Literature DB >> 8905858

Percutaneous vs modified phemister epiphysiodesis of the lower extremity.

A C Scott1, B A Urquhart, T E Cain.   

Abstract

Epiphysiodesis of the lower extremity for limb-length discrepancy has been performed on 24 patients by both the modified Phemister and a percutaneous method. The primary complication of epiphysiodesis by both methods was continued growth of the physeal plate (12% and 15%, respectively). Failure of epiphysiodesis was attributed to young skeletal age at surgery in three of five cases. Closer attention to physeal ablation and close follow up should prevent this complication. No angular deformities resulted in any patient. During 16 proximal fibular procedures, there were no neurologic complications. The percutaneous method is preferred due to ease of surgical procedure, minimal incisions, limited disability to the normal extremity, and equal results.

Entities:  

Mesh:

Year:  1996        PMID: 8905858     DOI: 10.3928/0147-7447-19961001-07

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  8 in total

1.  Postoperative growth rate affects time to growth arrest after percutaneous physiodesis: A radiostereometric analysis.

Authors:  Maria Wingstrand; Maria Elfving; Gunnar Hägglund; Henrik Lauge-Pedersen
Journal:  J Child Orthop       Date:  2022-06-30       Impact factor: 1.917

2.  [Epiphysiodesis and hemiepiphysiodesis : Physeal arrest and guided growth for the lower extremity].

Authors:  Madeleine Willegger; Maryse Bouchard; Reinhard Windhager; Alexander Kolb; Catharina Chiari
Journal:  Orthopade       Date:  2022-03-31       Impact factor: 1.004

3.  Gradual Deformity Correction with a Computer-assisted Hexapod External Fixator in Blount's Disease.

Authors:  Pieter H Mare; Leonard C Marais
Journal:  Strategies Trauma Limb Reconstr       Date:  2022 Jan-Apr

4.  Percutaneous epiphysiodesis in the proximal tibia by a single-portal approach: evaluation by radiostereometric analysis.

Authors:  Joachim Horn; Ragnhild Beate Gunderson; Anders Wensaas; Harald Steen
Journal:  J Child Orthop       Date:  2013-06-12       Impact factor: 1.548

5.  Eight plate should not be used for treating leg length discrepancy.

Authors:  Henrik Lauge-Pedersen; Gunnar Hägglund
Journal:  J Child Orthop       Date:  2013-07-03       Impact factor: 1.548

6.  Minimal invasive epiphysiodesis using a modified "Canale"-technique for correction of angular deformities and limb leg length discrepancies.

Authors:  Leonhard E Ramseier; Atul Sukthankar; G Ulrich Exner
Journal:  J Child Orthop       Date:  2009-01-06       Impact factor: 1.548

7.  Negative correlation between extent of physeal ablation after percutaneous permanent physiodesis and postoperative growth: volume computer tomography and radiostereometric analysis of 37 physes in 27 patients.

Authors:  Ragnhild B Gunderson; Joachim Horn; Thomas Kibsgård; Leif Pål Kristiansen; Are Hugo Pripp; Harald Steen
Journal:  Acta Orthop       Date:  2013-06-25       Impact factor: 3.717

8.  Angular deformities after percutaneous epiphysiodesis for leg length discrepancy.

Authors:  Hannah Weinmayer; Anne B Breen; Harald Steen; Joachim Horn
Journal:  J Child Orthop       Date:  2022-08-16       Impact factor: 1.917

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.