Literature DB >> 8925852

Measurement of liver blood flow using oxygen-15 labelled water and dynamic positron emission tomography: limitations of model description.

S I Ziegler1, U Haberkorn, H Byrne, C Tong, S Kaja, J A Richolt, H Byrne, C Tong, R Schosser, H Krieter, S Kaja, J A Richolt, A A Lammertsma, P Price.   

Abstract

To date no satisfactory method has been available for the quantitative in vivo measurement of the complex hepatic blood flow. In this study two modelling approaches are proposed for the analysis of liver blood flow using positron emission tomography (PET). Five experiments were performed on three foxhounds. The anaesthetised dogs were each given an intravenous bolus injection of oxygen-15 labelled water, and their livers were then scanned using PET. Radioactivity in the blood from the aorta and portal vein was measured directly and simultaneously using closed external circuits. Time-activity curves were constructed from sequential PET data. Data analysis was performed by assuming that water behaves as a freely diffusible tracer and adapting the standard one-compartment blood flow model to describe the dual blood supply of the liver. Two particular modelling approaches were investigated: the dual-input model used both directly measured input functions (i.e. using the hepatic artery and the portal vein input, determined from the radioactivity detected in the aorta and portal vein respectively) whereas the single-input model used only the measured arterial curve and predicted the corresponding portal input function. Hepatic arterial flow, portal flow and blood volume were fitted from the PET data in several regions of the liver. The resulting estimates were then compared with reference blood flow measurements, obtained using a standard microsphere technique. The microspheres were injected in a separate experiment on the same dogs immediately prior to PET scanning. Whilst neither the single- nor the dual-input models accurately reproduced the arterial reference flow values, the flow values from the single-input model were closer to the microsphere flow values. The proposed single-input model would be a good approximation for liver blood flow measurements in man. The observed discrepancies between the PET and microsphere flow values may be due to the inherent temporal and spatial heterogeneity of liver blood flow. The results presented suggest that adaptation of the standard one-compartment blood flow model to describe the dual blood supply of the liver is limited and other flow tracers have to be considered for quantitative PET measurements in the liver.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8925852     DOI: 10.1007/bf01731841

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  26 in total

1.  A simple technique of measuring liver blood flow--intrasplenic injection of 133Xenon.

Authors:  P H Lam; R T Mathie; A M Harper; L H Blumgart
Journal:  Acta Chir Scand       Date:  1979

2.  Measurement of cerebral blood flow with a bolus of oxygen-15-labelled water: comparison of dynamic and integral methods.

Authors:  A Bol; P Vanmelckenbeke; C Michel; M Cogneau; A M Goffinet
Journal:  Eur J Nucl Med       Date:  1990

3.  Methodological error and spatial variability of organ blood flow measurements using radiolabeled microspheres.

Authors:  B Zwissler; R Schosser; C Weiss; V Iber; M Weiss; C Schwickert; P Spengler; K Messmer
Journal:  Res Exp Med (Berl)       Date:  1991

4.  Simultaneous correction for tracer arrival delay and dispersion in CBF measurements by the H215O autoradiographic method and dynamic PET.

Authors:  E Meyer
Journal:  J Nucl Med       Date:  1989-06       Impact factor: 10.057

Review 5.  Hepatic vascular bed.

Authors:  C V Greenway; R D Stark
Journal:  Physiol Rev       Date:  1971-01       Impact factor: 37.312

6.  Determination of liver and spleen perfusion by quantitative sequential scintigraphy: results in normal subjects and in patients with portal hypertension.

Authors:  H J Biersack; J Torres; M Thelen; O Monzon; C Winkler
Journal:  Clin Nucl Med       Date:  1981-05       Impact factor: 7.794

7.  Brain blood flow measured with intravenous H2(15)O. I. Theory and error analysis.

Authors:  P Herscovitch; J Markham; M E Raichle
Journal:  J Nucl Med       Date:  1983-09       Impact factor: 10.057

8.  MIC-III--an integrated software package to support experiments using the radioactive microsphere technique.

Authors:  W Gross; R Schosser; K Messmer
Journal:  Comput Methods Programs Biomed       Date:  1990-10       Impact factor: 5.428

9.  Blood supply and drug delivery to primary and secondary human liver cancers studied with in vivo bromodeoxyuridine labeling.

Authors:  H Taniguchi; T Daidoh; Y Shioaki; T Takahashi
Journal:  Cancer       Date:  1993-01-01       Impact factor: 6.860

10.  Quantification of regional myocardial blood flow in vivo with H215O.

Authors:  S R Bergmann; K A Fox; A L Rand; K D McElvany; M J Welch; J Markham; B E Sobel
Journal:  Circulation       Date:  1984-10       Impact factor: 29.690

View more
  7 in total

Review 1.  Use of positron emission tomography in anticancer drug development.

Authors:  Eric O Aboagye; Patricia M Price
Journal:  Invest New Drugs       Date:  2003-05       Impact factor: 3.850

2.  Quantitative tissue blood flow measurement of the liver parenchyma: comparison between xenon CT and perfusion CT.

Authors:  Kazuhiko Hashimoto; Takamichi Murakami; Keizo Dono; Masatoshi Hori; Tonsok Kim; Masayuki Kudo; Shigeru Marubashi; Atsushi Miyamoto; Yutaka Takeda; Hiroaki Nagano; Koji Umeshita; Hironobu Nakamura; Morito Monden
Journal:  Dig Dis Sci       Date:  2007-02-23       Impact factor: 3.199

3.  Non-invasive diagnosis of acute mesenteric ischaemia using PET.

Authors:  Jan Kiss; Alexandru Naum; Nobuyuki Kudomi; Juhani Knuuti; Patricia Iozzo; Timo Savunen; Pirjo Nuutila
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03-11       Impact factor: 9.236

4.  Non-invasive estimation of hepatic blood perfusion from H2 15O PET images using tissue-derived arterial and portal input functions.

Authors:  N Kudomi; L Slimani; M J Järvisalo; J Kiss; R Lautamäki; G A Naum; T Savunen; J Knuuti; H Iida; P Nuutila; P Iozzo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-05-06       Impact factor: 9.236

5.  The precise physiological definition of tissue perfusion and clearance measured from imaging.

Authors:  A Michael Peters
Journal:  Eur J Nucl Med Mol Imaging       Date:  2018-07       Impact factor: 9.236

Review 6.  Hepatic Positron Emission Tomography: Applications in Metabolism, Haemodynamics and Cancer.

Authors:  Miikka-Juhani Honka; Eleni Rebelos; Simona Malaspina; Pirjo Nuutila
Journal:  Metabolites       Date:  2022-04-02

7.  Blood flow and glucose metabolism in stage IV breast cancer: heterogeneity of response during chemotherapy.

Authors:  Nanda Krak; Jacobus van der Hoeven; Otto Hoekstra; Jos Twisk; Elsken van der Wall; Adriaan Lammertsma
Journal:  Mol Imaging Biol       Date:  2008-08-16       Impact factor: 3.488

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.