Literature DB >> 8914870

Differences of regional coronary flow reserve assessed by adenosine thallium-201 scintigraphy early and six months after successful percutaneous transluminal coronary angioplasty or stent implantation.

F Versaci1, F Tomai, F Nudi, A Gaspardone, A De Fazio, M Ciavolella, F Crea, L Mango, L Chiariello, P A Gioffrè.   

Abstract

This study assesses regional coronary flow reserve using adenosine thallium-201 scintigraphy early and 6 months after angiographically successful percutaneous transluminal coronary angioplasty (PTCA) or stent implantation. Seventeen consecutive men with a significant isolated left anterior descending coronary artery stenosis were scheduled for repeat coronary angiography and adenosine-planar thallium-201 scintigraphy within 24 hours and 6 months after successful PTCA (n = 8) or stent implantation (n = 9). After background subtraction, left ventricular segmental uptake was semiquantitatively assessed on thallium images. The perfusion defect severity was scored from 0 (normal) to 3. Coronary angiograms were analyzed using an automated edge contour detection computer analysis system. Data are expressed as mean value +/- 1 SD, and proportions as percentage. The residual narrowing was 17 +/- 8% after PTCA and 9 +/- 2% after stent implantation (p = 0.02). Twenty-four hours after the procedure, hypoperfused segments were detected in all patients (100%) and in 4 patients (44%) (p = 0.05), respectively. The total number of hypoperfused segments was greater after PTCA than after stent implantation (16 [40%] vs 7 [16%], p = 0.001, respectively) as was the perfusion defect severity (4.4 +/- 3.1 vs 1 +/- 1.2, p = 0.006). Six months after the procedure, 3 of the 5 patients who had undergone PTCA without restenosis still had reversible perfusion defects. None of the stent-treated patients had restenosis or reversible perfusion defects (p = 0.05). Among PTCA-treated patients without restenosis, the total number of hypoperfused segments and the perfusion defect severity were 9 of 25 (36%) and 0.8 +/- 0.8, respectively. Thus, a regional reduction in coronary flow reserve, occasionally observed early after successful stent implantation, is probably due to a transient alteration of small coronary vessels, as was also supported by the absence of perfusion defects 6 months after the procedure. The more severe impairment of regional coronary flow reserve observed early after successful PTCA is probably also due to angiographic underestimation of the residual stenosis, as suggested also by the persistence of reversible perfusion defects 6 months after the procedure in a few patients.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8914870     DOI: 10.1016/s0002-9149(96)90059-4

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  2 in total

1.  Reversible defects on myocardial perfusion imaging early after coronary stent implantation: a predictor of late restenosis.

Authors:  Dae-Weung Kim; Soon-Ah Park; Chang-Guhn Kim; Cheol Lee; Seok Kyu Oh; Jin-Won Jeong
Journal:  Int J Cardiovasc Imaging       Date:  2008-03-13       Impact factor: 2.357

2.  Role of Stress Myocardial Scintigraphy in the Evaluation of Incompletely Revascularized Post-PCI Patients.

Authors:  Alfredo R Galassi; Francesco Marzá; Salvatore Azzarelli; Salvatore D Tomasello
Journal:  Int J Mol Imaging       Date:  2011-09-21
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.