Literature DB >> 8906523

Superiority of acceleration and acceleration time over pulsatility and resistance indices as screening tests for renal artery stenosis.

L Burdick1, F Airoldi, I Marana, M Giussani, C Alberti, M Cianci, A Lovaria, S Saccheri, G Gazzano, A Morganti.   

Abstract

OBJECTIVE: To compare the accuracy of four echo-Doppler-derived velocimetric indices (pulsatility and resistance indices, acceleration and acceleration time) in detecting renal artery stenosis in hypertensive patients. PATIENTS AND METHODS: In 73 hospitalized patients with moderate-to-severe hypertension, 18 of whom had normal renal arteries and 55 renal artery stenosis (50-95%) either atherosclerotic (30 cases, five bilateral) or fibromuscular dysplasia (25 cases, two bilateral), we measured the four velocimetric indices using the lateral abdominal approach and sampling Doppler waveforms distally to the stenosis. The diagnostic accuracy of each index was calculated using as cut-off limit the ideal threshold determined with the receiver-operating characteristic curves.
RESULTS: On average all of the indices were altered significantly in arteries with stenosis of both aetiologies with respect to normal arteries, the alterations of pulsatility and resistance indices being, however, less pronounced than those of acceleration and acceleration time, particularly in atherosclerotic stenosis. With the cut-off limits of 0.93, 0.59 and 7.4 m/s2 and 60 ms, respectively, for pulsatility and resistance indices, acceleration and acceleration time, their diagnostic accuracies were 80, 73, 93 and 92%. In stenotic arteries, only the acceleration time was correlated with the degree of arterial narrowing, whereas, in normal arteries, only pulsatility and resistance indices were directly correlated with the age of patients.
CONCLUSIONS: Acceleration and acceleration time are more accurate indices than pulsatility and resistance to screen for renal artery stenosis, probably because their alterations are less attenuated by the counterbalancing effects of age and of atherosclerosis.

Entities:  

Mesh:

Year:  1996        PMID: 8906523     DOI: 10.1097/00004872-199610000-00012

Source DB:  PubMed          Journal:  J Hypertens        ISSN: 0263-6352            Impact factor:   4.844


  4 in total

Review 1.  Usefulness of acceleration time for internal carotid artery origin stenosis.

Authors:  Hirokazu Tamura; Yasuhisa Akaiwa; Kiyoshi Onda
Journal:  Ann Vasc Dis       Date:  2013-07-31

2.  Clinical management of renovascular hypertension: practical recommendations from the Italian Society of Hypertension (SIIA).

Authors:  Chiara Lonati; Alberto Morganti
Journal:  High Blood Press Cardiovasc Prev       Date:  2013-09-11

3.  Computer-assisted detection of tardus parvus waveforms on Doppler ultrasound.

Authors:  Gowthaman Gunabushanam; John D Millet; Erik Stilp; Forrest W Crawford; Robert L McNamara; Leslie M Scoutt
Journal:  Ultrasound       Date:  2017-12-12

4.  Color Doppler Ultrasonography for the Evaluation of Subclavian Artery Stenosis.

Authors:  Jie Zhang; Lijuan Wang; Ying Chen; Sibo Wang; Yingqi Xing; Li Cui
Journal:  Front Neurol       Date:  2022-02-17       Impact factor: 4.003

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.