Literature DB >> 8987267

An automatic technique for finding and localizing externally attached markers in CT and MR volume images of the head.

M Y Wang1, C R Maurer, J M Fitzpatrick, R J Maciunas.   

Abstract

An image processing technique is presented for finding and localizing the centroids of cylindrical markers externally attached to the human head in computed tomography (CT) and magnetic resonance (MR) image volumes. The centroids can be used as control points for image registration. The technique, which is fast, automatic, and knowledge-based, has two major steps. First, it searches the entire image volume to find one voxel inside each marker-like object. We call this voxel a "candidate" voxel, and we call the object a candidate marker. Second, it classifies the voxels in a region surrounding the candidate voxel as marker or nonmarker voxels using knowledge-based rules and calculates an intensity-weighted centroid for each true marker. We call this final centroid the "fiducial" point of the marker. The technique was developed on 42 scans of six patients-one CT and six MR scans per patient. There are four markers attached to each patient for a total of 168 marker images. For the CT images the false marker rate was zero. For MR the false marker rate was 1.4% (Two out of 144 markers). To evaluate the accuracy of the fiducial points, CT-MR registration was performed after correcting the MR images for geometrical distortion. The fiducial registration accuracy averaged 0.4 mm and was better than 0.6 mm for each of the eighteen image pairs.

Entities:  

Mesh:

Year:  1996        PMID: 8987267     DOI: 10.1109/10.495282

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  22 in total

Review 1.  The role of image-guided technology in the surgical planning and resection of gliomas.

Authors:  G H Barnett
Journal:  J Neurooncol       Date:  1999-05       Impact factor: 4.130

Review 2.  Computer-aided navigation in neurosurgery.

Authors:  P Grunert; K Darabi; J Espinosa; R Filippi
Journal:  Neurosurg Rev       Date:  2003-05       Impact factor: 3.042

3.  An imaging co-registration system using novel non-invasive and non-radioactive external markers.

Authors:  Tung-Hsin Wu; Jiunn-Kuen Wang; Jason J S Lee; Ren-Shyan Liu; Wan-Yuo Guo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-04-12       Impact factor: 9.236

4.  Marker-free registration for the accurate integration of CT images and the subject's anatomy during navigation surgery of the maxillary sinus.

Authors:  S-H Kang; M-K Kim; J-H Kim; H-K Park; W Park
Journal:  Dentomaxillofac Radiol       Date:  2012-04-12       Impact factor: 2.419

5.  Strategy for accurate liver intervention by an optical tracking system.

Authors:  Qinyong Lin; Rongqian Yang; Ken Cai; Peifeng Guan; Weihu Xiao; Xiaoming Wu
Journal:  Biomed Opt Express       Date:  2015-08-07       Impact factor: 3.732

6.  New technique for real-time interface pressure analysis: getting more out of large image data sets.

Authors:  Kath Bogie; Xiaofeng Wang; Baowei Fei; Jiayang Sun
Journal:  J Rehabil Res Dev       Date:  2008

Review 7.  Surgical planning tool for robotically assisted hearing aid implantation.

Authors:  Nicolas Gerber; Brett Bell; Kate Gavaghan; Christian Weisstanner; Marco Caversaccio; Stefan Weber
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-06-14       Impact factor: 2.924

8.  Cadaveric Testing of Robot-Assisted Access to the Internal Auditory Canal for Vestibular Schwannoma Removal.

Authors:  Neal P Dillon; Ramya Balachandran; Michael A Siebold; Robert J Webster; George B Wanna; Robert F Labadie
Journal:  Otol Neurotol       Date:  2017-03       Impact factor: 2.311

9.  Minimally invasive image-guided cochlear implantation for pediatric patients: clinical feasibility study.

Authors:  Ramya Balachandran; Fitsum A Reda; Jack H Noble; Grégoire S Blachon; Benoit M Dawant; J Michael Fitzpatrick; Robert F Labadie
Journal:  Otolaryngol Head Neck Surg       Date:  2014-01-21       Impact factor: 3.497

10.  Accuracy and reproducibility of tumor positioning during prolonged and multi-modality animal imaging studies.

Authors:  Mutian Zhang; Minming Huang; Carl Le; Pat B Zanzonico; Filip Claus; Katherine S Kolbert; Kyle Martin; C Clifton Ling; Jason A Koutcher; John L Humm
Journal:  Phys Med Biol       Date:  2008-09-30       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.