Literature DB >> 8915782

In vivo reproducibility of three-dimensional structural properties of noninvasive bone biopsies using 3D-pQCT.

R Müller1, T Hildebrand, H J Häuselmann, P Rüegsegger.   

Abstract

Trabecular bone architecture is one of the main factors influencing the mechanical behavior of cancellous bone. To assess the three-dimensional trabecular microstructure of intact bones, we introduced the concept of noninvasive bone biopsy, a method to assess and analyze cancellous bone based upon three-dimensional peripheral quantitative computed tomography in vivo (3D-pQCT). The aim of this work was to demonstrate the potential of noninvasive bone biopsies as a basis for structural and mechanical analysis of trabecular bone in the process of rapid bone loss. A group of six healthy young male volunteers was measured to provide data on the reproducibility of structural parameters. Baseline and 1-month follow-up measurements were performed to provide data on short-term precision of the procedure, and three of the controls were reanalyzed within 3-6 months to estimate long-term precision. Prior to structural evaluation, the baseline and follow-up measurements were repositioned three-dimensionally to ensure matching volumes of interest (VOI). Trabecular bone density (TBD) as well as structural indices were analyzed for all measurements. The VOIs were analyzed morphometrically by evaluating bone volume (BV/TV) and trabecular number (Tb.N) based on a direct three-dimensional approach. Trabecular thickness (Tb.Th) and trabecular separation (Tb.Sp) were derived from these two indices. The data of the measurements at 1 month to determine the short-term precision was in excellent agreement with the baseline measurements. The results showed that structural parameters can be reproduced in vivo with a coefficient of variation of less than 0.5%. With a typical spread of 4% for the structural indices within the group of healthy volunteers, an intraclass correlation of better than 0.98 was reached. We conclude that high-resolution 3D-pQCT has the potential to detect structural changes in trabecular bone during therapeutic and diagnostic trials.

Entities:  

Mesh:

Year:  1996        PMID: 8915782     DOI: 10.1002/jbmr.5650111118

Source DB:  PubMed          Journal:  J Bone Miner Res        ISSN: 0884-0431            Impact factor:   6.741


  34 in total

1.  Bone microarchitecture assessment: current and future trends.

Authors:  Ralph Müller
Journal:  Osteoporos Int       Date:  2003-08-29       Impact factor: 4.507

2.  Short-term in vivo precision of BMD and parameters of trabecular architecture at the distal forearm and tibia.

Authors:  K Engelke; B Stampa; W Timm; B Dardzinski; A E de Papp; H K Genant; T Fuerst
Journal:  Osteoporos Int       Date:  2011-12-06       Impact factor: 4.507

3.  Quantitative characterization of subject motion in HR-pQCT images of the distal radius and tibia.

Authors:  Miki Sode; Andrew J Burghardt; Jean-Baptiste Pialat; Thomas M Link; Sharmila Majumdar
Journal:  Bone       Date:  2011-03-21       Impact factor: 4.398

Review 4.  Current technologies in the evaluation of bone architecture.

Authors:  Sharmila Majumdar
Journal:  Curr Osteoporos Rep       Date:  2003-12       Impact factor: 5.096

Review 5.  Recent developments in trabecular bone characterization using ultrasound.

Authors:  Frédéric Padilla; Pascal Laugier
Journal:  Curr Osteoporos Rep       Date:  2005-06       Impact factor: 5.096

Review 6.  Current diagnostic techniques in the evaluation of bone architecture.

Authors:  Thomas M Link; Sharmila Majumdar
Journal:  Curr Osteoporos Rep       Date:  2004-06       Impact factor: 5.096

Review 7.  Trabecular bone failure at the microstructural level.

Authors:  Ralph Müller; G Harry van Lenthe
Journal:  Curr Osteoporos Rep       Date:  2006-06       Impact factor: 5.096

8.  Texture analysis of X-ray radiographs of iliac bone is correlated with bone micro-CT.

Authors:  P Guggenbuhl; F Bodic; L Hamel; M F Baslé; D Chappard
Journal:  Osteoporos Int       Date:  2006-01-14       Impact factor: 4.507

9.  Accuracy of individual trabecula segmentation based plate and rod finite element models in idealized trabecular bone microstructure.

Authors:  Hong Wang; X Sherry Liu; Bin Zhou; Ji Wang; Baohua Ji; Yonggang Huang; Keh-Chih Hwang; X Edward Guo
Journal:  J Biomech Eng       Date:  2013-04       Impact factor: 2.097

10.  Use of dual-energy computed tomography to measure skeletal-wide marrow composition and cancellous bone mineral density.

Authors:  Luke Arentsen; Karen E Hansen; Masashi Yagi; Yutaka Takahashi; Ryan Shanley; Angela McArthur; Patrick Bolan; Taiki Magome; Douglas Yee; Jerry Froelich; Susanta K Hui
Journal:  J Bone Miner Metab       Date:  2016-12-09       Impact factor: 2.626

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.