Literature DB >> 8912782

Improved arterial oxygenation after oleic acid lung injury in the pig using a computer-controlled mechanical ventilator.

G R Lefevre1, S E Kowalski, L G Girling, D B Thiessen, W A Mutch.   

Abstract

We compared computer-controlled mechanical ventilation programmed for biologic variability of respiratory rate (RR) and tidal volume (VT) with conventional intermittent positive-pressure ventilation (IPPV) in an oleic acid (OA) lung injury model. Seventeen pigs were ventilated with an Ohio 7000 anesthesia ventilator. Minute ventilation (VE) was adjusted to maintain PaCO2 at 30 to 35 mm Hg at baseline and was not altered further. OA was infused at 0.2 ml/kg/h until PaO2 decreased to < 125 mm Hg (F(I)O2 = 0.5). Animals were randomly assigned to continue with conventional IPPV (control group; n = 8) or had IPPV computer-controlled (computer group; n = 9). Hemodynamic, respiratory gas, airway pressure, and volume data were obtained at baseline (before OA infusion), at Time 30 (after infusion), and at 30-min intervals for 240 min after OA. At experiment completion, the lungs were removed to determine the wet:dry weight ratios. The control group had RR fixed at 20 breaths/min. The computer group had a RR of 20 +/- 2.3 breaths/min (range, 15 to 27 breaths/min), comprising 369 different RR values with reciprocal changes in VT over 1,089 s before the program looped to repeat itself. There was no difference between groups in the volume of OA infused. By 120 min after lung injury, animals in the computer group had significantly greater PaO2, associated with a lower Qs/QT. Mean airway pressures and mean peak airway pressures were not different in the two groups. By 180 min, respiratory system compliance (Crs) was significantly lower in the control group. The wet:dry lung weight ratios were greater in the control group. Thus, in a porcine model of OA lung injury, computer-controlled mechanical ventilation, which is programmed for biologic variability, resulted in improved blood oxygenation without increasing mean airway pressures when compared with conventional IPPV.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8912782     DOI: 10.1164/ajrccm.154.5.8912782

Source DB:  PubMed          Journal:  Am J Respir Crit Care Med        ISSN: 1073-449X            Impact factor:   21.405


  25 in total

Review 1.  Complex Adaptive Behavior and Dexterous Action.

Authors:  Steven J Harrison; Nicholas Stergiou
Journal:  Nonlinear Dynamics Psychol Life Sci       Date:  2015-10

2.  A novel adaptive control system for noisy pressure-controlled ventilation: a numerical simulation and bench test study.

Authors:  Alessandro Beda; Peter M Spieth; Thomas Handzsuj; Paolo Pelosi; Nadja C Carvalho; Edmund Koch; Thea Koch; Marcelo Gama de Abreu
Journal:  Intensive Care Med       Date:  2009-09-25       Impact factor: 17.440

3.  Effects of recruitment/derecruitment dynamics on the efficacy of variable ventilation.

Authors:  Baoshun Ma; Béla Suki; Jason H T Bates
Journal:  J Appl Physiol (1985)       Date:  2011-03-03

4.  Variable ventilation improves ventilation and lung compliance in preterm lambs.

Authors:  J Jane Pillow; Gabrielle C Musk; Carryn M McLean; Graeme R Polglase; Richard G B Dalton; Alan H Jobe; Béla Suki
Journal:  Intensive Care Med       Date:  2011-05-13       Impact factor: 17.440

Review 5.  Multifractality, Interactivity, and the Adaptive Capacity of the Human Movement System: A Perspective for Advancing the Conceptual Basis of Neurologic Physical Therapy.

Authors:  James T Cavanaugh; Damian G Kelty-Stephen; Nicholas Stergiou
Journal:  J Neurol Phys Ther       Date:  2017-10       Impact factor: 3.649

6.  Bubble continuous positive airway pressure enhances lung volume and gas exchange in preterm lambs.

Authors:  J Jane Pillow; Noah Hillman; Timothy J M Moss; Graeme Polglase; Geoff Bold; Chris Beaumont; Machiko Ikegami; Alan H Jobe
Journal:  Am J Respir Crit Care Med       Date:  2007-04-12       Impact factor: 21.405

Review 7.  What is stochastic resonance? Definitions, misconceptions, debates, and its relevance to biology.

Authors:  Mark D McDonnell; Derek Abbott
Journal:  PLoS Comput Biol       Date:  2009-05-29       Impact factor: 4.475

8.  Variable Ventilation as a Diagnostic Tool for the Injured Lung.

Authors:  Bradford J Smith; Jason H T Bates
Journal:  IEEE Trans Biomed Eng       Date:  2014-04-07       Impact factor: 4.538

9.  Biologically variable ventilation in patients with acute lung injury: a pilot study.

Authors:  Stephen Kowalski; Michael C McMullen; Linda G Girling; Brendan G McCarthy
Journal:  Can J Anaesth       Date:  2013-04-06       Impact factor: 5.063

10.  Combined effects of ventilation mode and positive end-expiratory pressure on mechanics, gas exchange and the epithelium in mice with acute lung injury.

Authors:  Apiradee Thammanomai; Hiroshi Hamakawa; Erzsébet Bartolák-Suki; Béla Suki
Journal:  PLoS One       Date:  2013-01-09       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.