| Literature DB >> 23067875 |
Aurélia A Leroux1, Frédéric Farnir, Marie L Moonen, Charlotte F Sandersen, Stefan Deleuze, Hélène Amory.
Abstract
BACKGROUND: Pulsed wave (PW) Doppler echocardiography has become a routine non invasive cardiac diagnostic tool in most species. However, evaluation of intracardiac blood flow requires reference values, which are poorly documented in goats. The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy adult Saanen goats. Using a standardised PW Doppler echocardiographic protocol, 10 healthy adult unsedated female Saanen goats were investigated three times at one day intervals by the same observer. Mitral, tricuspid, aortic and pulmonary flows were measured from a right parasternal view, and mitral and aortic flows were also measured from a left parasternal view. The difference between left and right side measurements and the intra-observer inter-day repeatability were tested and then the reference values of PW Doppler echocardiographic parameters in healthy adult female Saanen goats were established.Entities:
Mesh:
Year: 2012 PMID: 23067875 PMCID: PMC3488548 DOI: 10.1186/1746-6148-8-190
Source DB: PubMed Journal: BMC Vet Res ISSN: 1746-6148 Impact factor: 2.741
Figure 1Mitral inflow velocity spectrum obtained from a left parasternal long axis four chamber view. The peak early filling velocity (Emax), the peak filling velocity of the transmitral flow during atrial contraction (Amax), the E-peak and A-peak velocity time integral (VTIE and VTIA respectively) and the E-peak and A-peak ejection times (ETE and ETA respectively) were measured as shown.
Figure 2Aortic flow velocity spectrum obtained from a left parasternal long axis five chamber view. The peak velocity of the aortic flow (Vmax), the velocity time integral (VTI), the ejection time (ET), the time to peak velocity (TTP) and the pre-ejection period (PEP) of the aortic flow were measured as shown.
Figure 3Tricuspid inflow velocity spectrum obtained from a tilted right parasternal long axis four chamber view. The peak early filling velocity (Emax), the peak filling velocity of the tricuspid flow during atrial contraction (Amax), the E-peak and A-peak velocity time integral (VTIE and VTIA respectively) and the E-peak and A-peak ejection times (ETE and ETA respectively) were measured as shown.
Figure 4Pulmonary outflow velocity spectrum obtained from a right parasternal right ventricular inflow-outflow view. The peak velocity of the pulmonary flow (Vmax), the velocity time integral (VTI), the ejection time (ET), the time to peak velocity (TTP) and the pre-ejection period (PEP) of the pulmonary flow were measured as shown.
Comparison of pulse wave Doppler echocardiographic parameters of the aortic flow obtained on the right and on the left side in 10 healthy adult Saanen goats, and within-day and between-day variability of these measurements performed on 3 following days by the same observer
| Vmax (m/s) | 0.99 ± 0.006 | 1.11 ± 0.006 * | 1.05 ± 0.14 | 0.98 – 1.11 | 4.87 | 6.62 |
| Vmean (m/s) | 0.73 ± 0.004 | 0.79 ± 0.004 * | 0.76 ± 0.09 | 0.72 – 0.81 | 5.60 | 6.43 |
| ET (ms) | 266.89 ± 1.41 | 271.95 ± 1.40 * | 269.42 ± 23.17 | 254.38 – 284.45 | 4.68 | 6.37 |
| VTI (cm) | 19.58 ± 0.14 | 21.42 ± 0.14 * | 20.51 ± 2.77 | 18.98 – 22.03 | 6.76 | 8.47 |
