Literature DB >> 10505390

Feasibility of using the automatic generating system for quartz watches as a leadless pacemaker power source.

H Goto1, T Sugiura, Y Harada, T Kazui.   

Abstract

An automatic power-generating system (AGS) which converts kinetic energy into electric energy for quartz watches was tested as a power source for implantable cardiac pacemakers. An automatic power-generating mechanism and a capacitor (0.33 F) were removed from a quartz watch (SEIKO) and encapsulated in a polyvinyl case. Characteristics of the AGS were investigated by acceleration equipment. The capacitor in the AGS was charged to 2.0 V (0.66 J) by placing it on the equipment for about 30 minutes. The equipment has a 2 Hz cycle and generates +/- 1.7 G at the end of each half cycle. The AGS (fully charged to 2.0 V) was used as the power source for a pulse generator circuit built using commercially available CMOS IC. The circuit generated pulses of 0.5 ms width at 1 Hz (60 pulses min-1). The voltage of the AGS was maintained at 1.6 V while it was being charged by the accelerations. The generator supplied pulses of 0.75 V, 1.47 mA through a 510 omega load. With fully charged AGS, the generator was also used to pace a mongrel dog's heart at 140 beats min-1 for 60 minutes. During pacing, the AGS supplied 420 mJ to the circuit and the cardiac muscle. The AGS was placed on the right ventricular wall of the mongrel dog under anaesthesia. Energy of 80 mJ is stored in a capacitor by the heart beating at about 200 beats/min for 30 minutes. Thus the AGS generated 13 microJ per heart beat. This result suggests that the AGS may supply enough energy for use in a cardiac pacemaker.

Entities:  

Mesh:

Year:  1999        PMID: 10505390     DOI: 10.1007/BF02513315

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  8 in total

Review 1.  The electrode-tissue interface: the revolutionary role of steroid elution.

Authors:  H G Mond; K B Stokes
Journal:  Pacing Clin Electrophysiol       Date:  1992-01       Impact factor: 1.976

2.  Reprogramming pacemakers enhances longevity and is cost-effective.

Authors:  G H Crossley; D D Gayle; T W Simmons; W K Haisty; J R Bailey; K Davis-O'Brien; J W Hammon; D M Fitzgerald
Journal:  Circulation       Date:  1996-11-01       Impact factor: 29.690

3.  Influence of internal current and pacing current on pacemaker longevity.

Authors:  A Schuchert; K H Kuck
Journal:  Pacing Clin Electrophysiol       Date:  1994-01       Impact factor: 1.976

4.  High thresholds may alter end-of-life behavior in a dual chamber pacemaker.

Authors:  M Kraus; T A Buckingham; R Candinas
Journal:  Pacing Clin Electrophysiol       Date:  1997-06       Impact factor: 1.976

5.  Useful applications and limits of battery powered implants in functional electrical stimulations.

Authors:  H Lanmüller; M Bijak; W Mayr; D Rafolt; S Sauermann; H Thoma
Journal:  Artif Organs       Date:  1997-03       Impact factor: 3.094

6.  Determinants of dual chamber pulse generators longevity.

Authors:  A Markewitz; D Kronski; A Kammeyer; H Kaulbach; C Weinhold; W Doering; B Reichart
Journal:  Pacing Clin Electrophysiol       Date:  1995-12       Impact factor: 1.976

7.  The automatic threshold tracking pacemaker.

Authors:  T A Preston; D L Bowers
Journal:  Med Instrum       Date:  1974 Nov-Dec

8.  Lithium/carbon monofluoride (Li/CFx): a new pacemaker battery.

Authors:  W Greatbatch; C F Holmes; E S Takeuchi; S J Ebel
Journal:  Pacing Clin Electrophysiol       Date:  1996-11       Impact factor: 1.976

  8 in total
  13 in total

1.  Non-invasive evaluation of the kinematic activity of the intact left ventricle of the heart.

Authors:  L A Bockeria; O L Bockeria; V A Shvartz; L A Glushko; T G Le; A S Satyukova
Journal:  Dokl Biol Sci       Date:  2017-01-06

2.  Energy harvesting through arterial wall deformation: design considerations for a magneto-hydrodynamic generator.

Authors:  Alois Pfenniger; Dominik Obrist; Andreas Stahel; Volker M Koch; Rolf Vogel
Journal:  Med Biol Eng Comput       Date:  2013-02-22       Impact factor: 2.602

Review 3.  Self-powered cardiovascular electronic devices and systems.

Authors:  Qiang Zheng; Qizhu Tang; Zhong Lin Wang; Zhou Li
Journal:  Nat Rev Cardiol       Date:  2020-09-07       Impact factor: 32.419

4.  A sub-cc nonlinear piezoelectric energy harvester for powering leadless pacemakers.

Authors:  M H Ansari; M Amin Karami
Journal:  J Intell Mater Syst Struct       Date:  2017-05-17       Impact factor: 2.569

5.  Experimental investigation of fan-folded piezoelectric energy harvesters for powering pacemakers.

Authors:  M H Ansari; M Amin Karami
Journal:  Smart Mater Struct       Date:  2017-05-02       Impact factor: 3.585

6.  In vivo demonstration of a self-sustaining, implantable, stimulated-muscle-powered piezoelectric generator prototype.

Authors:  B E Lewandowski; K L Kilgore; K J Gustafson
Journal:  Ann Biomed Eng       Date:  2009-08-06       Impact factor: 3.934

Review 7.  Energy harvesting for the implantable biomedical devices: issues and challenges.

Authors:  Mahammad A Hannan; Saad Mutashar; Salina A Samad; Aini Hussain
Journal:  Biomed Eng Online       Date:  2014-06-20       Impact factor: 2.819

8.  A Non-Resonant Kinetic Energy Harvester for Bioimplantable Applications.

Authors:  Mustafa I Beyaz; Hacene C Baelhadj; Sahar Habibiabad; Shyam S Adhikari; Hossein Davoodi; Vlad Badilita
Journal:  Micromachines (Basel)       Date:  2018-05-05       Impact factor: 2.891

Review 9.  Development of implantable medical devices: from an engineering perspective.

Authors:  Yeun-Ho Joung
Journal:  Int Neurourol J       Date:  2013-09-30       Impact factor: 2.835

Review 10.  Power Approaches for Implantable Medical Devices.

Authors:  Achraf Ben Amar; Ammar B Kouki; Hung Cao
Journal:  Sensors (Basel)       Date:  2015-11-13       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.