Literature DB >> 8929304

Evaluation of image quality using 1 : 1 pitch and 1.5 : 1 pitch helical CT in children: a comparative study.

A Vade1, T C Demos, M C Olson, P Subbaiah, R C Turbin, K Vickery, K Corrigan.   

Abstract

OBJECTIVE: The objective of this study was to compare the quality of 1 : 1 and 1.5 : 1 pitch helical contrast-enhanced thoracic and abdominal CT images in children who cannot cooperate for breath holding.
MATERIALS AND METHODS: This is a retrospective study of 33 contrast-enhanced CT examinations in 11 children of 0-4 years of age. All children had an initial CT study using 1 : 1 pitch helical scanning followed over the next 6-36 months by one to four CT examinations with 1.5 : 1 pitch. Radiation dose with the two techniques was measured with a pencil ionization chamber.
RESULTS: The two techniques provided comparable overall image quality. There was 33 % less radiation dose with 1.5 : 1 pitch helical scanning.
CONCLUSION: The 1.5 : 1 pitch helical CT provides comparable quality images and a smaller radiation dose than 1 : 1 pitch in examining children aged 0-4 years.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8929304     DOI: 10.1007/bf03178045

Source DB:  PubMed          Journal:  Pediatr Radiol        ISSN: 0301-0449


  9 in total

1.  Spiral CT: decreased spatial resolution in vivo due to broadening of section-sensitivity profile.

Authors:  J A Brink; J P Heiken; D M Balfe; S S Sagel; J DiCroce; M W Vannier
Journal:  Radiology       Date:  1992-11       Impact factor: 11.105

2.  Evaluation of section sensitivity profiles and image noise in spiral CT.

Authors:  A Polacin; W A Kalender; G Marchal
Journal:  Radiology       Date:  1992-10       Impact factor: 11.105

3.  Spiral CT of the pancreas.

Authors:  D E Dupuy; P Costello; C P Ecker
Journal:  Radiology       Date:  1992-06       Impact factor: 11.105

4.  Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation.

Authors:  W A Kalender; W Seissler; E Klotz; P Vock
Journal:  Radiology       Date:  1990-07       Impact factor: 11.105

Review 5.  Spiral (helical) CT.

Authors:  J P Heiken; J A Brink; M W Vannier
Journal:  Radiology       Date:  1993-12       Impact factor: 11.105

6.  CT of the chest and abdomen in patients on mechanical pulmonary ventilators: quality of images made at 0.6 vs 1.0 sec.

Authors:  H V Posniak; M C Olson; T C Demos; K L Pierce; C L Kalbhen
Journal:  AJR Am J Roentgenol       Date:  1994-11       Impact factor: 3.959

7.  Pulmonary nodule: evaluation with spiral volumetric CT.

Authors:  P Costello; W Anderson; D Blume
Journal:  Radiology       Date:  1991-06       Impact factor: 11.105

8.  Detection of focal hepatic lesions with spiral CT: comparison of 4- and 8-mm interscan spacing.

Authors:  B A Urban; E K Fishman; J E Kuhlman; A Kawashima; J G Hennessey; S S Siegelman
Journal:  AJR Am J Roentgenol       Date:  1993-04       Impact factor: 3.959

9.  Pulmonary nodules: detection with thick-section spiral CT versus conventional CT.

Authors:  M Remy-Jardin; J Remy; F Giraud; C H Marquette
Journal:  Radiology       Date:  1993-05       Impact factor: 11.105

  9 in total
  6 in total

1.  Strategies of dose reduction.

Authors:  Donald P Frush
Journal:  Pediatr Radiol       Date:  2002-03-07

2.  Effective doses to adult and pediatric patients.

Authors:  Walter Huda
Journal:  Pediatr Radiol       Date:  2002-03-06

3.  Correlation of patient weight and cross-sectional dimensions with subjective image quality at standard dose abdominal CT.

Authors:  Mannudeep K Kalra; Michael M Maher; Srinivasa R Prasad; M Sikandar Hayat; Michael A Blake; Jose Varghese; Elkan F Halpern; Sanjay Saini
Journal:  Korean J Radiol       Date:  2003 Oct-Dec       Impact factor: 3.500

Review 4.  Dosimetry of FDG PET/CT and other molecular imaging applications in pediatric patients.

Authors:  Michael J Gelfand
Journal:  Pediatr Radiol       Date:  2008-12-16

Review 5.  Pediatric liver tumors--a pictorial review.

Authors:  Priyanka Jha; Soni C Chawla; Sidhartha Tavri; Chirag Patel; Charles Gooding; Heike Daldrup-Link
Journal:  Eur Radiol       Date:  2008-08-06       Impact factor: 5.315

Review 6.  The radiation burden of radiological investigations.

Authors:  W Mazrani; K McHugh; P J Marsden
Journal:  Arch Dis Child       Date:  2007-12       Impact factor: 3.791

  6 in total