| PEP (ms) | 49.80 ± 0.55 | 50.89 ± 0.55 | 50.38 ± 6.84 | 44.48 – 56.28 | 11.49 | 13.35 |
| TTP (ms) | 102.53 ± 1.57 | 82.74 ± 1.56 * | 92.58 ± 19.70 | 75.77 – 109.37 | 16.31 | 20.70 |
| Acc slope (m/s2) | 10.28 ± 0.24 | 13.95 ± 0.24 * | 12.13± 3.29 | 9.58 – 14.67 | 17.67 | 23.93 |
| Dec slope (m/s2) | 6.35 ± 0.08 | 6.067 ± 0.08 * | 6.21 ± 1.44 | 5.38 – 7.03 | 11.14 | 15.16 |
| Dec Time (ms) | 164.35 ± 1.79 | 189.21 ± 1.78 * | 176.85 ± 26.82 | 157.68 – 196.01 | 10.30 | 12.36 |
| SV (ml) | 61.77 ± 0.45 | 67.61 ± 0.45 * | 64.71 ± 8.60 | 59.87 – 69.55 | 6.76 | 8.52 |
| CO (l/min) | 5.80 ± 0.44 | 6.16 ± 0.44 * | 5.98 ± 0.96 | 5.51 – 6.45 | 6.76 | 8.46 |
| SI (ml/kg) | 0.96 ± 0.007 | 1.05 ± 0.007 * | 1.00 ± 0.14 | 0.92 – 1.08 | 6.76 | 8.98 |
| CI (ml/kg/min) | 89.81 ± 0.72 | 95.27 ± 0.72 * | 92.45 ± 14.91 | 84.78 – 100.11 | 6.76 | 8.82 |
| PEP/ET | 0.19 ± 0.003 | 0.19 ± 0.003 | 0.19 ± 0.03 | 0.16 – 0.22 | 13.37 | 9.46 |
Acc: Acceleration, CI: Cardiac Index, CO: Cardiac output, CV: Coefficient of variation, Dec: Deceleration, ET: Ejection time of the aortic flow, LSMean: Least Square Mean, PEP: Pre-ejection period of the aortic flow, SD: Standard deviation, SE: Standard error, SI: Stroke index, SV: Stroke volume, TPP: Time to peak of the aortic flow, Vmax: Peak velocity of the aortic flow, Vmean: Mean velocity of the aortic flow, VTI: Velocity time integral of the aortic flow.
* Significantly different from corresponding value obtained from the right side, p < 0.05.
Comparison of pulse wave Doppler echocardiographic parameters of the mitral flow obtained on the right and on the left side in 10 healthy adult Saanen goats, and within-day and between-day variability of these measurements performed on 3 following days by the same observer
| | | | | | | |
| Emax (m/s) | 0.57 ± 0.005 | 0.59 ± 0.005 * | 0.58 ± 0.04 | 0.52 – 0.63 | 7.23 | 10.66 |
| Emean (m/s) | 0.40 ± 0.004 | 0.42 ± 0.004 * | 0.41 ± 0.03 | 0.37 – 0.45 | 7.97 | 10.80 |
| VTI (cm) | 8.84 ± 0.10 | 9.52 ± 0.10 * | 9.18 ± 0.97 | 8.07 – 10.29 | 10.52 | 13.81 |
| ET (ms) | 224.57 ± 2.52 | 227.54 ± 2.52 | 226.06 ± 22.17 | 199.01 – 253.11 | 9.91 | 13.65 |
| Dec Time (ms) | 119.99 ± 1.95 | 104.99 ± 1.95 * | 112.49 ± 19.12 | 91.56 – 133.41 | 17.75 | 21.22 |
| Dec slope (m/s2) | 5.17 ± 0.20 | 6.74 ± 0.20 * | 5.96 ± 1.45 | 3.78 – 8.13 | 22.35 | 41.53 |
| | | | | | | |
| Amax (m/s) | 0.51 ± 0.005 | 0.52 ± 0.005 | 0.51 ± 0.05 | 0.46 – 0.56 | 10.24 | 11.50 |
| Amean (m/s) | 0.39 ± 0.004 | 0.39 ± 0.004 | 0.39 ± 0.04 | 0.34 – 0.43 | 11.42 | 12.79 |
| VTI (cm) | 4.27 ± 0.06 | 4.26 ± 0.06 | 4.27 ± 0.64 | 3.61 – 4.92 | 14.98 | 17.43 |
| ET (ms) | 110.74 ± 1.44 | 110.44 ± 1.44 | 110.59 ± 14.76 | 95.17 – 126.01 | 13.26 | 15.90 |
| Emax/Amax | 1.12 ± 0.01 | 1.15 ± 0.01 | 1.14 ± 0.11 | 1.01 – 1.26 | 9.31 | 12.35 |
Amax: peak velocity of the mitral flow during the atrial contraction, Amean: mean velocity of the mitral flow during the atrial contraction, CV: Coefficient of variation, Dec: Deceleration, Emax: peak velocity of the mitral flow during the early ventricular filling, Emean: mean velocity of the mitral flow during the early ventricular filling, ET: Ejection time, LSMean: Least Square Mean, SD: Standard deviation, SE: Standard error, VTI: Velocity time integral.
* Significantly different from corresponding value obtained from the right side, p < 0.05.
