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 9002826     DOI: 10.1034/j.1600-0501.1996.070201.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  15 in total

1.  Assessment of lipopolysaccharide microleakage at conical implant-abutment connections.

Authors:  Sönke Harder; Elgar Susanne Quabius; Lars Ossenkop; Matthias Kern
Journal:  Clin Oral Investig       Date:  2011-12-02       Impact factor: 3.573

2.  Marginal bony changes in relation to different vertical positions of dental implants.

Authors:  Jung-Myung Yi; Jae-Kwan Lee; Heung-Sik Um; Beom-Seok Chang; Min-Ku Lee
Journal:  J Periodontal Implant Sci       Date:  2010-10-31       Impact factor: 2.614

3.  Resorption of labial bone in maxillary anterior implant.

Authors:  Young-Bum Cho; Seung-Jin Moon; Chae-Heon Chung; Hee-Jung Kim
Journal:  J Adv Prosthodont       Date:  2011-06-30       Impact factor: 1.904

4.  Molecular leakage at implant-abutment connection--in vitro investigation of tightness of internal conical implant-abutment connections against endotoxin penetration.

Authors:  Sönke Harder; Birka Dimaczek; Yaha Açil; Hendrik Terheyden; Sandra Freitag-Wolf; Matthias Kern
Journal:  Clin Oral Investig       Date:  2009-07-23       Impact factor: 3.573

5.  Effect of different localizations of microgap on clinical parameters and inflammatory cytokines in peri-implant crevicular fluid: a prospective comparative study.

Authors:  A Duygu Boynueğri; Mehmet Yalim; Seçil Karakoca Nemli; B Imge Ergüder; Pelin Gökalp
Journal:  Clin Oral Investig       Date:  2011-01-07       Impact factor: 3.573

6.  Ligature-induced peri-implantitis in mice.

Authors:  F Q Pirih; S Hiyari; A D V Barroso; A C A Jorge; J Perussolo; E Atti; S Tetradis; P M Camargo
Journal:  J Periodontal Res       Date:  2014-09-20       Impact factor: 4.419

7.  Development of a new quantitative gas permeability method for dental implant-abutment connection tightness assessment.

Authors:  Jacques-Henri Torres; Michael Mechali; Olivier Romieu; Paul Tramini; Sylvie Callas; Frédéric Jg Cuisinier; Bernard Levallois
Journal:  Biomed Eng Online       Date:  2011-04-14       Impact factor: 2.819

8.  Sealing Capability and SEM Observation of the Implant-Abutment Interface.

Authors:  Fabio C Lorenzoni; Paulo G Coelho; Gerson Bonfante; Ricardo M Carvalho; Nelson R F A Silva; Marcelo Suzuki; Thelma Lopes Silva; Estevam A Bonfante
Journal:  Int J Dent       Date:  2011-07-02

9.  The peri-implant esthetics: An unforgettable entity.

Authors:  Sangeeta Dhir
Journal:  J Indian Soc Periodontol       Date:  2011-04

10.  Influence of the implant-abutment connection design and diameter on the screw joint stability.

Authors:  Hyon-Mo Shin; Jung-Bo Huh; Mi-Jeong Yun; Young-Chan Jeon; Brian Myung Chang; Chang-Mo Jeong
Journal:  J Adv Prosthodont       Date:  2014-04-22       Impact factor: 1.904

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.