Literature DB >> 8939236

Effect of the rate of gadopentetate dimeglumine administration on abdominal vascular and soft-tissue MR imaging enhancement patterns.

P J Strouse1, M R Prince, T L Chenevert.   

Abstract

PURPOSE: To delineate dynamic gadopentetate dimeglumine enhancement profiles within the abdomen as a guide to improve gadolinium-enhanced magnetic resonance (MR) angiography.
MATERIALS AND METHODS: Fifteen patients (eight women, seven men; aged 19-80 years) underwent fast three-dimensional spoiled gradient-recalled-echo imaging with the keyhole technique during the administration of 0.1 mmol/kg gadopentetate dimeglumine by means of bolus (10-second) injection (n = 5), 60 second injection (n = 5), or slow (120-230-second) pump injection (n = 5). Injection was initiated 10 seconds after imaging began. Regions of interest were constructed within the aorta, inferior vena cava, liver, spleen, renal cortex, muscle, and fat. Inclusion of phantoms of gadopentetate dimeglumine in tubes allowed estimation of intravascular gadolinium concentration.
RESULTS: Maximal arterial enhancement occurred with bolus administration; maximal parenchymal organ enhancement, with 60-second injection. Slow pump injection resulted in a longer time to preferential arterial to venous enhancement (120 seconds +/- 14 [+/-standard deviation]) than did bolus (48 seconds +/- 64) or 60-second (88 seconds +/- 39) injections. The peak arterial to venous enhancement ratio was 6.3 +/- 3.3 for the bolus injection, 4.7 +/- 1.6 for the 60-second injection, and 3.3 +/- 1.3 for the slow pump injection.
CONCLUSION: The dynamics and magnitude of abdominal vascular and soft-tissue enhancement are affected by the rate of gadopentetate dimeglumine administration.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8939236     DOI: 10.1148/radiology.201.3.8939236

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  5 in total

1.  Contrast-enhanced magnetic resonance angiography: dose the test dose bolus represent the main dose bolus accurately?

Authors:  J J Lee; Y Chang; D S Kang
Journal:  Korean J Radiol       Date:  2000 Apr-Jun       Impact factor: 3.500

2.  Evaluation of the intracranial dural sinuses with a 3D contrast-enhanced MP-RAGE sequence: prospective comparison with 2D-TOF MR venography and digital subtraction angiography.

Authors:  L Liang; Y Korogi; T Sugahara; M Onomichi; Y Shigematsu; D Yang; M Kitajima; Y Hiai; M Takahashi
Journal:  AJNR Am J Neuroradiol       Date:  2001-03       Impact factor: 3.825

3.  Circumventricular organs of human brain visualized on post-contrast 3D fluid-attenuated inversion recovery imaging.

Authors:  Minako Azuma; Toshinori Hirai; Yoshihito Kadota; Zaw Aung Khant; Yohei Hattori; Mika Kitajima; Hiroyuki Uetani; Yasuyuki Yamashita
Journal:  Neuroradiology       Date:  2018-05-02       Impact factor: 2.804

4.  Comparison of post-contrast 3D-T1-MPRAGE, 3D-T1-SPACE and 3D-T2-FLAIR MR images in evaluation of meningeal abnormalities at 3-T MRI.

Authors:  Balaji Jeevanandham; Tejas Kalyanpur; Prashant Gupta; Mathew Cherian
Journal:  Br J Radiol       Date:  2017-04-26       Impact factor: 3.039

5.  Comparison of the added value of contrast-enhanced 3D fluid-attenuated inversion recovery and magnetization-prepared rapid acquisition of gradient echo sequences in relation to conventional postcontrast T1-weighted images for the evaluation of leptomeningeal diseases at 3T.

Authors:  H Fukuoka; T Hirai; T Okuda; Y Shigematsu; A Sasao; E Kimura; T Hirano; S Yano; R Murakami; Y Yamashita
Journal:  AJNR Am J Neuroradiol       Date:  2009-12-24       Impact factor: 3.825

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.