Phase-modulated binomial RF pulses for fast spectrally-selective musculoskeletal imaging.

D Thomasson1, D Purdy, J P Finn.   

Abstract

Two fat-suppressed three-dimensional gradient echo pulse sequences, FLASH and DESS (Double Echo in Steady-State), that have significantly reduced scan time compared with conventional chemical shift fat-suppression sequences are presented. This fat-suppression technique is based on selectively exciting water spins using a time-optimized binomial RF pulse pair at the water resonance frequency with a null in the excitation profile at the fat frequency. To minimize the total pulse length, the delay between the binomial components of the RF pulse is decreased from a standard jump-return implementation. To maintain the proper null frequency, the phase of the second RF pulse is shifted such that it returns the fat resonance back to its initial z position while further tipping the water spins. Nonselective phase-modulated RF pulse pairs can be implemented in 1.20 ms at 1.0 T, significantly reducing the minimum TR.

Entities:  

Mesh:

Year:  1996        PMID: 8992207     DOI: 10.1002/mrm.1910350416

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  8 in total

1.  Optimized spectrally selective steady-state free precession sequences for cartilage imaging at ultra-high fields.

Authors:  O Bieri; T C Mamisch; S Trattnig; O Kraff; M E Ladd; K Scheffler
Journal:  MAGMA       Date:  2007-11-21       Impact factor: 2.310

2.  Sequence design and evaluation of the reproducibility of water-selective diffusion-weighted imaging of the breast at 3 T.

Authors:  He Zhu; Lori R Arlinghaus; Jennifer G Whisenant; Ming Li; John C Gore; Thomas E Yankeelov
Journal:  NMR Biomed       Date:  2014-07-01       Impact factor: 4.044

3.  Parallel excitation for B-field insensitive fat-saturation preparation.

Authors:  Jeremiah A Heilman; Jamal D Derakhshan; Matthew J Riffe; Natalia Gudino; Jean Tkach; Chris A Flask; Jeffrey L Duerk; Mark A Griswold
Journal:  Magn Reson Med       Date:  2012-01-13       Impact factor: 4.668

4.  Water excitation: a possible pitfall in cerebral time-of-flight angiography.

Authors:  Elke R Gizewski; Mark E Ladd; Andrena Paul; Isabel Wanke; Sophie Göricke; Michael Forsting
Journal:  AJNR Am J Neuroradiol       Date:  2005-01       Impact factor: 3.825

5.  Subchondral bone and cartilage thickness from MRI: effects of chemical-shift artifact.

Authors:  Chris A McGibbon; Jenny Bencardino; William E Palmer
Journal:  MAGMA       Date:  2003-02       Impact factor: 2.310

6.  Quadrupolar jump-and-return pulse sequence for fluid-suppressed sodium MRI of the knee joint at 7T.

Authors:  Ding Xia; Jae-Seung Lee; Ravinder R Regatte
Journal:  Magn Reson Med       Date:  2017-12-19       Impact factor: 4.668

7.  Rapid phase-modulated water excitation steady-state free precession for fat suppressed cine cardiovascular MR.

Authors:  Hung-Yu Lin; Subha V Raman; Yiu-Cho Chung; Orlando P Simonetti
Journal:  J Cardiovasc Magn Reson       Date:  2008-05-13       Impact factor: 5.364

8.  Correcting time-intensity curves in dynamic contrast-enhanced breast MRI for inhomogeneous excitation fields at 7T.

Authors:  Michael J van Rijssel; Josien P W Pluim; Hui-Shan M Chan; Lieke van den Wildenberg; Alexander M Th Schmitz; Peter R Luijten; Kenneth G A Gilhuijs; Dennis W J Klomp
Journal:  Magn Reson Med       Date:  2019-12-27       Impact factor: 4.668

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.