Dynamic coherence analysis of vasomotion and flow motion in skeletal muscle microcirculation.

S Bertuglia1, A Colantuoni, M Arnold, H Witte.   

Abstract

The aim of our study was to determine the cause of fluctuations in microvascular blood flow measured by laser Doppler perfusion monitoring (LDPM) in microvessels of the hamster skin fold preparation. LDPM flow fluctuations (flow motion) were compared to simultaneous records of diameter changes obtained from arterioles and venules. Time-varying coherence analysis was used to quantify the frequency of flow and diameter changes in awake hamsters in control conditions and during sodium nitroprusside-induced vasodilation. Power spectrum analysis of LDPM signals of order 4 and 3 arterioles indicated frequencies of 0.06 +/- 0.01 and 0.08 +/- 0.02 Hz, respectively. Order 3 arterioles exhibited significant temporal coherence between flow motion and vasomotion signals at a frequency of the order of 0.1 Hz. There was lack of coherence when vasomotion was absent in arterioles. Order 4 arterioles had several coherent frequencies in addition to that around 0.1 Hz. In conclusion, time-variant coherence analysis indicated that spontaneous fluctuations in flow are caused by vasomotion of order 3 arterioles with frequency around 0.1 Hz that appears to coordinate local control processes in the microcirculation. Additional frequency components present in LDPM signals are unrelated to vasomotion.

Entities:  

Mesh:

Year:  1996        PMID: 8954865     DOI: 10.1006/mvre.1996.0061

Source DB:  PubMed          Journal:  Microvasc Res        ISSN: 0026-2862            Impact factor:   3.514


  8 in total

1.  Maximum shortening velocity of lymphatic muscle approaches that of striated muscle.

Authors:  Rongzhen Zhang; Anne I Taucer; Anatoliy A Gashev; Mariappan Muthuchamy; David C Zawieja; Michael J Davis
Journal:  Am J Physiol Heart Circ Physiol       Date:  2013-08-30       Impact factor: 4.733

2.  Spontaneous oscillations in a model for active control of microvessel diameters.

Authors:  J C Arciero; T W Secomb
Journal:  Math Med Biol       Date:  2011-04-27       Impact factor: 1.854

3.  Wavelet analysis of lumbar muscle oxygenation signals during whole-body vibration: implications for the development of localized muscle fatigue.

Authors:  Zengyong Li; Ming Zhang; Guoqiang Chen; Site Luo; Feifei Liu; Jianping Li
Journal:  Eur J Appl Physiol       Date:  2012-01-01       Impact factor: 3.078

4.  Stochasticity of flow through microcirculation as a regulator of oxygen delivery.

Authors:  Viktor V Kislukhin
Journal:  Theor Biol Med Model       Date:  2010-07-09       Impact factor: 2.432

5.  Changes of Blood Flux at BL21 and Points along BL Meridian Resulted from Acupuncture or Moxibustion: Case Cross Design Study.

Authors:  Guangjun Wang; Shuyong Jia; Hongyan Li; Ze Wang; Yuying Tian; Weibo Zhang
Journal:  Evid Based Complement Alternat Med       Date:  2017-07-24       Impact factor: 2.629

6.  Response of Blood Perfusion at ST 36 Acupoint after Drinking Cold Glucose or Saline Injection.

Authors:  Guangjun Wang; Shuyong Jia; Hongyan Li; Ze Wang; Yuying Tian; Weibo Zhang
Journal:  Evid Based Complement Alternat Med       Date:  2017-03-30       Impact factor: 2.629

7.  Physiological Mechanisms Mediating the Coupling between Heart Period and Arterial Pressure in Response to Postural Changes in Humans.

Authors:  Alessandro Silvani; Giovanna Calandra-Buonaura; Blair D Johnson; Noud van Helmond; Giorgio Barletta; Anna G Cecere; Michael J Joyner; Pietro Cortelli
Journal:  Front Physiol       Date:  2017-03-27       Impact factor: 4.566

8.  Pilot study of blood perfusion coherence along the meridian in forearm.

Authors:  Guangjun Wang; Yuying Tian; Shuyong Jia; Wenting Zhou; Weibo Zhang
Journal:  BMC Complement Altern Med       Date:  2013-11-23       Impact factor: 3.659

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.