Within-day and between-day variability and confidence interval of pulse wave Doppler echocardiographic measurements of the pulmonary flow in 10 healthy adult Saanen goats performed 3 times at 1 day interval by the same observer
| Vmax (m/s) | 0.99 ± 0.12 | 0.93 – 1.05 | 5.33 | 6.19 |
| Vmean (m/s) | 0.76 ± 0.10 | 0.71 – 0.80 | 5.49 | 6.58 |
| ET (ms) | 266.7 ± 23.4 | 254.45 – 279.04 | 4.77 | 5.26 |
| VTI (cm) | 20.14 ± 2.74 | 19.02 – 21.25 | 6.03 | 6.31 |
| PEP (ms) | 51.1 ± 8.0 | 44.89 – 57.39 | 12.34 | 13.94 |
| TTP (ms) | 112.5 ± 27.1 | 95.57 – 129.44 | 15.89 | 17.17 |
| Acc slope (m/s2) | 9.31 ± 2.83 | 7.35 – 11.27 | 20.19 | 24.02 |
| Dec slope (m/s2) | 6.81 ± 1.97 | 5.71 – 7.91 | 12.54 | 18.36 |
| Dec Time (ms) | 154.3 ± 31.9 | 136.44 – 172.05 | 12.48 | 13.17 |
| SV (ml) | 77.69 ± 11.16 | 73.41 – 81.97 | 6.02 | 6.28 |
| CO (l/min) | 7.34 ± 1.50 | 6.93 – 7.74 | 6.02 | 6.30 |
| SI (ml/kg) | 1.20 ± 0.17 | 1.13 – 1.27 | 6.02 | 6.47 |
| CI (ml/kg/min) | 113.31 ± 22.88 | 106.82 – 119.80 | 6.02 | 6.53 |
| PEP/ET | 0.19 ± 0.04 | 0.16 – 0.22 | 14.86 | 16.41 |
Acc: Acceleration, CI: Cardiac index, CO: Cardiac output, CV: Coefficient of variation, Dec: Deceleration, ET: Ejection time of the pulmonary flow, PEP: Pre-ejection period of the pulmonary flow, SD: Standard deviation, SI: Stroke index, SV: Stroke volume, TPP: Time to peak of the pulmonary flow, Vmax: Peak velocity of the pulmonary flow, Vmean: Mean velocity of the pulmonary flow, VTI: Velocity time integral of the pulmonary flow.
Within-day and between-day variability and confidence interval of pulse wave Doppler echocardiographic measurements of the tricuspid flow in 10 healthy adult Saanen goats performed 3 times at 1 day interval by the same observer
| | | | | |
| Emax (m/s) | 0.67 ± 0.15 | 0.60 – 0.73 | 9.82 | 10.34 |
| Emean (m/s) | 0.49 ± 0.12 | 0.44 – 0.54 | 10.11 | 10.88 |
| VTI (cm) | 10.60 ± 3.10 | 9.14 – 12.06 | 15.21 | 15.69 |
| ET (ms) | 220.6 ± 54.5 | 196.34 – 244.77 | 11.16 | 12.53 |
| Dec Time (ms) | 108.9 ± 34.7 | 86.23 – 131.72 | 22.03 | 23.81 |
| Dec slope (m/s2) | 6.89 ± 3.09 | 5.02 – 8.74 | 25.65 | 30.87 |
| | | | | |
| Amax (m/s) | 0.58 ± 0.12 | 0.51 – 0.64 | 10.70 | 12.29 |
| Amean (m/s) | 0.45 ± 0.10 | 0.39 – 0.49 | 11.07 | 12.60 |
| VTI (cm) | 5.11 ± 1.24 | 4.30 – 5.91 | 16.20 | 17.97 |
| ET (ms) | 117.3 ± 24.2 | 103.86 – 130.77 | 11.41 | 13.08 |
| E/A | 1.16 ± 0.19 | 1.03 – 1.29 | 11.14 | 12.35 |
Amax: peak velocity of the tricuspid flow during the atrial contraction, Amean: mean velocity of the tricuspid flow during the atrial contraction, CI: Confidence Intervals, CV: Coefficient of variation, Dec: Deceleration, Emax: peak velocity of the tricuspid flow during the early ventricular filling, Emean: mean velocity of the tricuspid flow during the early ventricular filling, ET: Ejection time, SD: Standard deviation, VTI: Velocity time integral.