Yasmine M Pupo1, Paulo Vitor Farago2, Jessica M Nadal3, Luzia C Simão4, Luís Antônio Esmerino5, Osnara M M Gomes6, João Carlos Gomes7.
Abstract
This study investigated the resin-dentin bond strength (μTBS), degree of conversion (DC), and antibacterial potential of an innovative adhesive system containing a quaternary ammonium methacrylate polymer (QAMP) using in situ and in vitro assays. Forty-two human third molars were flattened until the dentin was exposed and were randomly distributed into three groups of self-etching adhesive systems: Clearfil™ SE Bond containing 5% QAMP (experimental group), Clearfil™ Protect Bond (positive control) and Clearfil™ SE Bond (negative control). After light curing, three 1 mm-increments of composite resin were bonded to each dentin surface. A total of thirty of these bonded teeth (10 teeth per group) was sectioned to obtain stick-shaped specimens and tested under tensile stress immediately, and after 6 and 12 months of storage in distilled water. Twelve bonded teeth (4 teeth per group) were longitudinally sectioned in a mesio-to-distal direction to obtain resin-bonded dentin slabs. In situ DC was evaluated by micro-Raman spectroscopy. In vitro DC of thin films of each adhesive system was measured using Fourier transform infrared spectroscopy. In vitro susceptibility tests of these three adhesive systems were performed by the minimum inhibitory/minimum bactericidal concentration (MIC/MBC) assays against Streptococcus mutans, Lactobacillus casei, and Actinomyces naeslundii. No statistically significant difference in μTBS was observed between Clearfil™ SE Bond containing 5% QAMP and Clearfil™ SE Bond (p>0.05) immediately, and after 6 and 12 months of water storage. However Clearfil™ Protect Bond showed a significant reduction of μTBS after 12 months of storage (p=0.039). In addition, QAMP provided no significant change in DC after incorporating into Clearfil™ SE Bond (p>0.05). Clearfil™ SE Bond containing 5% QAMP demonstrated MIC/MBC values similar to the positive control against L. casei and A. naeslundii and higher than the negative control for all evaluated bacterial strains. The use of QAMP in an adhesive system demonstrated effective bond strength, a suitable degree of conversion, and adequate antibacterial effects against oral bacteria, and may be useful as a new approach to provide long-lasting results for dental adhesives.Entities:
Mesh:
Substances:
Year: 2014 PMID: 24853131 PMCID: PMC4057771 DOI: 10.3390/ijms15058998
Source DB: PubMed Journal: Int J Mol Sci ISSN: 1422-0067 Impact factor: 5.923
Figure 1.Chemical structure of the quaternary ammonium methacrylate polymer (QAMP) [Brazil patent application number 10 2012 0266 4] [28].
Figure 2.Raman spectra of QAMP and raw materials (Eudragit™ E100 and n-octyl bromide). (a1) Raman band at 3030 cm−1 as a broadening of C–H alkyl stretching bands; (a2) A novel band attributed to the symmetric stretching vibration of octyl dimethyl ammonium substituent was verified at 726 cm−1; (b) The C–Br stretching vibration presented in n-octyl bromide between 560 and 650 cm−1 disappeared in QAMP; and (c) Raman bands associated with dimethylamino groups of Eudragit™ E100, previously observed at 2772 and 2821 cm−1 also disappeared.
Mean and standard deviation values of overall resin-dentin bond strength (MPa) from the evaluated adhesive systems.
| Adhesive system | Storage period | ||
|---|---|---|---|
|
| |||
| Immediately | 6 months | 12 months | |
| Clearfil™ SE Bond containing 5% QAMP | 34.88 ± 8.71 Aa | 33.43 ± 5.47 Aa | 32.50 ± 5.94 Aa |
| Clearfil™ Protect Bond | 37.23 ± 6.71 Aa | 39.44 ± 3.25 Aa | 28.20 ± 8.09 Ba |
| Clearfil™ SE Bond | 34.69 ± 5.95 Aa | 32.08 ± 10.97 Aa | 31.27 ± 9.30 Aa |
Groups identified with the same letters are not significantly different (Tukey’s test, p > 0.05), with uppercase letters (for each adhesive system) in rows or lowercase letters (for each storage period) in columns.
