Literature DB >> 8956643

Long-term fluctuation of relative afferent pupillary defect in subjects with normal visual function.

A Kawasaki1, P Moore, R H Kardon.   

Abstract

PURPOSE: To determine whether the relative afferent pupillary defect (RAPD) remains constant over time in normal subjects.
METHODS: Seventeen normal subjects were tested with infrared pupillography and automated perimetry in four sessions over 3 years. The changes in RAPD and visual field asymmetry between testing sessions were compared.
RESULTS: The range of RAPD was 0.0 to 0.3 log unit, and the difference in the mean deviation between the eyes on automated static perimetry was 0 to 3 dB. Eight subjects repeatedly had an RAPD in the same eye. There was no correlation between the RAPD and the visual field asymmetry at the same visit. Changes in the magnitude of the RAPD between any two sessions were typically small (median, 0.08 log unit; 25th percentile, 0.04 log unit; 75th percentile, 0.15 log unit).
CONCLUSIONS: Some normal subjects may show a persistent but small RAPD in the absence of detectable pathologic disease. Therefore, an isolated RAPD in the range of 0.3 log unit that is not associated with any other significant historical or clinical finding should probably be considered benign.

Entities:  

Mesh:

Year:  1996        PMID: 8956643     DOI: 10.1016/s0002-9394(14)70385-x

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  9 in total

1.  Quantification of retinal nerve fiber layer thickness reduction associated with a relative afferent pupillary defect in asymmetric glaucoma.

Authors:  Yasuko Tatsumi; Makoto Nakamura; Miyuki Fujioka; Yoriko Nakanishi; Azusa Kusuhara; Hidetaka Maeda; Akira Negi
Journal:  Br J Ophthalmol       Date:  2006-10-18       Impact factor: 4.638

2.  The effects of tolterodine on anterior segment and choroidal thickness in patients with overactive bladder syndrome.

Authors:  Hande Hüsniye Telek; Omer Gokhan Doluoglu; Ayse Burcu; Gulizar Demirok; Firdevs Ornek; Ali Ayyildiz
Journal:  Ther Adv Urol       Date:  2017-04-11

3.  Evaluation of Relative Afferent Pupillary Defect Using RAPDx Device in Patients with Optic Nerve Disease.

Authors:  Tsukasa Satou; Hitoshi Ishikawa; Ken Asakawa; Toshiaki Goseki; Takahiro Niida; Kimiya Shimizu
Journal:  Neuroophthalmology       Date:  2016-04-14

4.  The usefulness of a new method of testing for a relative afferent pupillary defect in patients with ocular hypertension and glaucoma.

Authors:  Dara Lankaranian; Undraa Altangerel; George L Spaeth; Jacqueline A Leavitt; William C Steinmann
Journal:  Trans Am Ophthalmol Soc       Date:  2005

Review 5.  The investigation of acute optic neuritis: a review and proposed protocol.

Authors:  Axel Petzold; Mike P Wattjes; Fiona Costello; Jose Flores-Rivera; Clare L Fraser; Kazuo Fujihara; Jacqueline Leavitt; Romain Marignier; Friedemann Paul; Sven Schippling; Christian Sindic; Pablo Villoslada; Brian Weinshenker; Gordon T Plant
Journal:  Nat Rev Neurol       Date:  2014-07-08       Impact factor: 42.937

6.  Relative afferent pupillary defect with normal vision and vertical strabismus--implications for pupillary pathway anatomy.

Authors:  Flemming Staubach; Christina Pieh; Philip Maier; Wolf A Lagrèze
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2007-02       Impact factor: 3.117

7.  Pupillography of automated swinging flashlight test in amblyopia.

Authors:  Atsushi Miki; Atsuhiko Iijima; Mineo Takagi; Kiyoshi Yaoeda; Tomoaki Usui; Shigeru Hasegawa; Haruki Abe; Takehiko Bando
Journal:  Clin Ophthalmol       Date:  2008-12

8.  Effects of Age and Sex on Values Obtained by RAPDx® Pupillometer, and Determined the Standard Values for Detecting Relative Afferent Pupillary Defect.

Authors:  Tsukasa Satou; Toshiaki Goseki; Ken Asakawa; Hitoshi Ishikawa; Kimiya Shimizu
Journal:  Transl Vis Sci Technol       Date:  2016-04-28       Impact factor: 3.283

9.  Relative Afferent Pupillary Defects in Homonymous Visual Field Defects Caused by Stroke of the Occipital Lobe Using Pupillometer.

Authors:  Go Takizawa; Atsushi Miki; Fumiatsu Maeda; Katsutoshi Goto; Syunsuke Araki; Tsutomu Yamashita; Yoshiaki Ieki; Junichi Kiryu; Kiyoshi Yaoeda
Journal:  Neuroophthalmology       Date:  2017-08-31
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.