Literature DB >> 1410356

Spiral CT: decreased spatial resolution in vivo due to broadening of section-sensitivity profile.

J A Brink1, J P Heiken, D M Balfe, S S Sagel, J DiCroce, M W Vannier.   

Abstract

Comparable conventional and spiral computed tomographic (CT) scanning protocols for transaxial (n = 30) and multiplanar reformation (MPR) (n = 15) imaging were performed to image the adrenal gland and the upper pole of the right kidney in the same patient, without use of intravenously administered contrast media. The sharpness of soft-tissue-fat interfaces oriented in the transverse (xy) and longitudinal (z) directions was measured as the maximum and full width at half maximum (FWHM) of the edge attenuation profile first derivative. Edge sharpness was qualitatively assessed by three blinded reviewers, who used a four-point scale. In vivo transaxial CT studies showed that the conventional scans produced slightly sharper edges than the spiral scans (mean difference of spiral and conventional FWHM = 0.30 mm [P < .05] [in z direction] and 0.21 mm [P < .05] [in xy direction]). In vivo MPR studies showed that interfaces in the xy plane were significantly less sharp with spiral scanning, whereas interfaces in the z direction were equivalent for conventional and spiral scanning (mean difference of spiral and conventional FWHM = 0.03 mm [P > .05] [in z direction] and 1.19 mm [P < .05] [in xy direction]). Significant respiratory misregistration was present on seven of 15 (47%) conventional MPR scans and on no spiral MPR scans.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1410356     DOI: 10.1148/radiology.185.2.1410356

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  3 in total

1.  3D reconstruction techniques made easy: know-how and pictures.

Authors:  Giacomo Luccichenti; Filippo Cademartiri; Francesca Romana Pezzella; Giuseppe Runza; Manuel Belgrano; Massimo Midiri; Umberto Sabatini; Stefano Bastianello; Gabriel P Krestin
Journal:  Eur Radiol       Date:  2005-04-05       Impact factor: 5.315

2.  Fully automated system for three-dimensional bronchial morphology analysis using volumetric multidetector computed tomography of the chest.

Authors:  Raman Venkatraman; Raghav Raman; Bhargav Raman; Richard B Moss; Geoffrey D Rubin; Lawrence H Mathers; Terry E Robinson
Journal:  J Digit Imaging       Date:  2006-06       Impact factor: 4.056

3.  Evaluation of image quality using 1 : 1 pitch and 1.5 : 1 pitch helical CT in children: a comparative study.

Authors:  A Vade; T C Demos; M C Olson; P Subbaiah; R C Turbin; K Vickery; K Corrigan
Journal:  Pediatr Radiol       Date:  1996-12