Literature DB >> 8895632

Characterization of debris adjacent to failed knee implants of 3 different designs.

K Hirakawa1, T W Bauer, B N Stulberg, A H Wilde, L S Borden.   

Abstract

Wear debris particles have been associated with bone resorption and loosening of total joint implants. To characterize the wear particles around failed knee prostheses, tissues adjacent to 47 implants of 3 different designs were evaluated: 29 were posterior cruciate ligament retention type (Group I), 12 were posterior cruciate ligament sacrificing or substituting (Total Condylar, Insall-Burstein), (Group II), and 6 were mobile bearing (posterior cruciate ligament retaining LCS), (Group III). Wear particles were isolated and evaluated using electronic particle quantitation and scanning electron microscopy. The corresponding implants were also evaluated, and the surface damage quantified. The number of particles smaller than 10 microm ranged from 8.9 to 45.8 x 10(9) per gram of tissue (dry weight). Particle number directly correlated with duration of implantation. Group I implants had larger particles, and showed greater surface damage than the other 2 designs. Polyethylene surface damage significantly correlated with particle size more than 10 microm in length. Particle number showed a significant inverse correlation with the thickness of the polyethylene. These results support previous mechanical and retrieval studies suggesting that increased wear may be associated with thinner polyethylene, and there are differing degrees and patterns of wear based on implant design.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8895632     DOI: 10.1097/00003086-199610000-00021

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  5 in total

1.  UHMWPE wear debris and tissue reactions are reduced for contemporary designs of lumbar total disc replacements.

Authors:  Sai Y Veruva; Todd H Lanman; Jorge E Isaza; Daniel W MacDonald; Steven M Kurtz; Marla J Steinbeck
Journal:  Clin Orthop Relat Res       Date:  2015-03       Impact factor: 4.176

2.  Durability of a cruciate-retaining TKA with modular tibial trays at 20 years.

Authors:  John J Callaghan; Mitchell W Beckert; David W Hennessy; Devon D Goetz; Scott S Kelley
Journal:  Clin Orthop Relat Res       Date:  2013-01       Impact factor: 4.176

3.  Clinical, radiological, histological and retrieval findings of Activ-L and Mobidisc total disc replacements: a study of two patients.

Authors:  Shennah Austen; Ilona M Punt; Jack P M Cleutjens; Paul C Willems; Steven M Kurtz; Daniel W MacDonald; Lodewijk W van Rhijn; André van Ooij
Journal:  Eur Spine J       Date:  2012-01-15       Impact factor: 3.134

4.  Routine surveillance of modular PFC TKA shows increasing failures after 10 years.

Authors:  Andrew S Malin; John J Callaghan; Kevin J Bozic; Steve S Liu; Devon D Goetz; Nicholas Sullivan; Scott S Kelley
Journal:  Clin Orthop Relat Res       Date:  2010-03-19       Impact factor: 4.176

5.  Are periprosthetic tissue reactions observed after revision of total disc replacement comparable to the reactions observed after total hip or knee revision surgery?

Authors:  Ilona M Punt; Shennah Austen; Jack P M Cleutjens; Steven M Kurtz; René H M ten Broeke; Lodewijk W van Rhijn; Paul C Willems; André van Ooij
Journal:  Spine (Phila Pa 1976)       Date:  2012-01-15       Impact factor: 3.468

  5 in total