Literature DB >> 8960620

Measuring cardiac output in critically Ill patients: disagreement between thermodilution-, calculated-, expired gas-, and oxygen consumption-based methods.

M S Sherman1, R Kosinski, H L Paz, D Campbell.   

Abstract

Calculated values of oxygen consumption have been used to calculate a Fick cardiac output when thermodilution measurements are unreliable and when oxygen consumption measurements are unavailable. To determine the accuracy of these calculations, we measured cardiac output in 20 patients by four methods: (1) a reference Fick cardiac output calculated from metabolic oxygen consumption measurements and arterial-venous oxygen content difference (COmet); (2) thermodilution cardiac output (COtherm), (3) an estimated Fick cardiac output based on calculated oxygen consumption using standard equations (COcalc), and (4) an estimated Fick cardiac output using a bedside measurement of expired carbon dioxide production (COexp). The mean difference +/- 95% limits of agreement between COtherm and COmet was 1.71 +/- 5 liters/min. The mean difference between COcalc and COmet was -0.04 +/- 3.33 liters/min. The mean difference between COexp and COmet was 0.31 +/- 3.01 liters/min. On the basis of these wide confidence intervals, we conclude that (1) thermodilution and metabolic measurements of cardiac output frequently differ in critically ill patients, and (2) estimates of oxygen consumption, based on either standard equations or on expired carbon dioxide production measurements, are poor substitutes for metabolic measurements of oxygen consumption in critically ill subjects and may provide inaccurate estimates of cardiac output.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 8960620     DOI: 10.1159/000177304

Source DB:  PubMed          Journal:  Cardiology        ISSN: 0008-6312            Impact factor:   1.869


  10 in total

1.  What's in a beat?

Authors:  Mervyn Singer
Journal:  Intensive Care Med       Date:  2003-10       Impact factor: 17.440

Review 2.  [Measurement of cardiac output].

Authors:  D A Reuter; A E Goetz
Journal:  Anaesthesist       Date:  2005-11       Impact factor: 1.041

Review 3.  Cardiac output in 1998.

Authors:  M Singer
Journal:  Heart       Date:  1998-05       Impact factor: 5.994

4.  Validation of a new method based on ultrasound velocity dilution to measure cardiac output in paediatric patients.

Authors:  Alejandro A Floh; Gustavo La Rotta; Julius Z Wermelt; Patricia Bastero-Miñón; V Ben Sivarajan; Tilman Humpl
Journal:  Intensive Care Med       Date:  2013-02-22       Impact factor: 17.440

5.  Stroke volume equation for impedance cardiography.

Authors:  D P Bernstein; H J M Lemmens
Journal:  Med Biol Eng Comput       Date:  2005-07       Impact factor: 2.602

6.  Cardiac Output Assessment in Patients Supported with Left Ventricular Assist Device: Discordance Between Thermodilution and Indirect Fick Cardiac Output Measurements.

Authors:  David M Tehrani; Jonathan Grinstein; Sara Kalantari; Gene Kim; Nitasha Sarswat; Sirtaz Adatya; Gabriel Sayer; Nir Uriel
Journal:  ASAIO J       Date:  2017 Jul/Aug       Impact factor: 2.872

7.  Measured versus predicted oxygen consumption in children with congenital heart disease.

Authors:  P O Laitinen; J Räsänen
Journal:  Heart       Date:  1998-12       Impact factor: 5.994

8.  Differences of cardiac output measurements by open-circuit acetylene uptake in pulmonary arterial hypertension and chronic thromboembolic pulmonary hypertension: a cohort study.

Authors:  Martin Schwaiblmair; Christian Faul; Wolfgang von Scheidt; Thomas M Berghaus
Journal:  Respir Res       Date:  2012-03-12

9.  Quantification of Cardiac Output with Phase Contrast Magnetic Resonance Imaging in Patients with Pulmonary Hypertension.

Authors:  Jose Ricardo Po; Matthew Tong; Talha Meeran; Alekhya Potluri; Amresh Raina; Mark Doyle; Robert Biederman
Journal:  J Clin Imaging Sci       Date:  2020-05-02

10.  Comparison of bedside measurement of cardiac output with the thermodilution method and the Fick method in mechanically ventilated patients.

Authors:  Jésus Gonzalez; Christian Delafosse; Muriel Fartoukh; André Capderou; Christian Straus; Marc Zelter; Jean-Philippe Derenne; Thomas Similowski
Journal:  Crit Care       Date:  2002-12-20       Impact factor: 9.097

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.