Literature DB >> 8989750

Glomerular filtration rate determined from a single plasma sample after intravenous iohexol injection: is it reliable?

F Gaspari1, E Guerini, N Perico, L Mosconi, P Ruggenenti, G Remuzzi.   

Abstract

The iohexol injection plasma clearance method is a good alternative to the inulin clearance method for determination of GFR, but requires multiple blood samples. To avoid this, methods have been developed which derive GFR from a formula that uses a single plasma concentration of the tracer and anthropometric data. The aim of this study was to evaluate whether a single plasma sample taken after iohexol injection allows reliable estimation of GFR. In this study, results of single-point determination were compared with those obtained by multiple-point plasma clearance. The GFR of 686 outpatients with different degrees of renal function were recalculated by use of the Jacobsson formula. The optimum time for sampling was found at 10 h after injection of the marker for clearances < 40 mL/min per 1.73 m2, 4 h for clearances between 40 and 99 mL/min per 1.73 m2, and 3 h for clearances > 100 mL/min per 1.73 m2. Results documented that for 75% of the patients, the simplified technique gave an error between -5% to +5% in the evaluation of GFR; for the remaining 25% of the patients, prediction error ranged from -22% to +40%. Furthermore, despite a highly significant correlation between multiple-point iohexol clearance (six plasma samples) and the single-point method (Y = 0.968X + 1.704, r2 = 0.988), the regression intercept was statistically different from 0 and the standard error of the slope estimate established that 95% confidence interval did not include 1.0 (the line of identity), thus indicating that the model can be rejected by the data at a significance level of 0.05. Thus the single-plasma-sample method to determine GFR after radiocontrast injection does not represent a real advantage over the multiple-point method and may lead to unacceptable errors in GFR calculation.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8989750     DOI: 10.1681/ASN.V7122689

Source DB:  PubMed          Journal:  J Am Soc Nephrol        ISSN: 1046-6673            Impact factor:   10.121


  12 in total

1.  Glomerular filtration rate (GFR) estimated from serum creatinine predicts total (urine and peritoneal) creatinine clearance in patients on peritoneal dialysis.

Authors:  Hulya Taskapan; Pliakogiannis Theodoros; Paul Tam; Joanne Bargman; Dimitrios Oreopoulos
Journal:  Int Urol Nephrol       Date:  2010-04-04       Impact factor: 2.370

2.  Optimizing iohexol plasma disappearance curves to measure the glomerular filtration rate in children with chronic kidney disease.

Authors:  George J Schwartz; Alison G Abraham; Susan L Furth; Bradley A Warady; Alvaro Muñoz
Journal:  Kidney Int       Date:  2010-01       Impact factor: 10.612

3.  An efficient approach for glomerular filtration rate assessment in older adults.

Authors:  Peter Martus; Natalie Ebert; Markus van der Giet; Olga Jakob; Elke S Schaeffner
Journal:  Br J Clin Pharmacol       Date:  2014-08       Impact factor: 4.335

4.  Reply to 'Strengths and limitations of estimated and measured GFR'.

Authors:  Esteban Porrini; Piero Ruggenenti; Sergio Luis-Lima; Fabiola Carrara; Alejandro Jiménez; Aiko P J de Vries; Armando Torres; Flavio Gaspari; Giuseppe Remuzzi
Journal:  Nat Rev Nephrol       Date:  2019-12       Impact factor: 28.314

5.  Iohexol plasma clearance for measuring glomerular filtration rate: effect of different ways to calculate the area under the curve.

Authors:  Hans Pottel; Elke Schaeffner; Natalie Ebert; Markus van der Giet; Pierre Delanaye
Journal:  BMC Nephrol       Date:  2021-05-05       Impact factor: 2.388

6.  Measurement of glomerular filtration rate by rapid intravenous injection of a newly developed inulin fraction.

Authors:  Yoshitaka Maeda; Yuya Araki; Tomomi Uno; Akiko Yoshida; Keisuke Nishigaki; Naoto Inaba; Hiroaki Hayashi; Yoshiharu Deguchi
Journal:  J Rural Med       Date:  2011

7.  Iohexol clearance for determination of glomerular filtration rate in rats induced to acute renal failure.

Authors:  Michelle T Passos; Sonia K Nishida; Niels O S Câmara; Maria Heloisa Shimizu; Gianna Mastroianni-Kirsztajn
Journal:  PLoS One       Date:  2015-04-13       Impact factor: 3.240

8.  Iohexol plasma clearance in children: validation of multiple formulas and single-point sampling times.

Authors:  Camilla Tøndel; Cathrin Lytomt Salvador; Karl Ove Hufthammer; Bjørn Bolann; Damien Brackman; Anna Bjerre; Einar Svarstad; Atle Brun
Journal:  Pediatr Nephrol       Date:  2017-11-13       Impact factor: 3.714

9.  Iohexol plasma clearance for measuring glomerular filtration rate in clinical practice and research: a review. Part 1: How to measure glomerular filtration rate with iohexol?

Authors:  Pierre Delanaye; Natalie Ebert; Toralf Melsom; Flavio Gaspari; Christophe Mariat; Etienne Cavalier; Jonas Björk; Anders Christensson; Ulf Nyman; Esteban Porrini; Giuseppe Remuzzi; Piero Ruggenenti; Elke Schaeffner; Inga Soveri; Gunnar Sterner; Bjørn Odvar Eriksen; Sten-Erik Bäck
Journal:  Clin Kidney J       Date:  2016-08-23

10.  Iohexol plasma clearance in children: validation of multiple formulas and two-point sampling times.

Authors:  Camilla Tøndel; Bjørn Bolann; Cathrin Lytomt Salvador; Damien Brackman; Anna Bjerre; Einar Svarstad; Atle Brun
Journal:  Pediatr Nephrol       Date:  2016-07-01       Impact factor: 3.714

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.