Literature DB >> 8988200

Simulation of subtle lung nodules in projection chest radiography.

E Samei1, M J Flynn, W R Eyler.   

Abstract

PURPOSE: To measure the radiologic characteristics of subtle lung nodules and develop nodule phantoms that simulate these characteristics.
MATERIALS AND METHODS: From a database of chest radiographs, 16 radiographs that showed confirmed subtle lung nodules were selected. The optical density values surrounding each nodule were obtained, and the radiologic characteristic of the nodules were evaluated. A set of Teflon nodule phantoms with similar x-ray transmission and variability was designed and fabricated. The contrast characteristics of the images of the nodule phantoms were measured.
RESULTS: Most of the subtle nodules appeared to have diffuse edges with Gaussian-like contrast profiles. The contrast and size characteristics of the nodule phantom images fulfilled the design criteria within a 4% deviation.
CONCLUSION: The radiologic pattern of subtle lung nodules is poorly simulated by nodule phantoms with simple spherical or disk shapes. The nodule phantoms in this study produce realistic radiographic patterns with an energy-dependent attenuation equivalent to that of tissue. The nodule phantoms are intended for use in experiments involving human subjects.

Entities:  

Mesh:

Year:  1997        PMID: 8988200     DOI: 10.1148/radiology.202.1.8988200

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  13 in total

1.  Task-based assessment of breast tomosynthesis: effect of acquisition parameters and quantum noise.

Authors:  I Reiser; R M Nishikawa
Journal:  Med Phys       Date:  2010-04       Impact factor: 4.071

2.  Single-exposure dual-energy subtraction chest radiography: detection of pulmonary nodules and masses in clinical practice.

Authors:  Zsolt Szucs-Farkas; Michael A Patak; Seyran Yuksel-Hatz; Thomas Ruder; Peter Vock
Journal:  Eur Radiol       Date:  2007-09-27       Impact factor: 5.315

3.  Grey-scale inversion improves detection of lung nodules.

Authors:  J W Robinson; J T Ryan; M F McEntee; S J Lewis; M G Evanoff; L A Rainford; P C Brennan
Journal:  Br J Radiol       Date:  2012-05-09       Impact factor: 3.039

4.  Effects of automatic tube potential selection on radiation dose index, image quality, and lesion detectability in pediatric abdominopelvic CT and CTA: a phantom study.

Authors:  Michael F Brinkley; Juan C Ramirez-Giraldo; Ehsan Samei; Daniel J Frush; Kingshuk Roy Choudhury; Joshua M Wilson; Olav I Christianson; Donald P Frush
Journal:  Eur Radiol       Date:  2015-05-20       Impact factor: 5.315

5.  Local complexity metrics to quantify the effect of anatomical noise on detectability of lung nodules in chest CT imaging.

Authors:  Taylor Brunton Smith; Geoffrey D Rubin; Justin Solomon; Brian Harrawood; Kingshuk Roy Choudhury; Ehsan Samei
Journal:  J Med Imaging (Bellingham)       Date:  2018-11-22

6.  Grey-scale inversion improves detection of lung nodules.

Authors:  J W Robinson; J T Ryan; M F McEntee; S J Lewis; M G Evanoff; L A Rainford; P C Brennan
Journal:  Br J Radiol       Date:  2013-01       Impact factor: 3.039

7.  Biplane correlation imaging: a feasibility study based on phantom and human data.

Authors:  Ehsan Samei; Nariman Majdi-Nasab; James T Dobbins; H Page McAdams
Journal:  J Digit Imaging       Date:  2012-02       Impact factor: 4.056

8.  Interchangeability between real and three-dimensional simulated lung tumors in computed tomography: an interalgorithm volumetry study.

Authors:  Marthony Robins; Justin Solomon; Jocelyn Hoye; Taylor Smith; Yuese Zheng; Lukas Ebner; Kingshuk Roy Choudhury; Ehsan Samei
Journal:  J Med Imaging (Bellingham)       Date:  2018-09-24

9.  The effect of averaging adjacent planes for artifact reduction in matrix inversion tomosynthesis.

Authors:  Devon J Godfrey; H Page McAdams; James T Dobbins
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

10.  An alternate method for using a visual discrimination model (VDM) to optimize soft-copy display image quality.

Authors:  Dev P Chakraborty
Journal:  J Soc Inf Disp       Date:  2006-10       Impact factor: 2.140

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.