Literature DB >> 8933068

Pulsed wave Doppler echocardiography in normal horses.

K J Blissitt1, J D Bonagura.   

Abstract

Reference values were established for selected Doppler derived variables from a group of 40 normal Thoroughbred and Thoroughbred cross horses. Standard two-dimensional (2-D) images used for guiding the Doppler sampling site allowed accurate alignment with flow. Tricuspid inflow velocities during rapid filling (E) and atrial contraction (A) were significantly higher when recorded from a right parasternal angled view than from a right parasternal long-axis view. In 8 horses the tricuspid inflow peak A velocity was higher than the peak E velocity. The peak acceleration of blood flow was higher (P = 0.000) in the aorta (mean 8.01 m/s/s) than in the pulmonary artery (4.45 m/s/s). Significant differences were also noted in the pre-ejection period, ejection time and acceleration time between the 2 vessels. Horses with functional ejection murmurs had lower peak aortic acceleration and a longer acceleration time than horses without flow murmurs. Horses with filling murmurs over the left hemithorax had a significantly higher peak mitral E velocity than horses without such murmurs. Measurements from Doppler waveforms were repeatable and may prove useful in assessing ventricular function in this species.

Entities:  

Mesh:

Year:  1995        PMID: 8933068     DOI: 10.1111/j.2042-3306.1995.tb04988.x

Source DB:  PubMed          Journal:  Equine Vet J Suppl


  6 in total

1.  Comparison of systolic cardiac function before and after treatment of atrial fibrillation in horses with and without additional cardiac valve insufficiencies.

Authors:  H Gehlen; P Stadler
Journal:  Vet Res Commun       Date:  2004-05       Impact factor: 2.459

2.  Echocardiographic Assessment of Left Ventricular Function in Healthy Horses and in Horses with Heart Disease Using Pulsed-Wave Tissue Doppler Imaging.

Authors:  T R Koenig; K J Mitchell; C C Schwarzwald
Journal:  J Vet Intern Med       Date:  2017-01-21       Impact factor: 3.333

3.  Three-dimensional and catheter-based intracardiac echocardiographic characterization of the interatrial septum in 2 horses with suspicion of a patent foramen ovale.

Authors:  Ingrid Vernemmen; Ellen Paulussen; Julie Dauvillier; Annelies Decloedt; Gunther van Loon
Journal:  J Vet Intern Med       Date:  2022-05-30       Impact factor: 3.175

4.  Investigating the Relationship Between Cardiac Function and Insulin Sensitivity in Horses: A Pilot Study.

Authors:  Natasha J Williams; Martin Furr; Cristobal Navas de Solis; Allison Campolo; Michael Davis; Véronique A Lacombe
Journal:  Front Vet Sci       Date:  2022-07-08

5.  Reference Values and Repeatability of Pulsed Wave Doppler Echocardiography Parameters in Normal Donkeys.

Authors:  Mohamed Marzok; Adel I Almubarak; Zakriya Al Mohamad; Mohamed Salem; Alshimaa M Farag; Hussam M Ibrahim; Maged R El-Ashker; Sabry El-Khodery
Journal:  Animals (Basel)       Date:  2022-09-05       Impact factor: 3.231

6.  Repeatability, variability and reference values of pulsed wave Doppler echocardiographic measurements in healthy Saanen goats.

Authors:  Aurélia A Leroux; Frédéric Farnir; Marie L Moonen; Charlotte F Sandersen; Stefan Deleuze; Hélène Amory
Journal:  BMC Vet Res       Date:  2012-10-16       Impact factor: 2.741

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.