Literature DB >> 8947907

A CT assisted method for absolute quantitation of internal radioactivity.

A Liu1, L E Williams, A A Raubitschek.   

Abstract

A method is described for the determination of radioactivity (microCi or MBq) at an organ site within an object or patient. Using both anatomic image data (CT or MRI scans) and planar gamma camera images, activity at depth is determined using a matrix inversion method based on least squares. The result of the inversion analysis was the unknown set of n linear (uniform) activity densities representative of each organ within the phantom or patient. The problem was overdetermined since the number of unknown activity densities (microCi/cm) was much less than the number of analysis points (N) within the nuclear image. This method, defined as the CT assisted matrix inversion (CAMI) technique, was accurate to within 15% for a three "organ" plastic phantom, wherein the organs were right circular cylinders having activities of 74 to 508 microCi (or 2.74 MBq to 18.8 MBq). This accuracy included image quantitation effects, particularly assumptions concerning attenuation correction. The average absolute percent error of the estimated activity in four distinct radioactive volumes in the phantom was 9.8%. It was found that the background activity within the phantom was estimated to be too high if sampling regions near strong sources were used in the analysis (scatter effect). This was minimized by going at least 2 cm away from such sources. By applying the method to a monoclonal antibody clinical study, activities within the patient's major organs such as liver, spleen, and kidney could be estimated, even in cases where the organ could not be visualized. Here, the CAMI algorithm gave internally consistent results for the patient's left and right lung linear activity concentrations. The CAMI technique resolves the problem of tissue superimposition using depth information from 3-D CT and is applicable in cases where a number of organs overlap in the gamma camera image. Thus, the method should be generally useful to nuclear image quantitation and the estimation of absorbed radiation doses in patients. One particular application is the estimation of radiation doses in radioimmunotherapy (RIT).

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8947907     DOI: 10.1118/1.597755

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  EQPlanar: a maximum-likelihood method for accurate organ activity estimation from whole body planar projections.

Authors:  N Song; B He; R L Wahl; E C Frey
Journal:  Phys Med Biol       Date:  2011-08-03       Impact factor: 3.609

Review 2.  Technological development and advances in single-photon emission computed tomography/computed tomography.

Authors:  Youngho Seo; Carina Mari; Bruce H Hasegawa
Journal:  Semin Nucl Med       Date:  2008-05       Impact factor: 4.446

3.  Activity quantification combining conjugate-view planar scintigraphies and SPECT/CT data for patient-specific 3-D dosimetry in radionuclide therapy.

Authors:  Yannick Berker; Andreas Goedicke; Gerrit J Kemerink; Til Aach; Bernd Schweizer
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-09-08       Impact factor: 9.236

4.  The effect of volume-of-interest misregistration on quantitative planar activity and dose estimation.

Authors:  N Song; B He; E C Frey
Journal:  Phys Med Biol       Date:  2010-08-27       Impact factor: 3.609

5.  Phase I biodistribution and pharmacokinetic study of Lewis Y-targeting immunoconjugate CMD-193 in patients with advanced epithelial cancers.

Authors:  Rebecca A Herbertson; Niall C Tebbutt; Fook-Thean Lee; David J MacFarlane; Bridget Chappell; Noel Micallef; Sze-Ting Lee; Timothy Saunder; Wendie Hopkins; Fiona E Smyth; David K Wyld; John Bellen; Daryl S Sonnichsen; Martin W Brechbiel; Carmel Murone; Andrew M Scott
Journal:  Clin Cancer Res       Date:  2009-10-13       Impact factor: 12.531

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.