Literature DB >> 18338236

Reversible defects on myocardial perfusion imaging early after coronary stent implantation: a predictor of late restenosis.

Dae-Weung Kim1, Soon-Ah Park, Chang-Guhn Kim, Cheol Lee, Seok Kyu Oh, Jin-Won Jeong.   

Abstract

PURPOSE: If coronary artery was treated with optimal stent implantation, myocardial perfusion in the territory supplied by a dilated coronary artery should be not reversible. However, several studies have demonstrated reversible perfusion in the territory supplied by a coronary artery with an optimally implanted stent. The main objective of this study was to evaluate the incidence of reversible defects detected by M-SPECT early after optimal PTCA with stent implantation. Its second objective was to determine the predictive value of detecting reversible defects after stent implantation for late restenosis.
METHODS: About 66 patients that underwent M-SPECT within 24 h of successful PTCA with stent implantation were included. All patients were followed up clinically and angiographically. The incidence of reversible perfusion defects on M-SPECT and the rate of late restenosis in target coronary arteries were evaluated retrospectively.
RESULTS: Reversible perfusion defects on M-SPECT were observed in 26% of the patients and in 36% of lesions following successful PTCA with stent implantation. The incidence of late restenosis was significantly higher in patients and lesions with reversible perfusion defects (47% vs. 18%). According to binary logistic regression analysis, the presence of a reversible perfusion defects was the only independent predictor of late restenosis.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18338236     DOI: 10.1007/s10554-007-9273-1

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  29 in total

1.  Long-term endothelial dysfunction after coronary artery stenting.

Authors:  P R Caramori; V C Lima; P H Seidelin; G E Newton; J D Parker; A G Adelman
Journal:  J Am Coll Cardiol       Date:  1999-11-15       Impact factor: 24.094

2.  A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association.

Authors:  W G Austen; J E Edwards; R L Frye; G G Gensini; V L Gott; L S Griffith; D C McGoon; M L Murphy; B B Roe
Journal:  Circulation       Date:  1975-04       Impact factor: 29.690

3.  Very early prediction of restenosis after successful coronary angioplasty: how early is early and can we identify it?

Authors:  D R Holmes
Journal:  J Am Coll Cardiol       Date:  1990-02       Impact factor: 24.094

4.  Predicting late restenosis after coronary angioplasty by very early (12 to 24 h) thallium-201 scintigraphy: implications with regard to mechanisms of late coronary restenosis.

Authors:  R Hardoff; A Shefer; S Gips; A Merdler; M Y Flugelman; D A Halon; B S Lewis
Journal:  J Am Coll Cardiol       Date:  1990-06       Impact factor: 24.094

5.  Redistribution in thallium-201 myocardial imaging soon after successful coronary stenting--tomographic evaluation during coronary hyperemia induced by adenosine.

Authors:  H Nagaoka; T Iizuka; S Kubota; M Inoue; E Yamaguchi; T Suzuki; R Nagai
Journal:  Jpn Circ J       Date:  1998-03

Review 6.  Acute stent thrombosis associated with exercise testing after successful percutaneous transluminal coronary angioplasty.

Authors:  B Samuels; J Schumann; H Kiat; J Friedman; D S Berman
Journal:  Am Heart J       Date:  1995-11       Impact factor: 4.749

7.  Myocardial perfusion abnormalities early (12-24 h) after coronary stenting or balloon angioplasty: implications regarding pathophysiology and late clinical outcome.

Authors:  Ronen Jaffe; Simona Ben Haim; Basheer Karkabi; Avi Front; Sara Gips; Giora Weisz; Nader Khader; Amnon Merdler; Moshe Y Flugelman; David A Halon; Basil S Lewis
Journal:  Cardiology       Date:  2002       Impact factor: 1.869

8.  Differences of regional coronary flow reserve assessed by adenosine thallium-201 scintigraphy early and six months after successful percutaneous transluminal coronary angioplasty or stent implantation.

Authors:  F Versaci; F Tomai; F Nudi; A Gaspardone; A De Fazio; M Ciavolella; F Crea; L Mango; L Chiariello; P A Gioffrè
Journal:  Am J Cardiol       Date:  1996-11-15       Impact factor: 2.778

9.  Frequency of adverse clinical events in the 12 months following successful intracoronary stent placement in patients treated with aspirin and ticlopidine (without warfarin).

Authors:  P B Berger; M R Bell; D E Grill; S Melby; D R Holmes
Journal:  Am J Cardiol       Date:  1998-03-15       Impact factor: 2.778

10.  A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease. Stent Restenosis Study Investigators.

Authors:  D L Fischman; M B Leon; D S Baim; R A Schatz; M P Savage; I Penn; K Detre; L Veltri; D Ricci; M Nobuyoshi
Journal:  N Engl J Med       Date:  1994-08-25       Impact factor: 91.245

View more
  2 in total

1.  Diagnostic value of myocardial SPECT to detect in-stent restenosis after drug-eluting stent implantation.

Authors:  Hyo Eun Park; Bon-Kwon Koo; Kyung-Woo Park; Jin Chul Paeng; Hae-Young Lee; Hyun-Jae Kang; Hyo-Soo Kim
Journal:  Int J Cardiovasc Imaging       Date:  2012-03-07       Impact factor: 2.357

2.  Myocardial Perfusion SPECT Imaging in Patients after Percutaneous Coronary Intervention.

Authors:  Panagiotis Georgoulias; Varvara Valotassiou; Ioannis Tsougos; Nikolaos Demakopoulos
Journal:  Curr Cardiol Rev       Date:  2010-05
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.