Literature DB >> 8994704

Efficacy of Doppler ultrasonography for assessment of transjugular intrahepatic portosystemic shunt patency.

M Kimura1, M Sato, N Kawai, K Tanaka, T Sonomura, K Kishi, Y Shioyama, M Terada, R Yamada.   

Abstract

PURPOSE: To assess the efficacy of Doppler ultrasonography (US) as a noninvasive method for monitoring patency of the transjugular intrahepatic portosystemic shunt (TIPS).
METHODS: Twenty-nine patients who had received TIPS for bleeding esophagogastric varices and/or refractory ascites with portal hypertension underwent Doppler US studies within 2 weeks after TIPS. Further studies were performed in 15 of them at 6 months, in 9 at 1 year, and in 4 at 2 years for a total of 57 US studies. The US findings were compared with the angiographic findings obtained at the same time.
RESULTS: In 45 of the 57 studies, shunt patency was found by Doppler US, correlating to 44 patencies and one occlusion on angiography. Doppler signal in the shunt could not be detected in 12 studies resulting in the diagnosis of shunt occlusion. This correlated with angiographic occlusion in 8 studies and patency in the remaining 4. All angiographically patent shunts that were occluded by Doppler US had various degrees of stenosis. A number of technical factors were found to be responsible for Doppler US false-positive or false-negative diagnoses, some related to the type of stent used. The Doppler US sensitivity was therefore 92%, the specificity 89%.
CONCLUSION: Doppler US is a reliable noninvasive method to evaluate patency of TIPS.

Entities:  

Mesh:

Year:  1996        PMID: 8994704     DOI: 10.1007/bf02577626

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  17 in total

1.  [Nonsurgical production of intrahepatic portosystemic venous shunts in portal hypertension with the double lumen balloon catheter (author's transl)].

Authors:  F A Burgener; O H Gutierrez
Journal:  Rofo       Date:  1979-06

2.  Color Doppler imaging of portosystemic shunts.

Authors:  E G Grant; F N Tessler; A S Gomes; C L Holmes; R R Perrella; A J Duerinckx; R W Busuttil
Journal:  AJR Am J Roentgenol       Date:  1990-02       Impact factor: 3.959

3.  Experimental intrahepatic portacaval anastomosis: use of expandable Gianturco stents.

Authors:  J Rösch; B T Uchida; J S Putnam; R W Buschman; R D Law; A L Hershey
Journal:  Radiology       Date:  1987-02       Impact factor: 11.105

4.  Transjugular portal venography and radiologic portacaval shunt: an experimental study.

Authors:  J Rösch; W N Hanafee; H Snow
Journal:  Radiology       Date:  1969-04       Impact factor: 11.105

5.  Transjugular intrahepatic portosystemic shunt: US assessment with maximum flow velocity.

Authors:  W K Chong; T A Malisch; M J Mazer; C D Lind; J A Worrell; W O Richards
Journal:  Radiology       Date:  1993-12       Impact factor: 11.105

6.  Formation of intrahepatic portosystemic shunts using a balloon dilatation catheter: preliminary clinical experience.

Authors:  R F Colapinto; R D Stronell; M Gildiner; A C Ritchie; B Langer; B R Taylor; L M Blendis
Journal:  AJR Am J Roentgenol       Date:  1983-04       Impact factor: 3.959

7.  Creation of an intrahepatic portosystemic shunt with a Grüntzig balloon catheter.

Authors:  R F Colapinto; R D Stronell; S J Birch; B Langer; L M Blendis; P D Greig; T Gilas
Journal:  Can Med Assoc J       Date:  1982-02-01       Impact factor: 8.262

8.  Color Doppler sonography of transjugular intrahepatic portosystemic shunts (TIPS).

Authors:  M C Foshager; H Ferral; D E Finlay; W R Castañeda-Zúñiga; J G Letourneau
Journal:  AJR Am J Roentgenol       Date:  1994-07       Impact factor: 3.959

9.  Early sonographic evaluation of the transjugular intrahepatic portosystemic shunt (TIPS).

Authors:  H Ferral; M C Foshager; H Bjarnason; D E Finlay; D W Hunter; W R Castañeda-Zúñiga; J G Letourneau
Journal:  Cardiovasc Intervent Radiol       Date:  1993 Sep-Oct       Impact factor: 2.740

10.  [The transjugular intrahepatic portosystemic stent-shunt. A new nonsurgical percutaneous method].

Authors:  G M Richter; J C Palmaz; G Nöldge; M Rössle; V Siegerstetter; M Franke; W Wenz
Journal:  Radiologe       Date:  1989-08       Impact factor: 0.635

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.