Literature DB >> 8945665

Endpoint error in smoothing and differentiating raw kinematic data: an evaluation of four popular methods.

P F Vint1, R N Hinrichs.   

Abstract

'Endpoint error' describes the erratic behavior at the beginning and end of the computed acceleration data which is commonly observed after smoothing and differentiating raw displacement data. To evaluate endpoint error produced by four popular smoothing and differentiating techniques, Lanshammar's (1982, J. Biomechanics 15, 99-105) modification of the Pezzack et al. (1977, J. Biomechanics, 10, 377-382) raw angular displacement data set was truncated at three different locations corresponding to the major peaks in the criterion acceleration curve. Also, for each data subset, three padding conditions were applied. Each data subset was smoothed and differentiated using the Butterworth digital filter, cubic spline, quintic spline, and Fourier series to obtain acceleration values. RMS residual errors were calculated between the computed and criterion accelerations in the endpoint regions. Although no method completely eliminated endpoint error, the results demonstrated clear superiority of the quintic spline over the other three methods in producing accurate acceleration values close to the endpoints of the modified Pezzack et al. (1977) data set. In fact, the quintic spline performed best with non-padded data (cumulative error = 48.0 rad s-2). Conversely, when applied to non-padded data, the Butterworth digital filter produced wildly deviating values beginning more than the 10 points from the terminal data point (cumulative error = 226.6 rad s-2). Each of the four methods performed better when applied to data subsets padded by linear extrapolation (average cumulative error = 68.8 rad s-2) than when applied to analogous subsets padded by reflection (average cumulative error = 86.1 rad s-2).

Entities:  

Mesh:

Year:  1996        PMID: 8945665

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  7 in total

1.  Real-time Kalman filter applied to biomechanical data for state estimation and numerical differentiation.

Authors:  A M Sabatini
Journal:  Med Biol Eng Comput       Date:  2003-01       Impact factor: 2.602

2.  Time course of the effect of the Muller-Lyer illusion on saccades and perceptual judgments.

Authors:  Anouk J de Brouwer; Eli Brenner; W Pieter Medendorp; Jeroen B J Smeets
Journal:  J Vis       Date:  2014-01-06       Impact factor: 2.240

3.  When does a gait transition occur during human locomotion?

Authors:  Alan Hreljac; Rodney T Imamura; Rafael F Escamilla; W Brent Edwards
Journal:  J Sports Sci Med       Date:  2007-03-01       Impact factor: 2.988

4.  Reliability of Three-Dimensional Linear Kinematics and Kinetics of Swimming Derived from Digitized Video at 25 and 50 Hz with 10 and 5 Frame Extensions to the 4(th) Order Butterworth Smoothing Window.

Authors:  Ross H Sanders; Tomohiro Gonjo; Carla B McCabe
Journal:  J Sports Sci Med       Date:  2015-05-08       Impact factor: 2.988

5.  Reliability of Three-Dimensional Angular Kinematics and Kinetics of Swimming Derived from Digitized Video.

Authors:  Ross H Sanders; Tomohiro Gonjo; Carla B McCabe
Journal:  J Sports Sci Med       Date:  2016-02-23       Impact factor: 2.988

6.  Local interactions underlying collective motion in human crowds.

Authors:  Kevin W Rio; Gregory C Dachner; William H Warren
Journal:  Proc Biol Sci       Date:  2018-05-16       Impact factor: 5.349

7.  Follow the leader: visual control of speed in pedestrian following.

Authors:  Kevin W Rio; Christopher K Rhea; William H Warren
Journal:  J Vis       Date:  2014-02-07       Impact factor: 2.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.