Fracture mode and premature debonded specimens from the evaluated adhesive systems (*).
| Adhesive system | Storage period | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| ||||||||||||
| Immediately | 6 months | 12 months | ||||||||||
|
|
|
| ||||||||||
| A/M | C | Debond | T | A/M | C | Debond | T | A/M | C | Debond | T | |
| Clearfil™ SE Bond containing 5% QAMP | 36(80) | 0(0) | 9(20) | 45 | 37(92.5) | 2(5) | 1(2.5) | 40 | 34(94.5) | 0(0) | 2(5.5) | 36 |
| Clearfil™ Protect Bond | 35(79.6) | 0(0) | 9(20.4) | 44 | 35(83.3) | 1(2.4) | 6(14.3) | 42 | 34(91.9) | 1(2.5) | 3(8.1) | 37 |
| Clearfil™ SE Bond | 35(71.4) | 0(0) | 14(28.6) | 49 | 35(81.4) | 0(0) | 8(18.6) | 43 | 35(83.3) | 0(0) | 7(16.7) | 42 |
Results are shown as number, percentage of specimens and total of sticks;
Legend: A/M, adhesive/mixed fracture mode; C, cohesive fracture mode; Debond, premature debonded specimens; T, total.
Figure 3.Micro-Raman spectras of uncured and cured adhesive systems Clearfil™ SE Bond containing 5% QAMP, Clearfil™ Protect Bond, Clearfil™ SE Bond. The reference band is shown at 1609 cm−1 and the reactive band related to C=C group is indicated at 1639 cm−1 (arrows). This band decreases during polymerization and was used for calculating the degree of conversion.
Mean and standard deviation values of in situ analysis of degree of conversion (%) for adhesive systems.
| Adhesive systems | ||
|---|---|---|
| Clearfil™ SE Bond containing 5% QAMP | Clearfil™ Protect Bond | Clearfil™ SE Bond |
| 89 ± 6 a | 85 ± 11 a | 88 ± 3 a |
Groups identified with the same lowercase letters are not significantly different (Tukey’s test, p > 0.05).
Mean and standard deviation values of in vitro analysis of degree of conversion (%) for adhesive systems.
| Adhesive systems | ||
|---|---|---|
| Clearfil™ SE Bond containing 5% QAMP | Clearfil™ Protect Bond | Clearfil™ SE Bond |
| 39.7 ± 2.9 a | 39.8 ± 4.9 a | 40.0 ± 3.0 a |
Same lowercase letters indicate (p > 0.05) in columns.
Minimum inhibitory concentration (MIC) and minimum bactericidal concentration (MBC) values for each adhesive system against three pathogenic oral bacteria.
| Adhesive system | MIC/MBC values (μL/mL) | ||
|---|---|---|---|
|
| |||
| Clearfil™ SE Bond containing 5% QAMP | 20/20 | 10/20 | 20/20 |
| Clearfil™ Protect Bond | 10/10 | 10/20 | 20/20 |
| Clearfil™ SE Bond | 80/80 | 80/>80 | 80/80 |
Adhesive systems: composition (batch number) and application mode.
| Adhesive systems | Composition (batch number) | Application mode |
|---|---|---|
| Clearfil™ SE Bond containing 5% QAMP | Primer: MDP, HEMA, hydrophilic dimethacrylate, | Application of two coats of the primer under pressure (20 s); Gentle air stream (10 s at 20 cm) after application of each coat; Application of one coat of the adhesive (15 s); Gentle air stream to make the bond film uniform (3 s at 20 cm); Light cured (10 s at 600 mW/cm2). |
| Clearfil™ Protect Bond | Primer: MDPB, MDP, HEMA, hydrophilic dimethacrylate, water. (00081B) | |
| Clearfil™ SE Bond | Primer: MDP, HEMA, hydrophilic dimethacrylate, |
Abbreviations: MDP, 10-methacryloxydecyl dihydrogen phosphate; HEMA, 2-hydroxyethyl methacrylate; Bis-GMA, bisphenol-glycidyl methacrylate; MDPB, 12-methacryloyloxydodecyl pyridinium bromide; and QAMP, [poly(dimethylaminoethyl methacrylate-co-octyldimethylammonium ethyl methacrylate bromide-co-methyl methacrylate-co-butyl methacrylate)].