Literature DB >> 8897144

Improved blood compatibility of segmented polyurethanes by polymeric additives having phospholipid polar groups. I. Molecular design of polymeric additives and their functions.

K Ishihara1, S Tanaka, N Furukawa, K Kurita, N Nakabayashi.   

Abstract

To improve the blood compatibility of a segmented polyurethane (SPU), 2-methacryloyloxyethyl phosphorylcholine (MPC) polymer was blended with the SPU. The MPC was copolymerized with cyclohexyl methacrylate (CHMA) or 2-ethylhexyl methacrylate (EHMA), and the MPC polymers obtained could be dissolved in the same solvent as the SPU (Tecoflex 60). The blended membranes composed of SPU and MPC polymers were prepared by a solvent evaporation method. A small amount of MPC polymer in the blended membrane leached out after immersion in water for 10 days. The X-ray photo electron spectra indicated that the MPC moieties were located at the surface of the SPU membrane blended with poly(MPC-co-CHMA). On the other hand, the poly-(MPC-co-EHMA) was located homogeneously in the SPU membrane. The mechanical properties of the SPU membrane, as determined by tensile stress-strain measurements, changed very little even after addition of the MPC polymers. Blood compatibility of the blended membrane was evaluated by blood-cell adhesion on the surface when the membranes were placed in contact with rabbit whole blood or platelet-rich plasma. The addition of MPC polymer in the SPU membrane dramatically reduced cell adhesion. It is concluded that the blending of the MPC polymer in the SPU membrane is an effective method for imparting nonthrombogenicity.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8897144     DOI: 10.1002/(SICI)1097-4636(199611)32:3<391::AID-JBM12>3.0.CO;2-K

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  11 in total

Review 1.  Effects of the chemical structure and the surface properties of polymeric biomaterials on their biocompatibility.

Authors:  You-Xiong Wang; John L Robertson; William B Spillman; Richard O Claus
Journal:  Pharm Res       Date:  2004-08       Impact factor: 4.200

Review 2.  Technologies for continuous glucose monitoring: current problems and future promises.

Authors:  Santhisagar Vaddiraju; Diane J Burgess; Ioannis Tomazos; Faquir C Jain; Fotios Papadimitrakopoulos
Journal:  J Diabetes Sci Technol       Date:  2010-11-01

3.  Electrospun fibro-porous polyurethane coatings for implantable glucose biosensors.

Authors:  Ning Wang; Krishna Burugapalli; Wenhui Song; Justin Halls; Francis Moussy; Asim Ray; Yudong Zheng
Journal:  Biomaterials       Date:  2012-11-09       Impact factor: 12.479

4.  Evaluation of platelet aggregability during left ventricular bypass using a MedTech MagLev VAD in a series of chronic calf experiments.

Authors:  Taro Kimura; Yoshimasa Yokoyama; Daisuke Sakota; Eiki Nagaoka; Takashi Kitao; Kazuo Takakuda; Setsuo Takatani
Journal:  J Artif Organs       Date:  2012-10-03       Impact factor: 1.731

5.  Enhanced glucose sensor linearity using poly(vinyl alcohol) hydrogels.

Authors:  Santhisagar Vaddiraju; Hardeep Singh; Diane J Burgess; Faquir C Jain; Fotios Papadimitrakopoulos
Journal:  J Diabetes Sci Technol       Date:  2009-07-01

6.  Tailored Synthesis of Nitric Oxide-Releasing Polyurethanes Using O-Protected Diazeniumdiolated Chain Extenders.

Authors:  Melissa M Reynolds; Joseph E Saavedra; Brett M Showalter; Carlos A Valdez; Anna P Shanklin; Bong K Oh; Larry K Keefer; Mark E Meyerhoff
Journal:  J Mater Chem       Date:  2010-01-01

Review 7.  Biocompatible materials for continuous glucose monitoring devices.

Authors:  Scott P Nichols; Ahyeon Koh; Wesley L Storm; Jae Ho Shin; Mark H Schoenfisch
Journal:  Chem Rev       Date:  2013-02-07       Impact factor: 60.622

8.  Biocompatible zwitterionic copolymer networks with controllable swelling and mechanical characteristics of their hydrogels.

Authors:  H Smilkov; I Kamenova; E Kamenska; Ch Betchev; G Georgiev
Journal:  J Mater Sci Mater Med       Date:  2007-12-25       Impact factor: 3.896

9.  Enhancing the sensitivity of needle-implantable electrochemical glucose sensors via surface rebuilding.

Authors:  Santhisagar Vaddiraju; Allen Legassey; Liangliang Qiang; Yan Wang; Diane J Burgess; Fotios Papadimitrakopoulos
Journal:  J Diabetes Sci Technol       Date:  2013-03-01

Review 10.  Emerging synergy between nanotechnology and implantable biosensors: a review.

Authors:  Santhisagar Vaddiraju; Ioannis Tomazos; Diane J Burgess; Faquir C Jain; Fotios Papadimitrakopoulos
Journal:  Biosens Bioelectron       Date:  2009-12-11       Impact factor: 10.618

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.