Literature DB >> 8939232

Optimization of thoracic spiral CT: effects of iodinated contrast medium concentration.

G D Rubin1, M J Lane, D A Bloch, A N Leung, P Stark.   

Abstract

PURPOSE: To determine the effect of varying iodine concentration on arterial enhancement and perivenous artifact during thoracic spiral computed tomographic (CT) scanning.
MATERIALS AND METHODS: One hundred thirty-eight outpatients received 15.0 g (n = 76) or 22.5 g (n = 62) of iodine (300 mg/mL iodine) while undergoing thoracic spiral CT. Patients received either undiluted contrast medium, 1:1 normal saline dilution, or 3:1 normal saline dilution. Contrast medium was injected at a flow rate determined to deliver the entire iodine dose within 40 seconds. Attenuation was measured within arteries and veins. Three blinded thoracic radiologists independently graded perivenous artifact and arterial enhancement.
RESULTS: Perivenous artifacts were statistically significantly reduced with successive iodine dilution (P < .002). Arterial enhancement was statistically significantly better with 15.0 g of iodine diluted 1:1 when compared with the same iodine dose undiluted or diluted 3:1 (P < .01). Arterial enhancement achieved with 15.0 g of iodine diluted 1:1 was not statistically significantly lower than that achieved with 22.5 g of iodine diluted 1:1 (P > .31); however, venous artifact was greater with 22.5 g of iodine (P < .004).
CONCLUSION: Reduced iodine concentration appears to diminish perivenous artifact and to result in improved arterial enhancement during thoracic spiral CT.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8939232     DOI: 10.1148/radiology.201.3.8939232

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  5 in total

Review 1.  Spiral computed tomographic scanning and magnetic resonance angiography for the diagnosis of pulmonary embolism.

Authors:  P A Grenier; C Beigelman
Journal:  Thorax       Date:  1998-08       Impact factor: 9.139

2.  Contrast agent bolus tracking with a fixed threshold or a manual fast start for coronary CT angiography.

Authors:  Fabian Stenzel; Matthias Rief; Elke Zimmermann; Johannes Greupner; Felicitas Richter; Marc Dewey
Journal:  Eur Radiol       Date:  2014-03-26       Impact factor: 5.315

3.  Subjective and objective image differences in pediatric computed tomography cardiac angiography using lower iodine concentration.

Authors:  Jae-Yeon Hwang; Ki Seok Choo; Yoon Young Choi; Jin Hyeok Kim; Hwaseong Ryu; Junhee Han; Yong-Woo Kim; Ung Bae Jeon; Kyung Jin Nam
Journal:  Pediatr Radiol       Date:  2017-02-24

4.  Does pregnancy affect vascular enhancement in patients undergoing CT pulmonary angiography?

Authors:  Adrian K Andreou; John J Curtin; Sue Wilde; Allan Clark
Journal:  Eur Radiol       Date:  2008-07-24       Impact factor: 5.315

5.  Effect of region-of-interest placement in bolus tracking cerebral computed tomography angiography.

Authors:  Raymond Y Huang; Bob B Chai; Thomas C Lee
Journal:  Neuroradiology       Date:  2013-07-11       Impact factor: 2.804