Literature DB >> 8269422

Early sonographic evaluation of the transjugular intrahepatic portosystemic shunt (TIPS).

H Ferral1, M C Foshager, H Bjarnason, D E Finlay, D W Hunter, W R Castañeda-Zúñiga, J G Letourneau.   

Abstract

The purpose of this study was to evaluate duplex and color Doppler findings in patients before and within 24 h after transjugular intrahepatic portosystemic shunts (TIPS). Conventional duplex and color Doppler were used in the assessment of 19 patients who underwent TIPS as part of a prospective protocol. Patients were examined within 24 h before and after the procedure. Before TIPS, patency, flow direction, and peak flow velocity in the main portal vein and hepatic artery were studied, as well as patency and flow direction in hepatic veins, splenic vein, and inferior vena cava (IVC). Immediately after the procedure, sonographic identification of stent position, shunt patency, and flow dynamics were evaluated and patency and flow direction of hepatic veins, splenic vein, and IVC were determined. The portogram performed at the end of the procedure was compared with the 24-h sonographic studies after TIPS to determine sonographic/angiographic correlation. No intraparenchymal abnormalities or perihepatic fluid collections were detected after the procedure. The metallic stent was clearly seen in all patients. Mean peak shunt flow velocities were 139 +/- 50 cm/sec within 24 h after TIPS. Absence of flow through the shunt was correctly identified in one case and confirmed angiographically. Mean peak flow velocity in the portal vein before TIPS was 22 +/- 13.6 cm/sec and increased to 43.6 +/- 9.1 cm/sec after TIPS (p < 0.05). The hepatic artery peak systolic velocity increased from 77 +/- 51 cm/sec before TIPS to 119 +/- 53 cm/sec after the procedure (p = 0.029).(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1993        PMID: 8269422     DOI: 10.1007/bf02629157

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  16 in total

1.  Hemodynamics during liver transplantation: the interactions between cardiac output and portal venous and hepatic arterial flows.

Authors:  J M Henderson; G T Gilmore; G J Mackay; J R Galloway; T F Dodson; M H Kutner
Journal:  Hepatology       Date:  1992-09       Impact factor: 17.425

2.  Color Doppler imaging of portosystemic shunts.

Authors:  E G Grant; F N Tessler; A S Gomes; C L Holmes; R R Perrella; A J Duerinckx; R W Busuttil
Journal:  AJR Am J Roentgenol       Date:  1990-02       Impact factor: 3.959

3.  Technical advances in transjugular intrahepatic portosystemic shunts.

Authors:  G Zemel; G J Becker; J W Bancroft; J F Benenati; B T Katzen
Journal:  Radiographics       Date:  1992-07       Impact factor: 5.333

4.  Early hemodynamic changes following selective distal splenorenal shunt for portal hypertension: comparison of surgical techniques.

Authors:  G P Spina; R Santambrogio; E Opocher; F Gattoni; U Baldini; G Cucchiaro; C Uslenghi; G Pezzuoli
Journal:  World J Surg       Date:  1990 Jan-Feb       Impact factor: 3.352

Review 5.  Hemodynamic considerations in evaluation of arterial disease by Doppler ultrasound.

Authors:  R E Zierler
Journal:  Clin Diagn Ultrasound       Date:  1990

6.  Duplex scanning of the portal vein and portasystemic shunts.

Authors:  N Ackroyd; R Gill; K Griffiths; G Kossoff; T Reeve
Journal:  Surgery       Date:  1986-05       Impact factor: 3.982

7.  Duplex ultrasound in the evaluation of portacaval shunts.

Authors:  J P Finn; R N Gibson; G D Dunn
Journal:  Clin Radiol       Date:  1987-01       Impact factor: 2.350

Review 8.  Mechanism and role of intrinsic regulation of hepatic arterial blood flow: hepatic arterial buffer response.

Authors:  W W Lautt
Journal:  Am J Physiol       Date:  1985-11

9.  Duplex Doppler examination in portal hypertension: technique and anatomy.

Authors:  H Patriquin; M Lafortune; P N Burns; M Dauzat
Journal:  AJR Am J Roentgenol       Date:  1987-07       Impact factor: 3.959

10.  Transjugular intrahepatic portacaval stent shunt: preliminary clinical results.

Authors:  G M Richter; G Noeldge; J C Palmaz; M Roessle; V Slegerstetter; M Franke; W Gerok; W Wenz; E Farthman
Journal:  Radiology       Date:  1990-03       Impact factor: 11.105

View more
  2 in total

1.  Scintigraphic evaluation of hepatic blood flow after intrahepatic portosystemic shunt (TIPS).

Authors:  J Menzel; O Schober; P Reimer; W Domschke
Journal:  Eur J Nucl Med       Date:  1997-06

2.  Efficacy of Doppler ultrasonography for assessment of transjugular intrahepatic portosystemic shunt patency.

Authors:  M Kimura; M Sato; N Kawai; K Tanaka; T Sonomura; K Kishi; Y Shioyama; M Terada; R Yamada
Journal:  Cardiovasc Intervent Radiol       Date:  1996 Nov-Dec       Impact factor: 2.740

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.