Literature DB >> 8907531

Variation of the pH of the background electrolyte due to electrode reactions in capillary electrophoresis: theoretical approach and in situ measurement.

H Corstjens1, H A Billiet, J Frank, K C Luyben.   

Abstract

Electrode reactions during the electrophoretic process may change the pH of the buffer and subsequently the migration behavior of solutes with resultant loss of reproducibility. A theoretical treatment of pH variations due to electrolytic processes is presented. The choice of buffer appears to have a dramatic influence on the pH variations observed, even if substantial buffer action is expected at the pH chosen. The experimental evaluation of the separation of 4-hydroxy-3-methoxycinnamic acid and 3-hydroxybenzoic acid reveals that the quality of the separation decreases continuously from a baseline separation observed in the first experiment to a comigration of the two solutes (resolution = 0) in the ninth experiment. A pH decrease of about 0.05 pH units accounts for the observed changes in mobility. A novel in situ pH measurement approach is presented, in which the mobility, peak area, and peak height of an indicator dye are related to the pH in the capillary. This enables the identification and quantitation of pH variations during electrophoretic runs: the pH decreases at the anodic side already after the first experiment and pH variations as small as 0.02 pH units can be measured. The variations in peak height appear to be less suited. The calculated pH variations are in close agreement with the ones obtained experimentally.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8907531     DOI: 10.1002/elps.1150170123

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  7 in total

1.  Electroosmotic pump performance is affected by concentration polarizations of both electrodes and pump.

Authors:  Matthew E Suss; Ali Mani; Thomas A Zangle; Juan G Santiago
Journal:  Sens Actuators A Phys       Date:  2011-02-01       Impact factor: 3.407

2.  Microscale pH regulation by splitting water.

Authors:  Li-Jing Cheng; Hsueh-Chia Chang
Journal:  Biomicrofluidics       Date:  2011-11-02       Impact factor: 2.800

3.  Refinement of current monitoring methodology for electroosmotic flow assessment under low ionic strength conditions.

Authors:  Mario A Saucedo-Espinosa; Blanca H Lapizco-Encinas
Journal:  Biomicrofluidics       Date:  2016-06-03       Impact factor: 2.800

4.  Rapid electrotransfer probing for improved detection sensitivity in in-gel immunoassays.

Authors:  Andoni P Mourdoukoutas; Samantha M Grist; Amy E Herr
Journal:  Anal Methods       Date:  2020-10-08       Impact factor: 2.896

5.  Electroosmotic Flow in Microchannel with Black Silicon Nanostructures.

Authors:  An Eng Lim; Chun Yee Lim; Yee Cheong Lam; Rafael Taboryski
Journal:  Micromachines (Basel)       Date:  2018-05-11       Impact factor: 2.891

6.  Dynamic pH and Thermal Analysis of Paper-Based Microchip Electrophoresis.

Authors:  Muhammad Noman Hasan; Ran An; Asya Akkus; Derya Akkaynak; Adrienne R Minerick; Chirag R Kharangate; Umut A Gurkan
Journal:  Micromachines (Basel)       Date:  2021-11-22       Impact factor: 2.891

7.  Development and Validation of a Micellar Capillary Electrophoresis Method for Determination of IFNβ-1b in Lyophilized Formulation of a Biosimilar Product.

Authors:  Manuchehr Dadgarnejad; Hosein Rastegar; Hooshmand Ilka; Maryam Shekarchi; Nooshin Adib; Mahmood Alebouyeh; Nadia Keypour; Shahram Shoeibi; Farzad Kobarfard; Mohammad Reza Fazeli
Journal:  Iran J Pharm Res       Date:  2015       Impact factor: 1.696

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.