Literature DB >> 8946346

Visualization of dedicated catheters using fast scanning techniques with potential for MR-guided vascular interventions.

C J Bakker1, R M Hoogeveen, J Weber, J J van Vaals, M A Viergever, W P Mali.   

Abstract

This paper reports the development of dedicated catheters and real-time MR scan techniques for guiding vascular interventional procedures. By way of phantom experiments, it is shown that proper modification of the magnetic properties of catheters allows their conspicuous and consistent visualization in subsecond 2D gradient echo images and phase contrast angiograms. Dynamic scan times as low as 0.5 s could be achieved by exploiting the keyhole technique and purposeful postprocessing. The temporal resolution and spatial resolution of the resultant scan protocol shows promise for adequate tracking of catheter manipulation.

Mesh:

Substances:

Year:  1996        PMID: 8946346     DOI: 10.1002/mrm.1910360603

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  21 in total

1.  A brief review of hardware for catheter tracking in magnetic resonance imaging.

Authors:  Jeffrey L Duerk; Eddy Y Wong; Jonathan S Lewin
Journal:  MAGMA       Date:  2002-01       Impact factor: 2.310

Review 2.  Cardiovascular interventional magnetic resonance imaging.

Authors:  Robert J Lederman
Journal:  Circulation       Date:  2005-11-08       Impact factor: 29.690

3.  Real-time magnetic resonance imaging to guide pediatric endovascular procedures.

Authors:  A N Raval; R J Lederman
Journal:  Pediatr Cardiol       Date:  2005 May-Jun       Impact factor: 1.655

Review 4.  Stem cell therapy: MRI guidance and monitoring.

Authors:  Dara L Kraitchman; Wesley D Gilson; Christine H Lorenz
Journal:  J Magn Reson Imaging       Date:  2008-02       Impact factor: 4.813

Review 5.  MR-guided endovascular interventions: a comprehensive review on techniques and applications.

Authors:  Sebastian Kos; Rolf Huegli; Georg M Bongartz; Augustinus L Jacob; Deniz Bilecen
Journal:  Eur Radiol       Date:  2007-12-11       Impact factor: 5.315

6.  Control of intravascular catheters using an array of active steering coils.

Authors:  N Gudino; J A Heilman; J J Derakhshan; J L Sunshine; J L Duerk; M A Griswold
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

7.  Using a low-amplitude RF pulse at echo time (LARFET) for device localization in MRI.

Authors:  Murat Tümer; Baykal Sarioglu; Senol Mutlu; Yekta Ulgen; Arda Yalcinkaya; Cengizhan Ozturk
Journal:  Med Biol Eng Comput       Date:  2014-08-31       Impact factor: 2.602

Review 8.  Interventional cardiovascular magnetic resonance imaging: a new opportunity for image-guided interventions.

Authors:  Christina E Saikus; Robert J Lederman
Journal:  JACC Cardiovasc Imaging       Date:  2009-11

9.  Active two-channel 0.035'' guidewire for interventional cardiovascular MRI.

Authors:  Ozgur Kocaturk; Ann H Kim; Christina E Saikus; Michael A Guttman; Anthony Z Faranesh; Cengizhan Ozturk; Robert J Lederman
Journal:  J Magn Reson Imaging       Date:  2009-08       Impact factor: 4.813

10.  Whole shaft visibility and mechanical performance for active MR catheters using copper-nitinol braided polymer tubes.

Authors:  Ozgur Kocaturk; Christina E Saikus; Michael A Guttman; Anthony Z Faranesh; Kanishka Ratnayaka; Cengizhan Ozturk; Elliot R McVeigh; Robert J Lederman
Journal:  J Cardiovasc Magn Reson       Date:  2009-08-12       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.