Abstract

UNLABELLED: High-resolution pinhole-SPECT (PSPECT) is a new method for examining the thyroid gland.
METHODS: The camera is tilted slightly so that it is as close to the thyroid as possible. Patients are injected with 185-260 MBq (5-7 mCi) of [99mTc]pertechnetate and examined for 20 min. The reconstruction algorithm is based on filtered back-projection.
RESULTS: We performed static scintigraphy on the thyroids of 114 patients, followed by PSPECT. The major advantage of P SPECT is high resolution. Three- and 4-mm-pinholes produce resolutions of 6 mm and 7 mm, respectively, while resolutions obtained with a parallel collimator are always above 15 mm. The second advantage associated with this method is the good visualization of the cold nodules surrounded by higher activity. Finally, the reconstruction program provides exact sizes of thyroids.
CONCLUSION: SPECT is a powerful tool for examining the thyroid.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8970526

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  8 in total

Review 1.  The pinhole: gateway to ultra-high-resolution three-dimensional radionuclide imaging.

Authors:  Freek Beekman; Frans van der Have
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-02       Impact factor: 9.236

2.  Will high-resolution/high-sensitivity SPECT ensure that PET is not the only survivor in nuclear medicine during the next decade?

Authors:  Alain Seret
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-01-14       Impact factor: 9.236

3.  Analytic Determination of Rectangular-Pinhole Sensitivity With Penetration.

Authors:  Scott D Metzler; Stephen C Moore
Journal:  IEEE Trans Med Imaging       Date:  2019-08-19       Impact factor: 10.048

Review 4.  Use of tomographic nuclear medicine procedures, SPECT and pinhole SPECT, with cationic lipophilic radiotracers for the evaluation of axillary lymph node status in breast cancer patients.

Authors:  Giuseppe Madeddu; Angela Spanu
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-04-15       Impact factor: 9.236

5.  99mTc-MIBI pinhole SPECT in primary hyperparathyroidism: comparison with conventional SPECT, planar scintigraphy and ultrasonography.

Authors:  Thomas Carlier; Aurore Oudoux; Eric Mirallié; Alain Seret; Isabelle Daumy; Christophe Leux; Caroline Bodet-Milin; Françoise Kraeber-Bodéré; Catherine Ansquer
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-10-25       Impact factor: 9.236

6.  Body contour 180 degrees pinhole SPET with or without tilted detector: a phantom study.

Authors:  Alain Seret; David Flérès; Olivier Firket; Michel Defrise
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-06-17       Impact factor: 9.236

Review 7.  Advances in pinhole and multi-pinhole collimators for single photon emission computed tomography imaging.

Authors:  Jalil Pirayesh Islamian; AhmadReza Azazrm; Babak Mahmoudian; Esmail Gharapapagh
Journal:  World J Nucl Med       Date:  2015 Jan-Apr

8.  Quantitative capabilities of four state-of-the-art SPECT-CT cameras.

Authors:  Alain Seret; Daniel Nguyen; Claire Bernard
Journal:  EJNMMI Res       Date:  2012-08-27       Impact factor: 3.138

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.