Motion and image artifacts of various intracranial aneurysm clips in a magnetic field.

K Ooka1, M Shibuya, Y Suzuki.   

Abstract

Deflection angles of 36 types of Sugita intracranial aneurysm clips (Elgiloy), 2 types of Yasargil clips (Phynox), a Kirschner chip (SUS316) and a silver clip were examined by suspending each in a 1.5-tesla MRI (TOSHIBA MRT-200/FXII). Image artifacts of 5 types of intracranial aneurysm clips were also studied quantitatively with respect to their ratio of artifact/actual clip size using a spin-echo sequence with T1-weighted (Time of repetition (TR) = 500 ms, Time of echo (TE) = 20 ms) and T2-weighted (TR = 2000 ms, TE = 80 ms) images. All the Sugita clips from mini type to long type showed a deflection angle of less than 1.0 degree, the Yasargil clips less than 2.0 degrees, the Kirschner chip less than 6.0 degrees, and the silver chip did not move at all. Both brands of clips are therefore suitable for intracranial applications. The artifact size was directly proportional to the clip size and weight, though the ratio of artifact/actual width tended to decrease proportionately as the actual size and weight increased. The ratio of the width seemed slightly bigger than that of the length, but the difference did not reach statistical significance. There was no significant difference in the ratio of image artifacts/clip size between T1- and T2-weighted images.

Entities:  

Mesh:

Year:  1996        PMID: 8955445     DOI: 10.1007/bf01809754

Source DB:  PubMed          Journal:  Acta Neurochir (Wien)        ISSN: 0001-6268            Impact factor:   2.216


  14 in total

1.  Magnetic resonance imaging and aneurysm clips. Magnetic properties and image artifacts.

Authors:  B Romner; M Olsson; B Ljunggren; S Holtås; H Säveland; L Brandt; B Persson
Journal:  J Neurosurg       Date:  1989-03       Impact factor: 5.115

2.  Magnetic field effects on surgical ligation clips.

Authors:  M A Brown; J A Carden; R E Coleman; R McKinney; L D Spicer
Journal:  Magn Reson Imaging       Date:  1987       Impact factor: 2.546

3.  Artifacts in MR imaging after surgical intervention.

Authors:  W Heindel; G Friedmann; J Bunke; B Thomas; R Firsching; R I Ernestus
Journal:  J Comput Assist Tomogr       Date:  1986 Jul-Aug       Impact factor: 1.826

4.  The effects of magnetic resonance imaging on different types of microsurgical clips.

Authors:  D M Kean; B S Worthington; J L Firth; R C Hawkes
Journal:  J Neurol Neurosurg Psychiatry       Date:  1985-03       Impact factor: 10.154

5.  Potential hazards in NMR imaging: heating effects of changing magnetic fields and RF fields on small metallic implants.

Authors:  P L Davis; L Crooks; M Arakawa; R McRee; L Kaufman; A R Margulis
Journal:  AJR Am J Roentgenol       Date:  1981-10       Impact factor: 3.959

6.  Ferromagnetic materials in patients: detection before MR imaging.

Authors:  E J Finn; G Di Chiro; R A Brooks; S Sato
Journal:  Radiology       Date:  1985-07       Impact factor: 11.105

7.  High-field-strength MR imaging and metallic biomedical implants: an ex vivo evaluation of deflection forces.

Authors:  F G Shellock; J V Crues
Journal:  AJR Am J Roentgenol       Date:  1988-08       Impact factor: 3.959

8.  Placement of a ferromagnetic intracerebral aneurysm clip in a magnetic field with a fatal outcome.

Authors:  R P Klucznik; D A Carrier; R Pyka; R W Haid
Journal:  Radiology       Date:  1993-06       Impact factor: 11.105

9.  Potential hazards and artifacts of ferromagnetic and nonferromagnetic surgical and dental materials and devices in nuclear magnetic resonance imaging.

Authors:  P F New; B R Rosen; T J Brady; F S Buonanno; J P Kistler; C T Burt; W S Hinshaw; J H Newhouse; G M Pohost; J M Taveras
Journal:  Radiology       Date:  1983-04       Impact factor: 11.105

10.  MR imaging in patients with intracranial aneurysm clips.

Authors:  R L Becker; J F Norfray; G P Teitelbaum; W G Bradley; J B Jacobs; L Wacaser; R L Rieman
Journal:  AJNR Am J Neuroradiol       Date:  1988-09       Impact factor: 3.825

View more
  1 in total

1.  Artifact quantification and tractography from 3T MRI after placement of aneurysm clips in subarachnoid hemorrhage patients.

Authors:  Faraz Khursheed; Fiona Rohlffs; Shuichi Suzuki; Dong H Kim; Timothy M Ellmore
Journal:  BMC Med Imaging       Date:  2011-10-04       Impact factor: 1.930

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.