Reprogramming pacemakers enhances longevity and is cost-effective.

G H Crossley1, D D Gayle, T W Simmons, W K Haisty, J R Bailey, K Davis-O'Brien, J W Hammon, D M Fitzgerald.   

Abstract

BACKGROUND: Historically, the majority of pulse generators implanted in the United States remain at the nominal programmed settings from the time of implant. While these nominal settings typically allow a sufficient safety margin to prevent later loss of capture with potential chronic threshold rise, the pulse generator with significant use would not be expected to last longer than that predicted by the manufacturer. However, improvements in lead technology have resulted in significantly lower chronic capture thresholds, which would permit lower programmable output settings while still allowing acceptable safety margins. Such changes could result in a significant reduction in long-term battery drain and translate into longer generator life. METHODS AND
RESULTS: One hundred eighty consecutive patients undergoing implantation of permanent pacemakers at our institution were studied to determine the impact of reprogramming on pulse generator longevity and cost. Of these patients, 122 completed 6 months of follow-up at our institution and had pulse generators implanted that were capable of measuring battery current. We compared the estimated longevity based on battery current at nominal settings with that based on settings achieved in follow-up. The final settings were determined by the patient's physician using standard safety margins. The predicted longevity was 6.95 +/- 1.59 years at nominal implant settings and 11.16 +/- 2.71 years at final programmed settings (P < .001). Therefore, reprogramming extends the estimated pulse generator longevity by 4.25 +/- 2.14 years (64%) at a mean cost of $110 per patient (+37 per year extended).
CONCLUSIONS: Reprogramming of permanent pacemakers is efficacious and cost-effective.

Entities:  

Mesh:

Year:  1996        PMID: 8901754

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  4 in total

1.  Feasibility of using the automatic generating system for quartz watches as a leadless pacemaker power source.

Authors:  H Goto; T Sugiura; Y Harada; T Kazui
Journal:  Med Biol Eng Comput       Date:  1999-05       Impact factor: 2.602

2.  Manual vs. automatic capture management in implantable cardioverter defibrillators and cardiac resynchronization therapy defibrillators.

Authors:  Francis D Murgatroyd; Erhard Helmling; Bernd Lemke; Bernd Eber; Christian Mewis; Judith van der Meer-Hensgens; Yanping Chang; Vladimir Khalameizer; Amos Katz
Journal:  Europace       Date:  2010-03-14       Impact factor: 5.214

3.  [Efficiency potential in the pacemaker/implantable cardioverter defibrillator outpatient clinic].

Authors:  A Bauer; J Bauer; M Bauer; K Kelemen; F Voss; J Senges-Becker; S Weretka; H A Katus; R Becker
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2006-03

4.  Personalised reprogramming to prevent progressive pacemaker-related left ventricular dysfunction: A phase II randomised, controlled clinical trial.

Authors:  Maria F Paton; John Gierula; Judith E Lowry; David A Cairns; Kieran Bose Rosling; Charlotte A Cole; Melanie McGinlay; Sam Straw; Rowena Byrom; Richard M Cubbon; Mark T Kearney; Klaus K Witte
Journal:  PLoS One       Date:  2021-12-13       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.