Literature DB >> 8974863

Volumetric capillary cytometry: a new method for absolute cell enumeration.

L J Dietz1, R S Dubrow, B S Manian, N L Sizto.   

Abstract

This article describes a novel cytometry system that is capable of imaging, identifying, and counting populations of fluorescently labeled cells within a precisely known volume of unlysed whole blood contained in a precision capillary. The whole blood is reacted with dye-labeled antibodies directed at cell surface antigens. A red excitation source (helium-neon laser) is used to minimize auto-fluorescence and interference by blood components. A two-color fluorescence detection system is described, using the dyes Cy5 and Cy5.5, allowing the simultaneous detection and quantitation of two different types of surface antigens. Image processing techniques are used to identify cellular events in the image and to quantitate the fluorescent intensities in both color planes. The utility of this technique is demonstrated by performing absolute CD3+/CD4+ lymphocyte counts in whole blood, with minimal sample preparation, and with the blood sample completely contained in a disposable cartridge. A correlation study comparing this technique to flow cytometry gives a correlation coefficient of 0.98. In addition, the ability of this system to monitor reaction kinetics is demonstrated with a measurement of the rate of association of the anti-CD4 antibody onto the surface of CD4+ lymphocytes.

Entities:  

Mesh:

Year:  1996        PMID: 8974863     DOI: 10.1002/(SICI)1097-0320(19960301)23:3<177::AID-CYTO1>3.0.CO;2-G

Source DB:  PubMed          Journal:  Cytometry        ISSN: 0196-4763


  8 in total

1.  Ligand-receptor binding measured by laser-scanning imaging.

Authors:  P Zuck; Z Lao; S Skwish; J F Glickman; K Yang; J Burbaum; J Inglese
Journal:  Proc Natl Acad Sci U S A       Date:  1999-09-28       Impact factor: 11.205

2.  Development of a frozen cell array as a high-throughput approach for cell-based analysis.

Authors:  Jean Philippe Stephan; Silvia Schanz; Anne Wong; Peter Schow; Wai Lee T Wong
Journal:  Am J Pathol       Date:  2002-09       Impact factor: 4.307

3.  Evaluation of a new single-parameter volumetric flow cytometer (CyFlow(green)) for enumeration of absolute CD4+ T lymphocytes in human immunodeficiency virus type 1-infected Thai patients.

Authors:  Kovit Pattanapanyasat; Surada Lerdwana; Egarit Noulsri; Thanyanan Chaowanachan; Punneeporn Wasinrapee; Natthaga Sakulploy; Vallerut Pobkeeree; Orapin Suksripanich; Sombat Thanprasertsuk; Thomas J Spira; Jordan W Tappero; William C Levine
Journal:  Clin Diagn Lab Immunol       Date:  2005-12

4.  Inter- and intrainstitutional evaluation of automated volumetric capillary cytometry for the quantitation of CD4- and CD8-positive T lymphocytes in the peripheral blood of persons infected with human immunodeficiency virus. Site Investigators and the NIAID New CD4 Technologies Focus Group.

Authors:  M R O'Gorman; R Gelman
Journal:  Clin Diagn Lab Immunol       Date:  1997-03

5.  An immunomagnetic single-platform image cytometer for cell enumeration based on antibody specificity.

Authors:  Xiao Li; Arjan G J Tibbe; Erik Droog; Leon W M M Terstappen; Jan Greve
Journal:  Clin Vaccine Immunol       Date:  2007-02-07

6.  Deconvoluting post-transplant immunity: cell subset-specific mapping reveals pathways for activation and expansion of memory T, monocytes and B cells.

Authors:  Yevgeniy A Grigoryev; Sunil M Kurian; Zafi Avnur; Dominic Borie; Jun Deng; Daniel Campbell; Joanna Sung; Tania Nikolcheva; Anthony Quinn; Howard Schulman; Stanford L Peng; Randolph Schaffer; Jonathan Fisher; Tony Mondala; Steven Head; Stuart M Flechner; Aaron B Kantor; Christopher Marsh; Daniel R Salomon
Journal:  PLoS One       Date:  2010-10-14       Impact factor: 3.240

7.  In search of cellular immunophenotypes in the blood of children with autism.

Authors:  Paul Ashwood; Blythe A Corbett; Aaron Kantor; Howard Schulman; Judy Van de Water; David G Amaral
Journal:  PLoS One       Date:  2011-05-04       Impact factor: 3.240

Review 8.  Portraying G protein-coupled receptors with fluorescent ligands.

Authors:  Francisco Ciruela; Kenneth A Jacobson; Víctor Fernández-Dueñas
Journal:  ACS Chem Biol       Date:  2014-07-28       Impact factor: 5.100

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.